Loading...
HomeMy WebLinkAbout8.3 1st reading of AN ORDINANCE GRANTING A PRELIMINARY PLAT OF SUBDIVISION AND CONDITIONAL USE FOR A PRELIMINARY PLANNED UNIT DEVELOPMENT FOR THE PROPERTY LOCATED AT 1200 E. ALGONQUIN ROAD AND 1200 DEMPSTER STREETMr�GauC �'d'+rt;�iect readingSubject Ist of ORDINANCE GRANTING c, PRELIMINARY . OF # D CONDITIONAL USE FOR , . PLANNED UNIT DEVELOPMENT FOR THE PROPERTY L• , 1200 E. ALGONQUIN ROAD 11 DEMPSTER STREET Meeting December 14, 2021 - REGULAR MEETING OF THE MOUNT PROSPECT : • Fiscal Impact Dollar Amount Budget Source Category NEW BUSINESS Type Action Item The Subject Property, also known as the former United Airlines world headquarters, was annexed into the Village in 2017. United Airlines had formerly fully occupied the campus for decades until 2007, when a portion of United's operation moved to downtown Chicago (77 West Wacker Drive). In 2012, United moved all headquarter operations to a new space in downtown Chicago (233 South Wacker Drive, Willis Tower). Since the move, United shifted the campus to IT and minor training operations. In 2013, United constructed a 172,000 square foot data center. The data center is not within the proposed preliminary planned unit developed (PUD) or preliminary plat of subdivision. The Petitioner is proposing a complete redevelopment of the Subject Property which would consist of three (3), 84 megawatt (MW) data centers totaling 566,767 square feet of gross floor area per building. The Petitioner, in conjunction with Commonwealth Edison (ComEd), is also proposing a substation to accommodate the energy use of the data centers. The Petitioner intends to enter into an easement agreement with ComEd, under which ComEd would construct and operate the substation. The data centers would occupy the former United 1 Airlines campus (1200 E. Algonquin Road), and the substation would occupy the existing parking lot to the east (1200 Dempster Street). Of the gross floor area, two of the three data centers would have 31,630 square feet of office space, and the 3rd data center would have approximately 26,600 square feet. Parking: The Petitioner proposes 344 parking stalls, including standard stalls, handicap stalls, and parallel parking stalls. Per Village Code off street parking regulations, 1 stall per 1.5 employees plus 1 space per company vehicle is required, while office space is calculated separately. The Petitioner is anticipating anywhere between 75 to 150 employees per building. Given the employment range, anywhere between 474 and 586 parking stalls are required by Code. Per the Petitioner, the anticipated number of employees includes employees occupying the office space. Additionally, only up to 75% of the total of number of employees would be working during daytime hours. Each data center will require 24/7 surveillance and maintenance staff to be onsite, therefore during peak daytime hours, the parking demand will be significantly less than code requires. At the highest employment projection of 150 employees per building, peak daytime operation will require 338 total parking stalls. Therefore, staff is satisfied with the proposed parking stall allotment. Building Elevations: The Petitioner is proposing a significant level of architectural detail for an industrial building, and proposes several high quality finishes. Each entrance will incorporate a recessed paneling entry way with an all glass facade. Overall, finishes include a large amount of glass, stainless steel that insets into precast panel reveals, white metal panel, anodized aluminum, multiple types of glazing, and a green wall which will hold cables of vines. Each building will be 52' tall with up to 29' tall parapets, for a total height of 81'. The equipment penthouses on each building are 27' tall, which will reach a total height of 79. Rooftop Equipment: Each building rooftop will have 82 chillers and 49 generators to operate the data center at normal capacities and in the event of an emergency or power outage. The generators are to be located in penthouses on two sides of each building. Two generators will be located in a single concrete room. Inlet air will flow from the louvers on the chiller side of the penthouses, across the generator engine casing, and into the inlet side of the radiator fan. The 82 chillers will be screened from view via a aforementioned 29' sound barrier/parapet wall. ComEd sio: To power each of the 84 megawatt (MW) buildings, a new substation is proposed to be constructed and operated by ComEd at the southeast corner of Dempster Street and Linneman Road within the Subject Property. Wiring and utility connections are proposed to be fully underground, and will be tied in from the ComEd utility properties that exist within much of South Mount Prospect, 2 to Linneman Road, and will tie in to the northeast corner of the Subject Property (to the east of Linneman Road). The tallest equipment from the substation will be 86', which is a skinny static mast, but the majority of the equipment will be below 30' in height. Other notable equipment to be located within the substation includes high busses, transformers, and a pre -fabricated metal control enclosure. Extensive landscaping is proposed along the northern area of the substation to screen the substation equipment from surrounding properties. Public Improvements: The proposed development would have pedestrian access via multi use paths on all three frontages, which will connect pedestrians to the retail uses at the intersection of Algonquin Road, Dempster Street and Busse Road, to Kopp Park and the trail within the ComEd right of way adjacent to Kopp Park. In addition, the development will provide direct or indirect pedestrian connections to several Pace bus stops for routes running southbound along Linneman Road and eastbound/westbound along Algonquin Road. These improved connections would directly impact Route 230 (southbound along Linneman Road), and Route 606 (eastbound/westbound along Algonquin Road). While still preliminary at this time, staff and the Petitioner are discussing additional public benefits either on the Subject Property or elsewhere in South Mount Prospect to benefit the surrounding community. Economic pact: As stated in the proposed inducement resolution, but for financial assistance from 6B property tax relief or tax increment financing, this project will not move forward. The project will generate between 225 and 450 permanent, high skilled, high -earning jobs, with an estimated average annual salary of $70,000 and up. Employees include mechanical engineers, electrical engineers, computer engineers, security personnel, maintenance personnel, and real estate property managers. In total, the Petitioner is proposing to invest $2.5 billion (not adjusted for inflation or increase in labor or materials) into the Village. It is estimated that demolition of the existing campus will take up to one year, and each data center takes approximately 18 months to construct. During demolition and construction, the Petitioner estimates up to 900-1,000 construction personnel on-site, totaling approximately 2,116,109 labor hours per data center. If labor hours are multiplied into the construction of all three buildings at typical hourly wages for project management, electrical, mechanical, architectural, structural, and civil related workers & contractors, this accounts for over $630,214,065 total salaries paid throughout the entirety of the project. Each building produces up to 84 megawatts (MW) of energy, which in turn creates utility taxes for the Village. Although preliminary estimates, utility taxes are expected to return up to $1-$2 million annually when the centers are fully KI operational, which in turn allows the Village to upgrade infrastructure and provide other public improvements throughout Mount Prospect. Long Range Planning: The reuse or redevelopment of the United Airlines campus has been a priority for the Village since the property was annexed in 2017. The 2017 Comprehensive Plan, which is a guiding document for future development for the Village, notes this property as a mixed use district' within the future land use map. The primary uses under that category include heavy industrial, manufacturing, and warehousing. Further, the 2017 Comprehensive Plan promotes minimizing the impact on traffic congestion, enhancing walkability, and including streetscape, safe connections, landscape features, and pedestrian amenities for any new development. The proposal meets all of these goals. The 2020 Connect South Mount Prospect Sub -Area Plan offers an opportunity sites map that prioritizes development sites in the study area. The plan prioritizes the Subject Property as the number one opportunity site and recommends warehousing or an industrial park, and notes the existing property is underutilized. The proposal meets all of the plans recommendations for the redevelopment of the Subject Property. In addition, the Village's 2021-2022 Strategic Plan is a working document that is approved by the Village Board and provides staff a collection of goals, policies, and priorities to adhere to and complete for the specified calendar year. The plan identifies creating a direction for the United Airlines Property as a high priority policy agenda item. Impacts on AdjacentProperties: Overall, the Petitioner has demonstrated a commitment to fully abiding by, and meeting all regulations set forth by local, state, and federal entities. Plat of Subdivision: Along with the PUD request, the Petitioner is also proposing a plat of subdivision which would subdivide the main campus of the Subject Property into four lots. The 6 -acre lot east of Linneman Road would remain its own lot, and in the future be owned and operated by ComEd. Each of the three buildings would occupy their own lots, with the 4th lot as the common area of the project. Because each data center parcel is proposed to be landlocked, prior to final PUD and final plat of subdivision approval, the Village is requiring submittal of a covenants, conditions, restrictions, and reciprocal easements document to ensure the orderly and harmonious function of the proposed lots should they be sold off in the future. Staff and the Village's legal team have reviewed the preliminary plat, and the plat meets the applicable regulations set forth by the Village Code. 4 Recommendation: Staff has reviewed the Petitioner's request for a conditional use for a preliminary PUD and preliminary plat of