Loading...
HomeMy WebLinkAboutOrd 618 07/15/1958 ORDINANCE NO. (p/f' AN ORDINANCE TO AMEND SECTIONS 22.301 AND 22.302 OF ARTICLE III, CHAPTER 22 OF THE MUNICIPAL CODE OF MOUNT PROSPECT OF 1957 AS AMENDED WHEREAS, it has been determined by the municipal authorities of the Village of Mount Prospect that it is in the interest of public health and welfare to establish in greater detail the septic tank requirements for single family residences substantially as established by the Cook County Department of Public Health, NOW, THEREFORE, BE IT ORDAINED BY THE PRESIDENT AND BOARD OF TRUSTEES OF THE VILLAGE OF MOUNT PROSPECT, COOK COUNTY, ILLINOIS: Section 1: That Section 22.301 of Article III, Chapter 22 of the Municipal Code of Mount Prospect of 1957 as amended, be and the same is hereby amended to and shall hereafte~ read as follows: "Section 22.301 Requirements. Every building or structure in the Village used for residence, business, trade, industry or meeting purposes shall be equipped with properly constructed and installed adequate sewage disposal facilities. The plumbing in all such places shall conform to the ordinances of the Village and the laws of the State relative thereto. "Any such premises not connected with a sani- tary sewer system shall be equipped with an adequate septic tank; such tank shall have a capacity of not less than 750 gallons for each seven or less persons living or working in such place; and an additional 75 gallons for each person in excess of seven; provided that the tank in any premises used for meeting purposes shall have a capacity of not less than 1,500 gallons." Section 2. That Section 22.302 of Article III, Chapter 22 of the Municipal Code of Mount Prospect of 1957 as amended, be and the same is hereby amended to and shall hereafter read as follows: "Section 22.302 Construction Regulations. A. Single Family Residences. All septic tanks for single family residences shall be constructed and conform to the requirements, standards and specifications established by the Cook l''''''' J '1",., . , - 2 - County Department of Public Health, Division of Sanitary Engineering, as set forth in Bulletin No.1, Revised May, 1956, and specifically incor- porating herein by reference Sections 2 through 6 inclusive, and Sections 18 through 51 inclusive, all of which aforesaid sections are made a part hereof. Wherever septic tank requirements are specifically set forth in ordinances of the Vil- lage and not specifically duplicated by the said requirements of the County, they shall apply also to septic tanks for single family residences and any doubt concerning the application thereof shall be considered in favor of requiring the most effec- tive sanitation system. B. For Other Than Single Family Residences. Eacb such tank shall be located at least twenty feet from any building, and shall be constructed of twelve gauge steel, monolithic concrete, or of brick or'concrete blocks adequately coated inside so as to be impervious to water. Baffle shall be located from 6tt to 9tt away from the inlet and out- let and must extend 12" beneath the sewer level in the tank. Each tank must be equipped with a man- hole or similar suitably covered opening to permit inspection or cleaning. The feeder sewer from the tank to the laterals of the disposal field shall be constructed of vitrified bell-and-spigot tile with cemented joints and shall be laid with a grade of one foot per 100 feet; disposal field tile shall be located at least 75 feet distant from any well and ten feet from the tank, and 30 feet from any building used for human habitation. No lateral shall be closer than five feet to any lot line. There shall be at least 200 feet of disposal field tile, consisting of 4tt drain tile laid with~, open joints. Disposal tiles shall be laid to a depth of not more than two feet on a slope not to exceed 61f per 100 feet. Backfill in the trench under the tile shall be at least 6" of coarse gravel or crushed stone. Earth backfill shall be well tamped. No septic tank or any pipes leading to or from the same shall be covered unless and until such tank and pipes have been inspected and found to be in compliance with the ordinances of the village and with the state laws pertaining thereto." Section 3: That this Ordinance shall be in full force and effect from and after its passage, approval and publication according to law. Section 4: That all ordinances or parts of ordi- nances in conflict herewith be and the same are hereby re- pealed, reserving however, to the Village of Mount Prospect 1_.... .. u . "__'"'~"''''~'"''''_'"~''~'_'"~,,''''''''eM~'''_'"_'<_ "'"~"''''-''''-'"''''- 1".... " . , - 3 - any rights which have accrued to it against any person, firm or corporation under any ordinance, or sections of ordinances which may be and are hereby repealed. PASSED this/5 day Of~ APPROVED this /6 day of ~ / , 1958. , 1958. ?J~~lffr~l1~ " tf~~ef .. --. u..e ~ "a-t ~ c;r 7- .,2./-6-[ l-t-, "~ ""."~..,,,, ...._. ..-...""""'."'",-".._,....._.~..._,