HomeMy WebLinkAboutOrd 3527 05/21/1985 418V
ORDINANCE NO. 3527
AN ORDINANCE TO AMEND ARTICLE III ENTITLED
"SEPTIC TANKS" OF CHAPTER 22
OF THE VILLAGE CODE OF MOUNT PROSPECT, ILLINOIS
BE IT ORDAINED BY THE PRESIDENT AND BOARD OF TRUSTEES OF THE
VILLAGE OF MOUNT PROSPECT, ILLINOIS:
SECTION ONE: Article III entitled "Septic Tanks" of
Chapter 22 of the Village Code of Mount Prospect, Illinois, 1981 is
hereby amended by deleting said Article III in its entirety and by
substituting therefor a new Article III to be entitled "Private
Sewage Disposal" and to read as follows:
"ARTICLE III
PRIVATE SEWAGE DISPOSAL
SECTION:
22.301.
22.302.
22.303.
Requirements
Construction Regulations
Penalty
Section 22.301 Requirements.
A. Every building or structure in the Village used for
residence, business, trade, industry or meeting proposes shall be
equipped with properly constucted and installed adequate sewage
disposal facilities. The plumbing in all'such places shall conform
to the ordinances of the Village and the laws of the State relative
thereto.
B. Any such premises not connected with either a sanitary
sewer system or a combined sewer system, which combined system is in
turn connected to the intercepter system of the Metropolitan
Sanitary District of Greater Chicago, shall be equipped with an
adequate septic tank; such tank shall have a capacity of not less
than seven hundred fifty (750) gallons for each seven (7) or less
persons living or working in such place; and an additional
seventy-five (75) gallons for each person in excess of seven (7);
provided, that the tank in any premises used for meeting purposes
shall have a capacity of not less than one thousand five hundred
(1,500) gallons.
o construct
cesspool, or
sewage.
Except as hereinafter provided, it shall be unlawful
or maintain any privy, privy vault, septic tank,
other facility intended or used for the disposal of
D. Requirements. Before commencement of construction of
a private sewage disposal system, the owner shall first obtain a
written permit signed by the Director of Code Enforcement and pay
all required fees, (provided in Chapter 21, Article VI, Section
21.603 of this Code). The application for such permit shall be made
on a form furnished by the Village which the applicant shall
supplement by any plans, specifications and other information as
deemed necessary by the Director of Code Enforcement.
E. At such time as a public sewer becomes available to a
property served by a private sewage disposal system (septic tank) as
provided in Chapter 22, Article II, Section 22.202 of this Code, a
direct connection shall be made to the public sewer in compliance
with this Section, and any septic tanks, cesspools and similar
private sewage disposal facilities shall be abandoned and filled
with suitable material.
F. The owner shall operate and maintain the private
sewage disposal facility in a sanitary manner at all times and at
expense to the Village.
no
Section 22.302. Construction Regulations
A. The type, capacities, location, and layout of a
private sewage disposal system shall comply with the regulations
contained herein, with all other Village ordinances pertaining
thereto, with the private sewage disposal Code promulgated pursuant
to the Illinois Private Sewage Disposal Licensing Act and with the
regulations of the State of Illinois Environmental Protection
Agency. No permit shall be issued for any private sewage disposal
system employing subsurface soil absorption facilities where the
area of the lot is less than 43,560 square feet. No septic tank or
cesspool shall be permitted to discharge to any natural outlet.
B. Each such tank shall be located at least twenty feet
(20!) from any building, and shall be constructed of twelve gauge
steel monolithic concrete, or of brick or concrete blocks adequately
coated inside so as to be impervious to water. Baffle shall be
located from six inches (6") to nine inches (9") away from the inlet
and outlet and must extend twelve inches (12'~) beneath the sewer
level in the tank. Each tank must be equipped with a manhole or
similar suitably covered opening to permit inspection or cleaning.
C. The feeder sewer from the tank to the laterals of the
disposal field shall be constructed of vitrified bell-and-spigot
tile with cemented joints and shall be laid with a grade of one foot
(1') per one hundred feet (100'); disposal field tile shall be
located at least seventy-five feet (75') distant from any well and
ten feet (10!) from the tank, and thirty feet (30') from any
building used for human habitation. No lateral shall be closer than
five feet (5!) to any lot line. There shall be at least two hundred
feet (200') of disposal field tile, consisting of four inch (4")
drain tile laid within open joints. Disposal tiles shall be laid to
a depth of not more than two feet (2') on a slope not to exceed six
inches (6~) per one hundred feet (100').
D. Backfill in the trench under the tile shall contain at
least six inches (6") of coarse gravel or crushed stone. Each
backfill shall be well tamped.
E. No septic tank or any pipes leading to or from the
same shall be covered unless and until such tank and pipes have been
inspected and found to be in compliance with the ordinances of the
Village and with the State laws pertaining thereto.
-2-
Section 22.303. Penalty. Any person violating any
provision of this Article shall be fined not less than Twenty-Five
Dollars ($25.00) nor more than Two Hundred Dollars ($200.00) for
each offense and a separate offense, shall be deemed committed on
each day during or on which a violation occurs or continues."
SECTION TWO: This Ordinance shall be in full force and
effect upon its passage, approval and publication in pamphlet form
in accordance with law.
PASSED AND APPROVED this21st day of May
, 1985.
AYES: Arthur, Farley, Floros, Murauskis, Van Geem, Wattenberg
NAYS: None
ABSENT:None
ATTEST:
VILLAGE CLERK
-3-