subdivision and is supportive of the requests. The proposal takes advantage of an underutilized site in South Mount Prospect, and is a high quality light industrial development. The long term benefit to the Village, specific to upgrading Village owned infrastructure in South Mount Prospect is significant, and will positively impact residents and existing businesses within South Mount Prospect. The proposed use is compatible to the area, with a data center located directly to the west of the Subject Property, and the development meets all long range planning and policy documents related to the site. Planning oinCommission Hearing: At the Planning & Zoning Commission hearing on December 9, 2021, the Commission voted to recommend approval of the request 5-0. Testimony from a member of the public regarding potential noise was presented, with the petitioner citing the acoustic study and related sound attenuation will be completed to meet code. The Petitioner further stated they will meet all Village Code requirements as it relates to noise and emissions, and will ensure proper mitigation to not impact adjacent properties. The Petitioner has submitted a letter requesting to waive the 2nd reading of the case. STAFF RECOMMENDATION: Staff recommends approval of the preliminary plat of subdivision and preliminary planned development with waiver of second reading. Alternatives 1. Approve a preliminary plat of subdivision title ""Mount Prospect Technology Campus Preliminary Plat of Subdivision" and; 2. A Conditional Use for a preliminary planned unit development (PUD) consisting of three (3) data centers, each totaling a gross square footage of five hundred sixty six thousand seven hundred sixty seven (566,767) square feet, three hundred forty four (344) parking stalls, and a ComEd operated substation, subject to the conditions listed in the staff report. 3. Discretion of the Village Board. Staff Recommendation Approval of: 1. A preliminary plat of subdivision titled "Mount Prospect Technology Campus Preliminary Plat of Subdivision" and; 2. A Conditional Use for a preliminary planned unit development (PUD) 5 consisting of three (3) data centers, each totaling a gross square footage of five hundred sixty six thousand seven hundred sixty seven (566,767) square feet, three hundred forty four (344) parking stalls, and a CornEd operated substation, subject to the conditions listed in the staff report. ATTACHMENTS: Staff Report. pdf Preliminary Plat of Subdivision.pdf Minutes.pdf Waive 2nd Reading Request.pdf Plans final. pdf Administrative—Content, Acoustics and Stormwater Mgmt Studies, Substation Documents.pdf Traffic Impact Study 1200 Algonquin Rd.pdf Geotechnical Engineering Report 1200 E. Algonquin.pdf Redline - PUD Ordinance (003).pdf 11 VILLAGE OF MOUNT PROSPECT 50 S. Emerson Street, Mount Prospect, IL 60056 STAFF REPORT FROM THE DEPARTMENT OF Community Development William J. Cooney, AICP Connor Harmon Director of Community Development Senior Development Planner DATE: December "d ._. __ ... w __ __ ._..__. er 2 2021 CASE NUMBER PZ -16-21 PUBLIC HEARING DATE December 9th, 2021 BRIEF SUMMARY OF REQUEST APPLICANT/PROPERTY OWNER CloudHQ, LLC, United Airlines, Inc. PROPERTY ADDRESS/LOCATION 1200 E. Algonquin Road, 1200 Dempster Street CloudHQ, LLC, the "Petitioner", is proposing to demolish the existing office campus and adjacent parking lot to construct three (3) data centers and a new substation in conjunction with Commonwealth Edison (ComEd). Each data center consists of 566,767 square feet of gross floor area (GFA), and is 52' tall with penthouse equipment and roof parapets that will bring the total height of each building to 81'. The Village Code requires conditional use approval for a Planned Unit Development (PUD) for proposed developments that have more than one principle building on a lot of record. The Petitioner is requesting preliminary PUD and preliminary plat of subdivision approval. The Subject Property is zoned 1-1 Limited Industrial, and the Village's Comprehensive Plan designates the Subject Property as a mixed use district, with primary uses including heavy industrial, manufacturing, warehousing, office, and research. The proposed use complies with the characteristics of the Comprehensive Plan. Staff is supportive of the request. 2020 Aerial Image 2021 Village of Mount Prospect Zoning Map EXISTING EXISTING LAND SURROUNDING ZONING & LAND USE SIZE OF ZONING USE/SITE North: R -X Single Family Residential, R-4 Multi- PROPERTY 1-1 Limited IMPROVEMENTS Family Residential, residential 43.58 acres Industrial Office Campus, Parking Lot East: 1-1 Limited Industrial, light industrial (campus), (former United Airlines South: 1-1 Limited Industrial, light industrial 6.14 acres .........�..wor headquarters) q Industrial, data center West: 1-1 Limited Indu .... .. ..._ .v ............ (parking lot) _� ___........ . STAFF RECOMMENDATION APPROVE PRCIVE WITH CONDITIC?I DENY 7 The Subject Property, also known as the former United Airlines world headquarters, was annexed into the Village in 2017. United Airlines had formerly fully occupied the campus for decades until 2007, when a portion of United's operation moved to downtown Chicago (77 West Wacker Drive). In 2012, United moved all headquarter operations to a new space in downtown Chicago (233 South Wacker Drive, Willis Tower). Since the move, United shifted the campus to IT and minor training operations. In 2013, United constructed a 172,000 square foot data center. The data center is not within the proposed preliminary planned unit developed (PUD) or preliminary plat of subdivision. The Petitioner is proposing a complete redevelopment of the Subject Property which would consist of three (3), 84 megawatt (MW) data centers totaling 566,767 square feet of gross floor area per building. The Petitioner, in conjunction with Commonwealth Edison (ComEd), is also proposing a substation to accommodate the energy use of the data centers. The Petitioner intends to enter into an easement agreement with ComEd, under which ComEd would construct and operate the substation. The data centers would occupy the former United Airlines campus (1200 E. Algonquin Road), and the substation would occupy the existing parking lot (1200 Dempster Street). Of the gross floor area, 2 of the 3 data centers would have 31,630 square feet of office space, and the 3rd data center would have approximately 26,600 square feet. Site Plan: As previously mentioned, each data center would occupy more than 560,000 square feet of gross floor area. In addition to the data center space, each building would consist of a truck loading dock, associated parking, and office/administrative space. Access to the site would be served by a right in, right out, truck only access on Dempster Street, a full access on Linneman Road, and a full access on Algonquin Road. Each full access area will have a security booth and require security clearance to enter. Site detention will be accommodated throughout the property. An 8' security fence would also surround the entire data center site. An 11' security fence is proposed to surround the substation area. Although the request is for PUD approval, the data centers meet applicable setback regulations per the 1-1 Limited Industrial zoning district. Similarly, while the PUD tool allows for unified zoning control, the proposal is within the maximum lot coverage requirement for the 1-1 district (maximum 75% impervious surface), at 68.1%. Parking: The Petitioner proposes 344 parking stalls, including standard stalls, handicap stalls, and parallel parking stalls. Per Village Code off street parking regulations, 1 stall per 1.5 employees plus 1 space per company vehicle is required, while office space is calculated separately. The Petitioner is anticipating anywhere between 75 to 150 employees per building. Given the employment range, anywhere between 474 and 586 parking stalls are required by Code. Per the Petitioner, the anticipated number of employees includes employees occupying the office space. Additionally, only up to 75% of the total of number of employees would be working during daytime hours. Each data center will require 24/7 surveillance and maintenance staff to be onsite, therefore during peak daytime hours, the parking demand will be significantly less than code requires. At the highest employment projection of 150 employees per building, peak daytime operation will require 338 total parking stalls. Therefore, staff is satisfied with the proposed parking stall allotment. Building Elevations: The Petitioner is proposing a significant level of architectural detail for an industrial building, and proposes several high quality finishes. Each entrance will incorporate a recessed paneling 2 C3 entry way with an all glass fagade. Overall, finishes include a large amount of glass, stainless steel that insets into precast panel reveals, white metal panel, anodized aluminum, multiple types of glazing, and a green wall which will hold cables of vines. Each building will be 52' tall with up to 29' tall parapets, for a total height of 81'. The equipment penthouses on each building are 27' tall, which will reach a total height of 79'. Rooftop Equipment: Each building rooftop will have 82 chillers and 49 generators to operate the data center at normal capacities and in the event of an emergency or power outage. The generators are to be located in penthouses on two sides of each building. Two generators will be located in a single concrete room. Inlet air will flow from the louvers on the chiller side of the penthouses, across the generator engine casing, and into the inlet side of the radiator fan. The 82 chillers will be screened from view via a 29' sound barrier/parapet wall. Accessory Structures: Several accessory structures are proposed on the roof of each building, at grade level, and below grade in the event of an emergency or power outage to keep the data centers and electrical infrastructure operating. A total of 18 battery powered thermal storage tanks, and 3 fuel oil polisher sheds are proposed at grade level. A total of 30 underground diesel fuel storage tanks are proposed. Each underground tank will be between 15' and 20' below grade. The thermal storage tanks are required to help cool the data center's system, including its servers. In the event of an outage, the pumps utilize water and a 30% propylene glycol solution within the tanks to cool the systems until the backup generators can run the chillers that ordinarily cool the system. The at -grade tanks are proposed to be 44.75' tall to the top of the ladder, and 13.17' wide. The fuel oil polisher sheds are a supplement to the rooftop generators in case of a power outage. During a power outage, the backup generators provide electricity to the system. As the generators run on diesel fuel, and outages are rare, the fuel must be periodically polished to remove water (that naturally accumulates from humidity) and prevent sediments from settling. Within each shed are mechanical pumps, valves, and a fuel oil polisher. The pumps periodically cycle the fuel from the underground fuel tanks to the fuel oil polisher to remove the water from the fuel. Similarly, below grade, storage tanks hold diesel fuel in the event of a power outage. Total fuel storage accounts for up to a 48 hour power outage. The below grade storage tanks are proposed to be 10.33' wide by 24.1' long, and are made of fabricated materials specifically tested for diesel fuel storage. ComEd Substation: To power each of the 84 megawatt (MW) buildings, a new substation is proposed to be constructed and operated by ComEd at the southeast corner of Dempster Street and Linneman Road within the Subject Property. Wiring and utility connections are proposed to be fully underground, and will be tied in from the ComEd utility properties that exist within much of South Mount Prospect, to Linneman Road, and will tie in to the northeast corner of the Subject Property (to the east of Linneman Road). The tallest equipment from the substation will be 86', which is a skinny static mast, but the majority of the equipment will be below 30' in height. Other notable equipment to be located within the substation includes high busses, transformers, and a pre -fabricated metal control enclosure. Extensive landscaping is proposed along the northern area of the substation to screen the substation equipment from surrounding properties. Landscaping: The Petitioner submitted a landscape plan which is intended to screen the proposed buildings 3 9 and substation from the adjacent residential as much as feasibly possible. In total, 257 new trees, 2,323 new shrubs, and over 500,000 square feet of sod is proposed onsite. The southeast corner of the site will feature a circular path, bench seating, and a thoughtful landscape mix. In conjunction with the Public Works Department, as many existing trees will be preserved as possible. Traffic: The proposed used generally has a much lower employee count compared to other uses utilizing the same amount of gross floor area. Site access is clear and will be well defined by signage. Primary access for all in -bound trucks is proposed off Algonquin Road via a full access entrance and exit. Secondary passenger vehicle access will be provided from Linneman Road. Trucks will be allowed to exit only through the Linneman Road access. The right in, right out access on Dempster Street is intended to be for emergency use only, and will be controlled by an emergency gate. The previous United Airlines headquarters at one point housed over 3,500 employees. The proposed use will have a considerably lower impact on traffic in the surrounding area. The Petitioner also prepared a traffic impact study to evaluate the proposed use's impact on the areas roadways. The traffic study suggests the project will have little effect upon the operations of the area roadway network. The study also proposes the following recommendations: • A dedicated right -turn lane be installed on Algonquin Road going westbound at the proposed site access driveway. • Painted medians along Linneman Road and Algonquin Road be restriped to provide a separate left turn lane (Linneman Road) and a two-way left turn lane on Algonquin Road. • Stop signs be installed for existing traffic at both site access driveway. • Provide a single wide inbound lane and two outbound lanes, striped for separate right and left turn lanes at the Algonquin Road access point. Public Improvements: The proposed development would have pedestrian access via multi use paths on all three frontages, which will connect pedestrians to the retail uses at the intersection of Algonquin Road, Dempster Street and Busse Road, to Kopp Park and the trail within the ComEd right of way adjacent to Kopp Park. In addition, the development will provide direct or indirect pedestrian connections to several Pace bus stops for routes running southbound along Linneman Road and eastbound/westbound along Algonquin Road. These improved connections would directly impact Route 230 (southbound along Linneman Road), and Route 606 (eastbound/westbound along Algonquin Road). While still preliminary at this time, staff and the Petitioner are discussing additional public benefits either on the Subject Property or elsewhere in South Mount Prospect. Phasing: Should the project be approved, the Petitioner is projecting that permit review and approval by all applicable entities would not be completed until mid -2022. Further, demolition of the existing campus would not be completed until the 4th quarter of 2022, and the Petitioner plans to construct one data center at a time, the first being the southwestern building. Each building would take 18 months to construct, thus the first data center is proposed to be operational by the end of the first quarter of 2024. The 3rd data center is projected to be completed and operational by the 41h quarter of 2026. Economic Impact: As noted previously, each building will create between 75 and 150 permanent, high skilled, high -earning jobs, with an estimated average annual salary of $70,000 and up. Employees include 4 10 mechanical engineers, electrical engineers, computer engineers, security personnel, maintenance personnel, and real estate property managers. In total, the Petitioner is proposing to invest $2.5 billion (not adjusted for inflation or increase in labor or materials) into the Village. During construction, it is estimated that demolition of the existing campus will take up to one year, and each data center takes approximately 18 months to construct. During demolition and construction, the Petitioner estimates up to 900-1,000 construction personnel on-site, totaling approximately 2,116,109 labor hours. If labor hours are multiplied into the construction of all three buildings at typical hourly wages for project management, electrical, mechanical, architectural, structural, and civil related workers & contractors, this accounts for over $630,214,065 total salaries paid throughout the entirety of the project. Each building produces up to 84 megawatts (MW) of energy, which in turn creates utility taxes for the Village. Although preliminary estimates, utility taxes are expected to return up to $1-$2 million annually when the centers are fully operational, which in turn allows the Village to upgrade infrastructure and provide other public improvements throughout Mount Prospect. Long Range Planning: The reuse or redevelopment of the United Airlines campus has been a priority for the Village since the property was annexed in 2017. The 2017 Comprehensive Plan, which is a guiding document for future development for the Village, notes this property as a 'mixed use district' within the future land use map. The primary uses under that category include heavy industrial, manufacturing, and warehousing. Further, the 2017 Comprehensive Plan promotes minimizing the impact on traffic congestion, enhancing walkability, and including streetscape, safe connections, landscape features, and pedestrian amenities for any new development. The proposal meets all of these goals. The 2020 Connect South Mount Prospect Sub -Area Plan offers an opportunity sites map that prioritizes development sites in the study area. The plan prioritizes the Subject Property as the number 1 opportunity site and recommends warehousing or an industrial park, and notes the existing property is underutilized. The proposal meets all of the plans recommendations for the redevelopment of the Subject Property. Finally, the Village's 2021-2022 Strategic Plan is a working document that is approved by the Village Board and provides staff a collection of goals, policies, and priorities to adhere to and complete for the specified calendar year. The plan identifies creating a direction for the United Airlines Property as a high priority policy agenda item. Impacts on Adjacent Properties: Overall, the Petitioner has demonstrated a commitment to fully abiding by, and meeting all regulations set forth by local, state, and federal entities. Below is an assessment on the proposed impacts: Noise: The Petitioner submitted an acoustic and noise study, which analyzed the noise from the rooftop chillers and generators on each of the three proposed buildings. Village Code allows sound frequencies at ten different octave band frequencies, measured in decibels (dB). dB sound pressure levels are unweighted, dBA levels are "A" weighted according to the weighting curves to approximate the way humans hear sound or noise. To properly attribute weighted decibel levels to Village Code standards, logarithmically, limits are weighted to a daytime dBA of 56, and a nighttime dBA of 52. Village Code also restricts any noise level 5 11 within any 1-1 limited industrial property from exceeding 71 dBA. For reference, 52-56 dBA sound is similar in intensity to an electric fan, hair dryer, or a running refrigerator. The Petitioner has not requested to waive any noise requirement set forth by Village Code. Noise muffling measures the Petitioner has proposed includes sound wall barriers, penthouses for generators, an insulated metal panel system in the penthouses, "hospital -grade" silencers for the generator exhaust pipes, 5' parallel baffle silencers within the penthouses, and 12" acoustical louvers on the sides of the penthouses. While this request is for preliminary approval, the Petitioner is committed to meeting all regulations set forth by the Village. During final PUD approval, the Petitioner will provide more specific design details and exhibits showing all proposed noise generating equipment will be properly mitigated. Emissions: The proposed generators are diesel powered that emit particulate matter when operable. The Petitioner is proposing to install a selective catalytic reduction (SCR) system on each generator that will reduce overall emissions. Additionally, the Petitioner will use a 32.5% concentrated urea solution (urea is a non -hazardous substance stored in underground tanks) to remove nitrous oxide from the exhaust. To accomplish this, 6 underground urea tanks are proposed. The generators are only used in the event of an emergency or power outage, however each generator will be periodically run for testing 5-8 hours per year. The Petitioner is also required to obtain a permit from the Illinois Environmental Protection Agency (TEPA) and will have to meet all of their established criteria for allowable emissions from the generators. Plat of Subdivision: Along with the PUD request, the Petitioner is also proposing a plat of subdivision which would subdivide the main campus of the Subject Property into 4 lots. The 6 -acre lot east of Linneman Road) would remain its own lot, and in the future be owned and operated by ComEd. Each of the three buildings would occupy their own lots, with the 4th lot as the common area of the project. Because each data center parcel is proposed to be landlocked, prior to final PUD and final plat of subdivision approval the Village is requiring submittal of a covenants, conditions, restrictions, and reciprocal easements document to ensure the orderly and harmonious function of the proposed lots should they be sold off in the future. Staff and the Village's legal team have reviewed the preliminary plat, and the plat meets the applicable regulations set forth by the Village Code. COMPATIBILITY WITH VILLAGE CODE The standards for conditional uses are listed in Section 14.203.F.8 of the Village Zoning Ordinance and include seven specific findings that must be made in order to approve a conditional use. The following list is a summary of these findings: • The conditional use will not have a detrimental impact on the public health, safety, morals, comfort or general welfare; • The conditional use will not be injurious to the use, enjoyment, or value of other properties in the vicinity or impede the orderly development of those properties; • There is adequate provision for utilities, drainage, and design of access and egress to minimize congestion on Village streets; and • The request is in compliance of the conditional use with the provisions of the Comprehensive Plan, Zoning Code, and other Village Ordinances. The Petitioner states that the proposed development will not be detrimental to, or endanger the public health, safety, morals, comfort, or general welfare. The Petitioner states further that the proposed conditional use will not adversely impact the value or use of any other property, and that it is a compatible use given the surrounding area. The Petitioner further states the proposed conditional use is self-contained 12 within the Subject Property, and will not impede orderly development or improvement in the surrounding area. Additionally, the Petitioner states the proposed development is consistent with the Village's long range plans and policy agendas, and that besides the exceptions requested, the proposal will conform to the applicable regulations set forth in the 1-1 Limited Industrial zoning district. Staff has reviewed the Petitioner's request for a conditional use for a preliminary PUD and preliminary plat of subdivision and is supportive of the requests. The proposal takes advantage of an underutilized site in South Mount Prospect, and is a high quality light industrial development. The long term benefit to the Village, specific to upgrading Village owned infrastructure in South Mount Prospect is significant, and will positively impact residents and existing businesses within South Mount Prospect. The proposed use is compatible to the area, with a data center located directly to the west of the Subject Property, and the development meets all long range planning and policy documents related to the site. Staff finds that the proposal meets the conditional use standards and applicable subdivision standards in the Village Code, and that granting such request would be in the best interest of the Village. Staff recommends that the Planning & Zoning Commission make a motion to adopt staff's findings as the findings of the Planning and Zoning Commission and recommend approval of the following motion: 1. A preliminary plat of subdivision title "Mount Prospect Technology Campus Preliminary Plat of Subdivision"; 2. A Conditional Use for a preliminary planned unit development (PUD) consisting of three (3) data centers, each totaling a gross square footage of five hundred sixty six thousand seven hundred sixty seven (566,767) square feet, three hundred forty four (344) parking stalls, and a ComEd operated substation, subject to the following conditions of approval: a. Submittal of landscape, irrigation, and photometric plans that comply with Village codes and regulations; b. Development in general conformance with the site plan prepared by Corgan dated November 12, 2021; c. Compliance with all applicable development, fire, building, and other Village Codes and regulations; d. Petitioner shall provide documentation to the Village that the proper IEPA and OSHA permits have been obtained prior to any certificate of occupancy issuance; e. Prior to final PUD and final plat of subdivision approval, Petitioner shall provide the Village a copy of the covenants, conditions, restrictions, and reciprocal easements document; ' f. All proposed noise, vibration, and particulate matter levels shall meet Village Code requirements; g. Prior to final PUD and final plat of subdivision approval, a donation to the Mount Prospect Park District shall be agreed to for public improvements to park district facilities benefiting the surrounding neighborhoods; h. Petitioner shall provide all off-site and public improvements as required by Village Code; L The existing access road between ORD1 to the north and the property to the west (1540 W. Algonquin Road) shall be eliminated, and a turn -around area shall be constructed within the 1540 W. Algonquin Road property; j. Petitioner shall provide a complete building code analysis during the permitting process 7 13 which shall comply with the requirements set forth in the adopted building codes and amendments as adopted by the Village; k. Petitioner shall obtain all necessary permits for other entities including, but not limited to, IDOT, IEPA, Metropolitan Water Reclamation District (MWRD), Cook County, Army Corps of Engineers, and the Illinois Department of Natural Resources (IDNR); I. Petitioner shall comply with local, state, and federal regulations regarding the abatement of asbestos; m. All signs shall be submitted, reviewed, and approved during the permitting process. All signs shall conform to Village Code unless otherwise noted in the PUD request. The Village Board's decision is final for this case, ADMINISTRATIVE CONTENT "" PLANS OTHER or'�ing Request Application, Responses to Plat of Survey, Site Plan, to (Supp@mer�ta8 Information, Public Standards, etc.... Comments Received, etc.,..) Iconcur: William i C oney, AIC Director of Community Development N. 14 M tu q "W- D 0 A _p- -p q- M NO Fa E, jVL2L M.LO..oM to 0 H z Ug s M ,60"a N.ZO,-WN 9M0N Z 0 mommLw M� jo ts p— — — — — — cm mo 61 "MNM .59P9£M.ZO13FWN — — — — — — — *6ZFe N.ZO 9P.WN �En_ 'L P 3.. ay zm.*Ios z 'm o z 0" o v) oo, 3- z w [L z m tj z z oom a o oq,jjt, M.VZ,V*AON Oc ZE Im co ­Hw all AoMN OW" .11 — — — — — - — — — — — — 9s9 M.jZj,*JON -TM 3, 1�0 Wz. R.- p€ a w pl. P­ ux MINUTES OF THE REGULAR MEETING OF THE PLANNING & ZONING COMMISSION CASE NO. PZ -16-21 Hearing Date: December 9, 2021 PROPERTY ADDRESS: 1200 E. Algonquin Road, 1200 Dempster Street PETITIONER: CloudHQ, LLC PUBLICATION DATE: November 24, 2021 REQUEST: Preliminary Plat of Subdivision CU: Preliminary Planned Unit Development (PUD) MEMBERS PRESENT: Thomas Fitzgerald William Beattie Walter Szymczak Joseph Donnelly Donald Olsen MEMBERS ABSENT: Norbert Mizwicki Lisa Griffin STAFF MEMBERS PRESENT: Bill Cooney, AICP — Director of Community Development Connor Harmon —Senior Development Planner Ann Choi — Development Planner Valeria Tarka — Planning Intern INTERESTED PARTIES: Cloud HQ, LLC, Commonwealth Edison Company (ComEd) 1 Chairman Donnelly called the meeting to order at 7:01 PM. Commissioner Beattie made a motion seconded by Commissioner Szymczak to approve the minutes from the Planning and Zoning Commission meeting on November 11, 2021. The minutes were approved 4-1. Chairman Donnelly introduced case, PZ -16-21 1200 E. Algonquin Road and 1200 Dempster Street (Subject Property), for a conditional use for a preliminary plat of subdivision and a preliminary planned unit development (PUD). The case is Village Board final. Mr. Harmon gave a brief description of the Subject Property and indicated the existing conditions of the Subject Property and history of the former United Airlines world headquarters location and past relocation of the headquarters. He indicated in 2012 a new data center was constructed to the immediate west of the Subject Property, and that the western property will continue to be owned by United, but is not part of the project or Subject Property. Mr. Harmon continued and explained that the Petitioner is proposing to construct three data centers on the main campus, and new substation, owned and operated by ComEd, on the parcel across the street 16 from Linneman Road, also known as 1200 Dempster Street, which is part of the Subject Property. Mr. Harmon stated that the centers will consist of office space, a truck dock, and several accessory structures. Mr. Harmon went on to say 344 parking stalls are proposed, and that staff is comfortable with the proposed parking ratio given the lighter intensity use. Mr. Harmon explained the proposed renderings and design of the building, and indicated materials would include stainless steel, glass, and white metal panel, among other building materials. He then stated the proposed height of each building with the included parapet wall would be 81'. Mr. Harmon provided details on the proposed landscape plan, stating considerable landscaping will be installed to buffer the adjacent properties as feasibly as possible. Mr. Harmon stated the Petitioner also plans to improve off site areas as required by Village Code. Mr. Harmon explained the accessory structures of each principle building, indicating that each building will have 6 thermal storage tanks, one oil polisher shed, and 10 underground diesel fuel storage tanks. Mr. Harmon further explained in detail the proposed ComEd substation, stating that most of the equipment will not exceed 30' in height, and that the highest mast will reach 86' in height. Mr. Harmon explained the financial impact of the project, stating the Petitioner plans to invest $2.5 billion into property, and that future EAV value will equal roughly 5% of the total EAV of the Village. Mr. Harmon stated that up to 1,000 construction jobs will be created throughout construction, and up to 450 full time jobs will be created once the buildings are operational. Mr. Harmon stated that the long range plans approved, and published by the Village support the development, and that the Village is in support of the requests. Mr. Harmon concluded by explaining that this hearing is for preliminary approval, meaning the Petitioner will have to come through entitlements again to receive final approval, and that preliminary approval approves the use and general design of the project. Mr. Harmon stated staff recommends that the Planning and Zoning Commission make a motion to adopt staff's findings as the findings of the Planning and Zoning Commission and recommend approval of the following motion: 1. A preliminary plat of subdivision title "Mount Prospect Technology Campus Preliminary Plat of Subdivision"; 2. A Conditional Use for a preliminary planned unit development (PUD) consisting of three (3) data centers, each totaling a gross square footage of five hundred sixty six thousand seven hundred sixty seven (566,767) square feet, three hundred forty four (344) parking stalls, and a Com Ed operated substation, subject to the conditions listed in the staff report. He stated the Village Board's decision is final for the case. Chairman Donnelly swore in Matt Norton, 330 N. Wabash St, Chicago, IL. Mr. Norton introduced the project team, and introduced Brett Burnette as the development manager. 17 Chairman Donnelly swore in Brett Burnette, 3855 Inverness Road, Fairfax, VA. Mr. Burnette started his presentation by explaining CloudHQ, which is a multi -national developer of data centers that is headquartered in Washington D.C. Mr. Burnette stated CloudHQ has developed several existing data centers, including a project in Elk Grove Village, and stated the team is excited to come into Mount Prospect. Mr. Burnette further stated that the group has been told no noise complaints have been filed or are known to the Petitioner regarding the existing United Airlines data center to the west. Mr. Burnette stated the proposed buildings were designed to mitigate impacts to adjacent neighbors, including placing the office component of the northeastern building, which has a lower height, nearest the residential across Dempster Street. Mr. Burnette explained the building materials, which are of high quality and depict thoughtful design. Mr. Burnette touched on the landscape plan, and indicated landscaping is designed to screen the buildings and substation as best as possible. Mr. Burnette then stated CloudHQ plans to donate funds to the Mount Prospect Park District for additional public improvements and benefits to the community. Mr. Burnette indicated the benefits to the community from the project which include an increased property tax collection, increase in utility tax collection, and the limited demand on public services. Mr. Burnette stated CloudHQ will only hire union workers related to the construction phase of the project. Mr. Burnette went on to say the economic impact to surrounding businesses will be significant, and businesses will attract construction workers and eventual full time workers. Mr. Burnette explained the full time workers will be high earning jobs, and that these workers will likely live in or near Mount Prospect. Mr. Burnette explained the financial investment of the project, which as stated previously is $2.5 billion, and he stated taxes will add millions to Mount Prospect. Mr. Burnette further explained the limited traffic projection on the site, and concluded with stating that given the benefits this proposal will bring to the community, CloudHQ believes this use is an ideal fit for the location. Mr. Norton explained how the proposal meets long range planning documents published and approved by the Village, including the 2017 Comprehensive Plan, and the 2020 CONNECT South Mount Prospect Sub -Area Plan. Mr. Norton explained that both documents recommend an industrial park, or warehousing uses on the Subject Property, and support the development. Mr. Norton further explained the development will increase employment opportunities for the Village, and expand the tax base for the Village. Mr. Norton continued to state the proposal is in the public's best interest as Petitioner plans to redevelop an underutilized property, and stated there is a large demand for the high quality data centers. Mr. Norton concluded by stating the Petitioner will mitigate and meet all Village Codes in terms of noise and adjacent neighbor impacts. Commissioner Fitzgerald asked about the construction phasing of the project. Mr. Burnette stated demo will take 6-9 months, and construction of the buildings will depend on approvals on market demand, but the goal is to finish demo by the end of 2022, and construct the first 18 building thereafter. He stated each building takes 1.5-2.5 years to complete, and construction will be one building at a time, unless demand increases. Commissioner Fitzgerald asked if the United Airlines underground area will be demolished as well. Mr. Burnette stated yes. Commissioner Olsen asked if all the power comes from the proposed substation. Mr. Burnette stated yes, and the goal is to use the existing transmission line underground. Mr. Burnette stated CloudHQ would own the substation, and that ComEd would operate it. Commissioner Beattie asked what customers will locate within the proposed data centers. Mr. Burnette stated the largest data companies in the world will likely locate there. Chairman Donnelly asked what tenants occupy other CloudHQ buildings. Mr. Burnette stated Microsoft and Facebook occupy some other data centers. Chairman Donnelly swore in Robert Galler, 1810 W. Hatherleigh Court, Mount Prospect, IL. Mr. Galler asked several questions, including how much money is the park district being donated, what does EAV stand for, and commented that the proposal is a threat to foreign entities. Chairman Donnelly asked if he has any current noise complaints living in his existing home. Mr. Galler stated that he would have to think about it. Commissioner Chairman asked what does EAV stand for? Mr. Cooney stated that it stands for equalized assessed value, which is the value of your property, and taxing bodies that would receive the applicable taxes from the value of your property. He further stated the Village's EAV is just shy of $2 billion, and that the proposal will be about 5% of the entire value of all property in Mount Prospect. Mr. Cooney further stated the operating budget is roughly $75 million, and that if the project is approved, there would be surplus value and therefore could reduce taxes owed by everyone living in the Village. Mr. Galler stated there are people living in the city next to data centers that cannot sleep at night, and property values well decrease. He also stated workers at these data centers will not located in south Mount Prospect, but possibly downtown Mount Prospect. He further asked how noise will be mitigated. Chairman Donnelly stated that he is of the thinking that data centers are very quiet. Chairman Donnelly introduced Dr. Tom Thunder, 867 Scottsdale Drive, Pingree Grove, IL. Dr. Thunder stated that he and the Petitioner are fully committed to meeting Village Code, and that he generated the acoustic study/report. Dr. Thunder explained the methodology toward his results, and 19 that the expected noise levels are above what Village Code allows, but that mitigation is then initiated to meet Village Code. Dr. Thunder further stated that attenuation includes hospital grade silencers, insulated metal panel walls, 5' parallel baffle silencers, 2' foot acoustical louvers, and rooftop noise barriers. Dr. Thunder indicated that noise during a total power outage will exceed normal Village Code, but that is not feasible given the allowances, which is 56 dBA during the day and 52 dBA during nighttime. Dr. Thunder indicated code allowances are reasonable and similar to State standards. Commissioner Beattie asked the specific dBA numbers. Dr. Thunder stated they numbers would be a few decibel levels below Village Code. Dr. Thunder further stated the report notes the official numbers, and then explained how the numbers were derived. Chairman Donnelly asked how much money will be donated to the Mount Prospect Park District. Mr. Cooney stated that is still being discussed and will be agreed to prior to final PUD approval. Mr. Galler asked if the RecPlex could offer senior discounts. Chairman Donnelly swore in Dan Allen, 999 McClintock Drive, Burr Ridge, IL. Mr. Allen stated that his organization represents many different trade unions, and that he is in full support of the proposal to create new jobs for union workers, and that all workers will be from the area, including many that live in Mount Prospect. He further explained the demand the Chicagoland area has for data centers, and that this helps local union workers, including newly trained young union workers. Mr. Allen concluded with stating this is a win-win for both the community, developer, and local workforce. Hearing no further comments, Chairman Donnelly closed the hearing. Chairman Donnelly asked for a motion. Commissioner Beattie made a motion seconded by Commissioner Szymczak to approve the following motion: 1. A preliminary plat of subdivision title "Mount Prospect Technology Campus Preliminary Plat of Subdivision"; 2. A Conditional Use for a preliminary planned unit development (PUD) consisting of three (3) data centers, each totaling a gross square footage of five hundred sixty six thousand seven hundred sixty seven (566,767) square feet, three hundred forty four (344) parking stalls, and a Com Ed operated substation, subject to the following conditions of approval: a. Submittal of landscape, irrigation, and photometric plans that comply with Village codes and regulations; b. Development in general conformance with the site plan prepared by Corgan dated November 12, 2021; c. Compliance with all applicable development, fire, building, and other Village Codes and regulations; d. Petitioner shall provide documentation to the Village that the proper IEPA and OSHA permits have been obtained prior to any certificate of occupancy issuance; e. Prior to final PUD and final plat of subdivision approval, Petitioner shall provide the 20 Village a copy of the covenants, conditions, restrictions, and reciprocal easements document; f. All proposed noise, vibration, and particulate matter levels shall meet Village Code requirements; g. Prior to final PUD and final plat of subdivision approval, a donation to the Mount Prospect Park District shall be agreed to for public improvements to park district facilities benefiting the surrounding neighborhoods; h. Petitioner shall provide all off-site and public improvements as required by Village Code; i. The existing access road between ORD1 to the north and the property to the west (1540 W. Algonquin Road) shall be eliminated, and a turn -around area shall be constructed within the 1540 W. Algonquin Road property; j. Petitioner shall provide a complete building code analysis during the permitting process which shall comply with the requirements set forth in the adopted building codes and amendments as adopted by the Village; k. Petitioner shall obtain all necessary permits for other entities including, but not limited to, IDOT, TEPA, Metropolitan Water Reclamation District (MWRD), Cook County, Army Corps of Engineers, and the Illinois Department of Natural Resources (IDNR); I. Petitioner shall comply with local, state, and federal regulations regarding the abatement of asbestos; m. All signs shall be submitted, reviewed, and approved during the permitting process. All signs shall conform to Village Code unless otherwise noted in the PUD request. UPON ROLL CALL AYES: Olsen, Fitzgerald, Beattie, Mizwicki, Szymczak, Donnelly NAYS: None The motion was approved 5-0 with a positive recommendation to the Village Board. Commissioner Beattie made a motion seconded by Commissioner Fitzgerald and the meeting was adjourned at 8:44 PM. Connor Harmon Senior Development Planner 21 December 9, 2021 William J. Cooney, AICP Director of Community Development Village of Mount Prospect 50 S. Emerson Street Mount Prospect, IL 60056 or Via fax: 847/818-5329 or Via email: ib�moutpros ect.or p Dear Mr. Cooney, On December 9, 2021, the Village's Planning & Zoning Commission ("PZC") recommended approval of a preliminary planned unit development for Mount Prospect Technology Campus by a 5-0 vote (the "PUD"). The special use ordinance approving the PUD is scheduled to go before the Village Board of Trustees for the ordinance's first reading December 14, 2021. We are requesting that the Village Board waive the second reading, tentatively scheduled for January 4, 2022, and take final action at its December 14, 2021 meeting. The reason for this request is that CloudHQ is obligated to close on the subject property no later than December 21, 2021; if it does not close by that date, CloudHQ may lose its earnest money and fall out of contract to acquire the property. Before it is obligated to make the substantial investment of closing on the property, CloudHQ would like to determine whether the Village will approve the PUD that is necessary to operate C1oudHQ's proposed data center campus, on which the purchase price for the property is based. I appreciate your assistance in facilitating this request. Should you have any questions, feel free to contact me at 571-447-7255 or by email at fbfburnetl .(uLcloudhq c r n. Sincerely, Brett Burnette CloudHQ 1212 New York Avenue, NW, Suite 100 Washington, DC 20005 22 Z Q N Q U } O O z 2 U W H F U a O K a z O ,° z 0 LLJ Z 0 w U- T— z 0 LLJ LLJ to w W MAFM ce. A o", Jmi Ix Cl) Z 0 Q J LJ H b 0 Z U a. F- UO o 6 w W MA H z W W U M LL O z R 2 r z 2 W G z W w N°�rcpa�� o urmrr Im�� g uux66��unr ",larvaoalr 3 .... - E IIIIhli 26 W U LL O LU F - z LU U Q a G N 0 z 2 W a z W w N°�rcpa�� o urmrr Im�� g uux66��unr ",larvaoalr 3 .... - E IIII li 27 Z O H Q LU J W H Z O LL M Z 2 W in Z W w N°�rcpa�� o urmrr Im�� g uux66��unr ",larvaoalr 3 .... - E IIIIhli 28 C -D m NO C -D 30 Co z C o z z I Q J ty W 0 Z Q J n J_ C o z z CIVM:J NVA3NNII Co z C o z z Co z I LU a W - W U' .......... ............ 0 0 M N O m � � LU 3 2 � z 3 I LU 7 Q z � s E =G ° E° as O °J l0 - N £ S o 2 6 d W W - W W A ,E z e Z y i E a r o N o Z g t E 3 0 0 3 0 Q f o _ °e w eS s ZLU zi a c o E o �� ° - �z cros_ o z V 'E LLI Q// Z u j y it J Q w° za sz WIN a v o �z z � m � anJw� h � ow =z NLL xd wr � J U J n U) O If a - Z O LL O J O Q J J_ N D IL a v O J O z �.i W V n W c a d o.... ll F Z O 2 I� o%/ii;;;i ,,,/iii ..�„w iw,..m�nededW vndM&mh, N o wq, LU LLQ FaU) T Zw O~ U) o a O cr N z o2E LU w z (n J 0 z O V vJ L w Lu N z O U)r^ VJ m CO w I rr Q Z_ J ry w n J O w I O w w Z O L ILL O !w V Q J J_ N D IL 'a V V O J O Z r' v w H � cr LU JL o ...... ll is ILF Z O; 2N w 0 cc CL 2 0 � � m m � � 2 « a � 2 LU 2 0 cc « z LU \ z 0 3 2 > / m ƒ 2 2 \ z < Z_ 2 \ ± u 2: LU LU.§- : :� : - �_- � w 0 cc CL 2 0 � � m m � � 2 « a � 2 LU 2 0 cc « z LU \ z 0 3 2 > / m ƒ 2 2 \ z < Z_ 2 \ ± u 2: ♦V E E E E E _ E E _ — _ E E LU J E 0m - = p W E 2 E E a SE UE S y w� wa Z N N O N Q J a w ZOn'" O U s- dO OY t — p XS - J W U cc a a z O Q fn m y Z Q J a H z W 2 W 0 cc a J z W H w CL O cr CL z 0 a H U) m Z) y 0 z U Q w LU LU H y LU F -- Cl) y d LU M 0 z 2 00 �Ir aLL >� LL, w J W > _ J U w n UD O rTw z O H O III O Q J J_ y D IL a U O J O Z 2 U W � cr U� W JL y ..... O GC Z O; 2.; EL s s Z W V p w Z cc3 w w N Z y U) > o r m LU i a a W s w w m> > a z N ~ W J a O y m C >. ! a W Z Q 2 ri ri m >> (A p w - w r z o a o N W a Z� OyQ02Q d N f Q LL O i F� a o fQ/f 3 N N J p 0 0 Z Z z oy = o w J21 p W W° a Z i FOOWc M WrOQQQJ22 Z (A (A a Q d d a a c z c& o as 9 N k X= W U F F a M () J J J a a a J Z� a a a N a >> O Q v ~~ � r W LU LU w a F i3 o � z 3�� �� i w a " zcc A Z Z Z N y J J J z f F3o oa a �} w o F o ? J N N fA W J Z J J J W >OCOHHH¢Www a a a W LU aH H H S 2 W W N 9 zo o U3 N ow ov,LL o5 o= x LL _ w H H W W W O a o>> 7 a <A U) a p a >> W F F F o, �� lo. . ow. ZW O O r N W 0 r O r N O r N O r N O r W a J Q Q Q u s 10 W o U U U U U L)i (0) 0 (Qi La in 5 L)i V U U U Q U a r a r N vi Wv=i a — r O O r I/� �/�Z Z O a r J F a w� W N o W <r z > a Oza a� o W o a p3oo c> CMJ W =j v e� W awo Jww Z ow, s �N¢ 6 �3 cl ¢8g Wa g w rv a = gq _ wo Z C.4 o _ �. o 2 =ao w,mm d wo = `�� o Nyo w ¢ W 7 Y) S�® �� V ¢ozl p ¢i2N �fp Q ILIU r/ $ Z co) N =m uooJ d� ui 6Zr�w w 16 Q c o_IM O M. 1� 2w Pq W O a e�+ ( ! w o o Z N wmw wy � (aj aN r��Z 003 Z W Q3N=w wNwa �o.w W Joo o Z O J a W =$v weea W Sao O. Z �= i,, o � IL o = � Q1 "L.. mzo a HO ZO 0 J oa O2Ld 0 0 N Z W - T a = o u a YU - � QQ J _ W e oo oIs u p I i�i OC -_ W�o d fes$ ��• a zS2 - p - 3ottoow�¢ --- 0 - -- Yo oz3zr�<¢oi N - --66 --"oo p>ppo - - �3 LL 3 a w_ m y U t � �`Ipll 3 an o f:.€ L�€;e `€€ n w , w � o € F AN less!€ -z �5 x m + v o r L k t. E!9 p_2+. o- e m i � ryy��p4 is,H z 4 N e I Z oaN 4 � 00� q amm z Z J w^9a FQ �a Zw w a Z 00- aF CO) = _ 1 mzo € �o w z� Q i, IIf JIIIJ �1[111I II _€_ ,.n.. �' 2 L y' € O 3 x 'I 9i UP. i dal d: JJ M M M i€. d, W I.—Z - - � Com' � • - _ F N z � a ®o •�l oao ,®m.eo+w•©®c®xrb��®o®® .�®oa -Y_® o N ... . . . . . ,. .,.. . .,. .. .......... C4 4 M� Lu ... ol '0" 2- tF . . . . g >.LU a 9 S, 's LU Nd W,, G) Q9 (a) 2 eee oee e (De eeeeeeeeeeeeeeeeeeeeeee Z � m 1- - - - - - - - - - - - 2 m 2 d m n n n 2 88 8808 eeoe e 80 0 e eeee ZO . . . . . . . . . . . . . . . . . . . . . . . . I I I I I 33 3 EE EE EF EE E E E E E E E - - E E E E E E E E E E . . . iii i iiE E E 8 E E - - - - - - - - - - - - . . . . . I I . 1 2 b 6 LU LLI 2 2 LIJ . . . . . . . . . . . . -so E EE F, uj 0 LLI 00 , > 0 0 ZO x () LU W GL LL, �- , 'a €-----m - - - - - - - as - - - - - - - -a - - - - -a ------ - - Lu �- -C 0 0 0 w Ix IL 05D moo Z= z 2 RR� 4 4 22a P.. 4— a 0 Z, 0.4 0 Ld m Em E E E MEE E� E E �E E w EE E E E - - - - - - - - - E E I E E 'o 'o 6' 2 2 2 - - - - --- - -- (ED €-- - ma - - - - ---ma--- - - - - - - - - - - - ---a - - - - - - - - -- - m--m---m---a - - - - - - --aa o 2 2 2 E E I E 1, t°r1 E T I I 61 F I E S - - - - - - - - - a -------a --------- -- - - - - - - --. . . . . . -a . . . . g Boom;_ - - - - - - - - - - - - - - - . .. . .. . .. . - 2 A 3 a W 4 4 ,ARA Rom T I E R m TR egeeeeeeeee e W a C9 60 N aooyW a a O ® a o W 2 .W 22 W Q WdFWFW` F �+ W o� 3 O UWJtiJW 0 a �I W 2 Lu y h 3 4 h O Y 000000 o `l " I a t 3 y` b, � e � ❑ Y \ VyA � d a 4 W__ � 9MN 7064!YWrMm i F W ❑ � W i ` S jj Sit s m I' ® X19 eo ❑ br 0 �' �= ❑ nllnilnllnli��� ¢ w•ew i/ 14 e a w �— "w Ix �F P " ii y R e w , �9 1 � 4,� 3 e n � 0. mzo LLI 0-4 s � � s � e I M I F ILV tt a N z o H m i I a ' a L M M M I Ip I ¢ D3 o 11 II III IIF �•� � ��• �h .._ — Z'L a9.o _ O h � Y y 2 m 4T HC Q U e �I I IW O� 2 O O O O(9) O©©(Z) S S© ® S S O R w ry °WC2i MION O_ Y ¢ �YlfitSNONl 03ll4V/] milli ]dIULS/JONI W Ci UU �� R 1 I a e We W Z zWW �i O02o:z �223 `vro: U�iY�2 30 m� � 2 y = oo888$a WWWWW °3 W, yz wool °w ° Q� m Qu all i :I ; v mz y a ,zH su '.'. 22222 � 22228 mk W WmJ in; CCCC� �n �n I k U W U iJ6"xs m ¢o. " I SrS TOM m ^ h¢ hhh N°v pp SWO ���,11Wy R d hadY m2�24 g m2 old ^Y �dW � too iPi�442 k I �� W®cn g2p ole�2O � jC�ti ,WI 2 �cmie mm U rv°j C5 Uw o gm ¢�2°oWw R W Q SOW 2 �2yy4 jy SU .,•n 2�n y 1 Wa oS 4 22h ¢¢a /r I Ip I ¢ D3 o 11 II III IIF �•� � ��• �h .._ — Z'L a9.o _ O h � Y y 2 w 4T HC Q e �I I IW O O O O(9) O©©(Z) S S© ® S S O w ry ,08'444 M.4Z,bb.LON O_ �6 �6 0 0 �YlfitSNONl 03ll4V/] ]dIULS/JONI I Ip I ¢ D3 o 11 II III IIF �•� � ��• �h .._ — Z'L a9.o _ O h (vL) szzooL dibraw uamoimmwlwo�u � Y y 2 w 4T HC U U ¢ Y ti S o 2 O a e �I I IW O O O O(9) O©©(Z) S S© ® S S O w ry ,08'444 M.4Z,bb.LON O_ �6 �6 0 0 �YlfitSNONl 03ll4V/] �\ UU �� R 1 I Cyi LU W4i2 U ¢ CS C�i3 �U Z zWW �i O02o:z �223 `vro: U�iY�2 30 m� � 2 °j¢ ! Into 10141 � W CJi �4iI � LCJi1 µI Z � � O 2 2 W °w ° Q� m Qu all i :I ; v mz y a ,zH su '.'. o V iJ6"xs wu m 6 wUS a�"�e WS'N t 3 d J Uti w GIN aU�l�2¢ yW�,I ,. LU w 2 s ',. aIa �eie�snom oat/r✓n a C� a w w m x z a o ao mbl m., m., m.. z /r 8 d � (vL) szzooL dibraw uamoimmwlwo�u W z J 04d`o � 4T HC e �I I IW ,08'444 M.4Z,bb.LON �N� �YlfitSNONl 03ll4V/] �\ 1 I '"'�� °j¢ °w ° Q� m Qu all i :I ; v mz y a ,zH su '.'. o V iJ6"xs wu 6 wUS a�"�e WS'N t GIN aU�l�2¢ yW�,I Z Mill L'-L��J a 26UOS¢�i �Y 2 s ',. 1 1 �eie�snom oat/r✓n a C� a �I /r W z J 04d`o T to w Ci �N �o a o_ .... , ,, I ... L 0 h J I w W wnw rP wmma�can Lu u � � 1 u 1101 La Z6 -Mo u it it N oo3 IM YI II Q ooh LLI O �I �� �✓"`/ p Sao Z U l 4 � Z V I O I /� V IL O� ¢.o mzO �Of Z ca U o O ui V M � r o I a I1 Im X I 'JNlJ b'1 S �uli� Y IL I� a i i ,m sy ew a y. NO/lJn&ZSNO ✓ ,w o o Z.I O t' w � p ii Z � I� ✓�. I q Il - b f U f f W � F f, 6 r ✓r� / � N �I 1 � 6bR V w`oo 3 ° E° -mEE EO c Z ¢ O �_❑ _ SE a'Em ° m w E E Lu YES° me W €u m59 ^g �w m' $ �' Y E-89 .RWO c`o Eo - Q 2 3 c Sg t o 'B B b B b .05 ° oB _am woo «a _ W p W W �� N .lit E _ -13 EYm _ w ti -u� B B$oY D E egm o$ o Y 8 m 2 g m o 0 oso$ m 8 mso ¢ 3 a uaog _ °fr ago L$o p 0000000 o mm os9a - ..aE� io cE �o uv,ESc Yn� m-paC _< � „ < � N V � Yo8c bE m' BE mS' "Y' ?P8 3 YO� 2�Em m9 g W 3 w a m�2_9b2�e a - �`°an ra.ho - a.�°- W w w v z o i m i soa o E'c @8� N`o e�°5;° 5b o a °8 --e rE J Fn Fn Fn rc rc � i Bi z 3 I €_ s, °�<��a2"E3 €<E3 �� pp w Y g`Y a@m _- -9E Es z w w w a d d �G, �G, g >> c m m a °ac` mS mE ;S mRC m �° a`�8m E - =E •J•• �BnS a a ° d ® ■ d ®m o "+} 3 J T~ I ® O❑ B O®® b e -P � 4 a Lu a a - _— - - LL, �y jail r V �aLu LU 0 01 w Ix ill I O wzz 1 l d o» 0-4 I I z , � ill � I •, i u, �� � Ill _ w �I w _ , Wm _ --- - , Iy I _9 - E Q V V 6 V urn- E a agw Y > o0 wE 3 ° EU -mEE EO E `° a > 2 3 W96 m9Eo `° o frmg a` _ t m .`°� 9 '-°fro P „4 P - ° W ESo-E i € aU3o z- _ s Z 3 W Q In 3 m$o E 8 = a = EBBS ,Qm° _°�Et Q_ - _ Q S o LU mB E m fr a b ce3 EaEm - W OC i mot `o m �o _-4, m -v� a a " 8om`o c° E :,�Eo ° o W W U J Q ti, V *E m 8 ms' ff g z -M - _ wfr $oCa `° '�$ p IS 2 8e° °�°` mohm E v ,p °';o$ =`mfr c wE =2im 2 Ecm 'mfrEc Em_[ Toa Bfr=E bfr m vada ods - vEa _ aa= @ oam 2 - E BE �- oro� vYS^- _ ° ..E B W 90 iX 3 m mg gR g = c$9=,g 9bg m =a8 _ �akm m9 C7 > m Q o = a uS V o a °a yE j F F F It z a°ac` mS mE ;S m.'pC Q w w w a a a < < o m M 1 E - =EJ 4BnS a a1 _ - - - a T ® • ■ e ® m 0 ! } -r (— 3 F y ® O❑ B 0®® b e a II_16 w L ... • a t _ 'JI w —- ----- m /7/� N o F I 0 Lu Z I oo Oo- m a �o0 7 g lhJ Wena. a Q wZz d CIO 7 111 0 ras�o ! n { p G o o A - 101 �m II YI III a -- �T I {��� I � afr 15Eg e Y i SS e i ry � I� Jh III f W W S N ~ oy mcc �. F pL a ti f16 N 3 ooa 003 O o J E =NU Q F- ,* c0 CL VOA Lu Ix a. F o>; J a=0 F 02 F0 > >a 0 2 L 0 0 N II i fiI , / //�1// " oI LI �C:3 —___^--- ry \` 11 RA Yp Y b OW F Hat, b� gg NIN V.�I�``vv''nn��� ggp��p'�iQ4QQ4Q$ I Jo 2 w = v o __ a m• W � e m �e'� ��_ oN v� aEo yNj o3 m < s5 8a ffi _' mom lotLLI e �� n 8 d d y o F Ko a€ -_ a e o c $ v"` w oo � y tL�z• £h 2QN2 EJc°'u � ` ° o E�; So ae m n m e�cm — _`O - Y ^° S - F eEc E o e e O E) 8 OO OO OO quill € frB:.o o E m°<aEa Em Ti$u = 0 14 ^ o m �=`on W4mo „E - ilf£ mC- m @aO= Q M; W ffiy i 1 o- @o $ HayMc=M om - $Ea h 'e` m = h5 =m� niiiQE� maaw n =a u _'3 E ___-�usmmmamEm a 8fr a g°s Q;o mQ�naa2'un� &ar S� 8 8 �6; rc'J y rcEu v" R J2V __ m a u v m N _ � o oI LI �C:3 —___^--- 0 888yC,C8 I m $ ,I / ry \` 11 RA Yp Y b OW F Hat, b� gg NIN V.�I�``vv''nn��� ggp��p'�iQ4QQ4Q$ I Jo try -q / 0 888yC,C8 I m $ ,I / ry 11 RA Yp Y b OW F Hat, ggp��p'�iQ4QQ4Q$ 01. a'£ r M rte. I i Un A MY Nit RA 4pv¢ %Ua¢ll M¢ ao Oona �O�N �ONry I- W W J �y J a a� OC vas' YW yio o OJO J Op— e =NU Q F°tia cN d 8.0 0 ,z1z C a=0, a FO � oa �y o �w o N 04d`o LO w O LLI 21 3JYJ 8N16//09 LU JI LU ---- 3J-vj- MA IMI, I hall HIM oNN HIM 11 fliff �p' 11 11 HIM mvj IN N I LLI W W Z 0LLI o o, �VJ 0NI07109 0 � o 0 NNW WLUz rA s U) xry Lu LU a LLI aII"a HIM U) 0 Hill LL, 0 R: Lu m 'm 3 lz on u) . moo h loo' 11 &Z, 0 Z n 0.4 Ld o Iii HIM Mao-2 MVd ON�M Il 6--dn tj 7 W7 N � L y w � y m W O Z o W % p 2 2 W Y m 2 a g m� W m m 2 ae 3 o_ ¢o v^ ;xroa -- c> o I I 3JV�JNIOI/�6 %I 3vn umdoad I � ZO INN,, I I S ff glitss I S c� ?'33as lz 11 1€€< mall, a � iii! W E ISS Illaaaaaaaaaaaa SS� oi£�3 ISS l o000000000000z �'JJ% Q „SII/i < I I SSSSSSSSSSSSSSSSSSSSSSSSSSS% F w jil ,fir,:^. I SSSSSSSSSSSSSSSSSSSSSSSSSSS% W ir N / 1 I U I I SSSSSSSSSSSSSSSS`,""",,,, o00000000oo?';S iiiiii"" p i F a I 2 I Z V a y O O 0) L a \ ~ V w ISSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSS illlllllll F V Z O O o' JO \ W rn 1 o„ „ W y o =ro I i Ioattttttttttotois V waa eve sromme I l llllllllllllllllllllllllllla W o w llllllllllllllllllliiiiiso; W 0a aIx O5m Su <' a O I I I I I I xna — � I I � I I I 1 1 1 moa I I _ €� �a Is 1 I / I " � o I 1 I 1 I I tf N / W a _ N • L7 6 - t r R'C'51 Q 7 21 0 IL C� Iq z 0 dgo E, z IL W aid LL 21 ww C) �3 0o zT m < F3 LU LU 2 0 U) 0 LLI Z o 01 'w lt oc LU IL ow a—A O w Ix 505 ; IL 10 BIG OIS zm� 13EHS 0.4 0 0 0 0 ------------------ 0 ix CZ ......... . -------------- W2 L........... I ....... .............. L I El E—I ,y o i oc, ri IN u yy C gg y 4 z5 6 1I® �c S t� O �I x 4 S j � �/ xi ✓ # � $� IL m - — - — oug w �oFina w o N � Q n O N w .��.. I � w s w w'2< a o w rz ff s s m °, � r.. — u >t ' 3 2 -------- .... °o wa . J 2 �q a TO - ...................... s s Rater eta a g xa t(• a, x.. a as #..x 7 r ' a LU i r t gg E y y W s a F g z x§335a3 4� y ......................_ Y y JOOJ E v w of a. 61LLI U C a _ arc y = Q e r +a m 0 0 111 2 p o V' J � Y �d g C � ee4 v .... O dl s H JF9f IYY O - , ° s §� �� � � � � �g �i a fig& I°i�(�!g!~� 9 � ass $ q 5 3 t �9 E! �( s w u... !� 1 �."� ,. : � � � ! :e !. I. •ifY @ fru.. �'EE.5.. a `-Y .a�oraarruv`:� V all e $ n u I .�; all 31 'R | f ; � \ \ }\ (\ |§| � r' .._ :........ § + z ; .. . . .° § § | m Lu §Lu §� U) § s ;mak Soy > 22/ o §`° L`K G§ 2 z § IL z w 2G= o � �§ LL, §- � d | § e \§§ e � �ƒ) p e / e § »m o j� 2 , d �2 tet% � /; 00 0 tu �A. s g o Wh- E5 WE vq� . . . . . Hill X 000 A -e 11 E ZO 2 M g -HP V4 z t el/ lao —§VO()S JAMWV3JUM 39V77M 01 .67TLt M..LO.gt.( Y4) qz — — — — — — 7 matIII 2 C, & 0 .... ......... oo -- --- -- - -- 4 w---------- -- — --------------- --- 9— / maw i.. CO) JABSW.IM -WV7'M 01 t------------------ -- -------------- zo �o 3 ----------- — --- LL o .0 o z Foy 0 om z LU 0. WIL z 005 E m 0 o R Sr o z^ �/ l Z Woo -g" M.6Z.2VAON 0 0 20 LU <t0 z e pgaQN 0 3 V) 0 oxo Z CY �UO j - - ------- -- - P Z 0 In 1: 0 T-2 b u Lu RE CL < ot: < z s LLJ 0 —797 2g 9 3.6Z.£4JOS :3 3. C, 2 t 3,,Vz^ws CLLC W Fe€n 3w I 0 2 mww"i MVTM of onwmo 'N' 2 af a - � r r oo XF 'H Rw- 0 � o _ H - > � m Z a J a w O 0 LL Z O U LUJ Q v a F- D Ili co 000 WO 0175 16 DroO"'i 4611W to/r, els ` El�ctrrc P4vv�r Package Performance Performance .. Frequency 60 Hz 60 Hz 60 Hz 60 Hz Gen set power rating with fan 3000 eKW 3000 eKW 2725 ekW 2500 eKW Gen set power rating with fan @ 0.8 power factor 3750 kVA 3750 kVA 3406 kVA 3125 kVA Emissions EPA ESE (Tier 2) EPA ESE (Tier 2) EPA ESE (Tier 2) EPA ESE (Tier 2) Performance number Fuel Consumption 100% load with fan - L/hr (gal/hr) DM8448-10 810.7 (214.2) DM9226-03 807.1 (213.2) DM8449-06 723.8 (191.2) DM8450-04 662.5 (175.0) 75% load with fan - L/hr (gal/hr) 625.8 (165.3) 616.1 (162.8) 571.0 (150.9) 526.1 (139.0) 50% load with fan - L/hr (gal/hr) 493.6 (130.4) 489.0 (129.2) 462.0 (122.0) 435.0 (114.9) 25% load with fan - L/hr (gal/hr) Cooling Radiator air flow restriction (system) - kPa (in. water) 305.0 0.12 (80.6) (0.48) 313.6 0.12 (82.9) (0.48) 295.1 0.12 (78.0) (0.48) 278.2 0.12 (73.5) (0.48) Radiator air flow - m3/min (cfm) 2933 (103578) 2933 (103578) 2933 (103578) 2933 (103578) Engine coolant capacity - L (gal) 303.5 (80.2) 303.5 (80.2) 303.5 (80.2) 303.5 (80.2) Radiator coolant capacity - L (gal) 632 (166) 632 (166) 632 (166) 632 (166) Total coolant capacity - L (gal) Inlet Air 935.5 (246.2) 935.5 (246.2) 935.5 (246.2) 935.5 (246.2) Combustion air inlet flow rate - m3/min (cfm) Exhaust System Exhaust stack gas temperature - °C (°F) 276.7 477.7 (9772.2) (891.9) 264.9 479.4 (9354.6) (894.9) 249.0 460.9 (8790.7) (861.5) 233.4 444.1 (8241.9) (831.4) Exhaust gas flow rate - m'/min (cfm) 725.6 (25620.0) 695.6 (24561.2) 634.0 (22388.6) 579.4 (20460.1) Exhaust system backpressure (maximum allowable) - kPa (in. water) Heat Rejection Heat rejection to jacket water - kW (Btu/min) 6.7 1379 (27.0) (78436) 6.7 1373 (27.0) (78059) 6.7 1248 (27.0) (70951) 6.7 1161 (27.0) (66018) Heat rejection to exhaust (total) - kW (Btu/min) 3149 (179063) 3128 (177889) 2726 (155037) 2494 (141849) Heat rejection to aftercooler- kW (Btu/min) 496 (28224) 492 (27992) 391 (22254) 349 (19848) Heat rejection to atmosphere from engine - kW (Btu/min) 147 (8336) 182 (10340) 170 (9645) 165 (9390) Heat rejection from alternator- kW (Btu/min) Emissions (Nominal) 112 (6369) 112 (6369) 99 (5619) 112 (6386) NOx mg/N m' (g/hp-h) 3113.9 (6.07) 3103.2 (6.07) 3313.2 (6.33) 3260.4 (6.12) CO mg/Nm3 (g/hp-h) 325.6 (0.73) 149.2 (0.34) 184.9 (0.41) 222.9 (0.48) HC mg/Nm3 (g/hp-h) 40.7 (0.11) 15.7 (0.04) 16.4 (0.04) 16.8 (0.04) PM mg/Nm3 (g/hp-h) (PotentialEmissions 13.0 (0.03) 10.0 (0.03) 15.1 (0.04) 15.2 (0.04) NOx mg/Nm3 (g/hp-h) 3736.7 (7.28) 3723.8 (7.29) 3975.8 (7.59) 3912.5 (7.34) CO mg/Nm3 (g/hp-h) 586.2 (1.31) 268.6 (0.60) 332.8 (0.73) 401.1 (0.87) HC mg/Nm3 (g/hp-h) 54.2 (0.15) 20.9 (0.06) 21.8 (0.06) 22.3 (0.06) PM mg/Nm3 (g/hp-h) 18.2 (0.05) 14.0 (0.04) 21.1 (0.05) 21.3 (0.05) LEHE1224-00 Page B4e135 of 158 69 9M OHcinmoti CP 0 u3 Gi .............. ........ - ----------------------------- age WW nqm. ............... ----------------- ------ -------- ........... IMMIMMM ..... M'9�29 '. J1 J.J, J"J.JJJ.JJJ .... ........ ....... ......... M--� ui C) z W Irl W U - w re U- LLJ >- uj In E < E u) > of g 0 w I w -OHIcinmo 9M > o o oy QQ QT e- t t- — - — -- -- - - --- - - -- - - - - -- ------ sI - - - - — - - - - - - - - - --- TF -70 II it - - - - - - - - - - �--- I of - - — - — - — - - — - - — - — - — - — - — - — - — - — - ........... W4 L---- 9 71L mvp�o - -- ----- - - ----- - -- — - — - — — - — - — - — - - — -- W� DOW jo, -ji IR ----------- ----------- 1, 111 III ui ui ui A- LL ui (E- LL L* PP vs (H)-- (E,-- G— G— o— (D-- z 0 uj c) T-- z w Irl w U - w re ------ ----------- F r -4L-- -------- r j a z - ----------- -i--- L E! N - --- — - — - — I — - — - J IP 60 - — - — - - - — - — -- -- — - — - IN -,I 31-I 11h - -- --- ---- - P-1 04 my IV =-- --- ----- - -- ----- -------- ------ J-41 muz - - - - - - - - --- G- CP a> LU CD < 9M OH(inmo U) LL, [if > oy C I I I I I I I I I I I< 0 "n- (H)-- (E,-- G— G— o— (D-- z 0 uj c) T-- z w Irl w U - w re ------ ----------- F r -4L-- -------- r j a z - ----------- -i--- L E! N - --- — - — - — I — - — - J IP 60 - — - — - - - — - — -- -- — - — - IN -,I 31-I 11h - -- --- ---- - P-1 04 my IV =-- --- ----- - -- ----- -------- ------ J-41 muz - - - - - - - - --- G- Z gra �' e O _ rY - Q S 6 w LL❑ a F M R W m Q U` W m ' 7 9M _ O ci mo LLaO � y o a � u d � wIi z s ¢q l —4=_ _ _ _ I� _ _ lel E _ _ ------ I .. ° II i i it � _ _ _ _–_r _ _ i it i � _ _ _ _ I I I� I I l LE IL - - -I - I - - - - - _r_ _ __ _ _ _ �- - - - - - --- - - - - - - - - I I I — — - — — __ -- — __ — — — I — — — �_ — _r_ — — --_I — — Ili — — _�_ — _�_ — —�a LL — — — — — — { _ — — — — — — --- — — l — — — — — — — — — — — — — — — — — r — I l _ I I — — — — II I I I +— — _-_ — _ — --_� — — I II — — __ — —+— — _ I i i — — — _— — — y — — — — — — — — — — I V I � ui V �- C) I ° �_ - _�_ - - --_I _ _ _ _ _�_ _ _�_ _ _ _ W W Wui I i x AESTHETIC APPEAL. UNPARALLELED PROTECTION. Traditional security fences of chain link or wire mesh are no longer enough to meet todays increased security demands. Ameristar's Impasse II security fence offers the resistive strength of heavy-duty steel pales secured vertically to a framework of specially formed rails and I-beam posts. The stylish design of the Impasse II, combined with its strength and security, provides a successful first line of defense. Primary applications for Impasse II ornamental steel fence systems include: Military Sites � Government Facilities Petroleum & Chemical Facilities Power Plants & Substations Airports Data Centers Ports of Entry Water Treatment & Storage TRIDENT'" The I passe Trident pale rises above the topmost rail and terminates with a menacing triple pointed splayed spear tip. The intimidating look of the Trident corrugated pale is a visual deterrentto any who would dare to intrude. u� 3 -RAIL PANELS 1 6', 7', 8', 9' & 10' HEIGHTS 2 -RAIL PANELS 16', 7' & 8' HEIGHTS STRONGHOLD'" The blunt, slightly rounded tip of the Stronghold offers strength when necessary, while providing safety and security to the general public. The Stronghold features the same structural configurations of its high -security counterparts. 3 -RAIL PANELS 1 6', 7', 8', 9' & 10' HEIGHTS 2 -RAIL PANELS 16', 7'& 8' HEIGHTS .............................. ANTI -SCALE OPTION °ms � 81/4" GAUNTLET'" Gauntlet is designed with high -tensile steel corrugated pales that rise above the topmost rail with an outward curve and terminate with a triple -pointed splayed spear tip. The outward curved pales discourage attempts togain access by would be intruders. 3 -RAIL PANELS 161, 71, 81, 9' & 10' HEIGHTS 2 -RAIL PANELS 6', 7' & 8' HEIGHTS The Impasse II Anti -Scale fence system has decreased pale spacing, which helps deter the assailant from climbing, and increases the delay time when trying to cut or pry through the fence. ....................... COLOR OPTIONS .m.o so BLACK BRONZE SAND WHITE Custom colors also available �piaiaiaiao� �ia00000 1� Ilup�� %% 0 979TI M, Impasse II is protected by the unique PermaCoat process. Our PRE -GALVANIZED STEEL BASE MATERIAL is subjected to an 11 -STAGE PROCESS to cleanse & prepare the steel for a DUAL TOP -COAT FINISH. PermaCoat's corrosion resistant abilities far surpass those of painted surfaces and have a "no -mar" polyester powder top coat. This dual coating not only provides RESISTANCE FROM WEATHERING but also reduces scratch & burnishing marks typically encountered during shipping. ALKALINE WASH Cleans metal for proper adhesion of zinc phosphate 0!, ly, I EPDXY POWDER COAT Epoxy powder is electrostatically applied 0, P, PHOSPHATE RINSE Corrosion resistant layer that assists in bonding powder coating POLYESTER POWDER TGIC powder is electro -statically applied 4D,,� I - CLEAR WATER RINSE A bit of clean H2O to prep for the next phase 001, FINISH CURING OVEN Seals finish for years of maintenance free use CLEAR WATER RINSE Final wash inH2Otoremove any excess debris mparticles ONCE COMPLETED, THESE 7 -STAGES WILL HAVE REMOVED EVERYTHING FROM THE SURFACE OF THE STEEL THAT MIGHT INHIBIT THE FINISH FROM PROPERLY ADHERING DURING THE NEXT 4'0AGES 0FTHE COATING PROCESS. Corrosion occurs more easily without the proper preparation & protection, which is why Ameristar has put our fence products t0the test based ODASTM 8ll7standards. The results speak for themselves. 3,500 HOURS ('HOURS) (HOURS HOURS PANTED S/Ifl PRIMED &PAINTED STEEL SINGLE COAT PROCESS SINGLE COAT PROCESS Iron Phosphate + Zinc Phosphate + Polyester Powder Coat Polyester Powder Coat PERMACOA7PRDCESS Zinc Phosphate + Epoxy Powder Coat + Polyester Powder Coat Impasse II panels and posts are manufactured using HIGH -TENSILE PRE -GALVANIZED G-90 STEEL. Each component has been ROLL -FORMED into a unique profile that yields significant strength properties. Impasse II's distinct design enables the fence to TRAVERSE AGGRESSIVE CHANGES IN GRADE IN ORDER TO MAINTAIN SECURITY along any perimeter. Each connection point of the Impasse II system is secured with TAMPER -PROOF FASTENERS providing the HIGHEST LEVEL OF SECURITY & VERSATILITY. POST CAP Cast aluminum cap adds beauty and provides closure FASTENER Security fastener prevents tampering or removal by typical tools e�!, 'k, I I -BEAM POST Specifically formed I-beam; pre -punched for rail attachment with pass through integrated design features 2 STEEL PALES Specifically formed high strength corrugated architectural shape resists prying or bending; bolt holes are recessed to prevent bolt head from chiseling HIGH STRENGTH RAIL Specifically formed for strength through architectural Impasse 11 Gauntlet shown shape; lower lip contoured to conceal & carry security elements such as anti -ram cabling, IDS, etc. PRI VA C Y SCREENING OPTION A security fence should cover multiple aspects of perimeter security, which is why Ameristar created the steel privacy screening option for its Impasse high security fence system. Secured by each adjacent pale, the overlapping design achieves the maximum level of opacity for visual screening. RAKEABLE VS STAIR—STEP °®a0 Biasability at a minimum of 25% that requires no additional assembly. This unique feature eliminates unsightly stair -stepping panels. Fully rakeable panels DESIGN INTEGRATION The Impasse II framework is a raceway for wiring, conduits & security cabling required around the perimeter of a project. This integrated design eliminates the need for costly trenching & boring becoming a value added solution for perimeter security upgrades. (inside of rail shown above / view from protected side) When installing these security elements use Impasse /I as a platform: w Communication & Video Cables �w Intrusion Detection /Fiber Optic Cables Access Control Wiring Conduits !�, Anti -Ram Cabling (Stalwart IS) Certified by the US Department of Homeland Security as a method of risk management against acts of terrorism A"0J*VMS Ameristar' Impasse II is backed by over 30 years of excellence in the fencing industry Ameristar is committed to providing products that meet the Buy American Act IM Ameristar products have the opportunity to earn LEED points 0 VA,' I ft ft ti't, 11 Z % a I Stalwart IS unites the strongest security fence available with the most widely used anti -ram perimeter barrier. The appearance of Stalwart IS is a great visual deterrent that delivers strength and fortitude for keeping any assailant from easily breaching the perimeter. L 50 M40 M30 PU6C0JPU50JK12JK81 Stalwart IS offers multiple anti -ram ratings. Each installation can be designed with the most appropriate standoff distance from the asset. ARCHITECTURAL SUPPORT `SOLUTION SPECIALISTS Ameristar's Project Solution Specialists are experienced in every facet of perimeter security design. Our goal is to assist the architectural community in finding the best perimeter & entry solutions for their projects. Ameristar's extensive library of project photos, CAD drawings, architectural specifications & project budget quotes are just a few of the services our team offers to complete your project design. SLIDE GATES SWING GATES Egress &ingress requirements are unique to each application. Managing traffic flow & usage demands are of the utmost importance, which is why Impasse II is manufactured in a variety of gate types built to balance function, security &beauty. AmeristarTransport— &Passport— sliding gates perfectly match the perimeter fence system to create a seamless & stunning design while exuding a commanding presence of security built to unite perimeter and entry. KNOWLEDGE & EXPERIENCE Ameristar was chartered over 30 years ago in response to the demand by consumers &specifiers for specialty fence products. Ameristar offers an aesthetically pleasing product that is both high in quality &afordability. This has been achieved by maximizing high-volume productivity, increasing product design strength, and promoting simplistic installation. ,,, PROVEN CAPABILITY Ameristar's integrated in-house process &extensive raw material inventory results in much improved productivity and availability compared to the competition. By having a vastfinished goods inventory, Ameristar is capable of deliveringfinished products faster than competitors who sublet the majority of their operations. INDUSTRY LEADERSHIP Over the years Ameristar has continually raised the bar across the board in the manufacturing of high quality, innovative fencing products. Our demonstrated commitment to upholding higher values translates into superior products that go far beyond merely meeting minimum industry standards. Ameristar's world headquarters, manufacturing & coilprocessing facilities in Tulsa, Oklahoma, USA. LEGEND 'IV * Ameristar Headquarters • Sales & Service Centers #9718 1 REVISED 06/2020 i ri.tee°° °°�',Ic:t'ive i' 'ierm • Ordering Information pagez • Mounting Details page3 • Optical Distributions page4 • Product Specifications page4 • Energy and Performance Data page4 • Control Options pageg QU IIIdk IIIIII"ac"ts • Lumen packages range from 4,200 - 80,800 (34W - 640W) • Efficacy up to 156 lumens per watt • Options to meet Buy American and other domestic preference requirements 5/16" )MM] NOTES: 1. Visit fitSps:/Lwsxx��deSigsdii�hLuugL,c:uCntlL to confirm qualification. Nat all praduct variations are DLC qualified. 2.IDA Certified for 3000K CCT and warmer only. (,'�jCOOPER Lighting Solutions uo91111N oumou � INmn mo NIwN �����uIIIVII� I I�iN m u `Nll:l,,l,�I @Nuum� raw-, 1Nriri����i -, �'ouuuuma ami ^��knm �Wlllu"' GLEON Galleon Area / Site Luminaire !���Ilil�rodrrcIl Fr�� i�xtt�,ires oo Ilmurucm4�atloa Ncnlliunnllra?Ilp+ Light ARchiteff- III���ui��rN�mr�r����°°lu� CERTIFIED 11101"' C ori"n e:cm,UI?:d S:'ullrv° 4l4 pr^p l it • WaveLinx • Enlighted "'"S500020I:114 111 86 O t:olt r20,I,021rt 4AI Oiirdleiir ii iiini� w SAMPLE NUMBER: GLEON-SA4C-740-U-T4FT-GM GLEON=Galleon SAI=1 Square A=600mA 722=70CRI, 2200K L1=120 -277V T2=Type II [Blank]=Arm for Round or Square Pole AP=Grey BAA- GI-EON=Galleon, SA2=2 Squares B=800mA 727=70CRI, 2700K 1=120V T2R=Type II Roadway EA=Extended Arm' BZ=Bronze by American Act SA3-3 Squares C=1000mA 730=70CRI, 3000K 2-208V T3 -Type III MA= Mast Arm Adapter" BK=Black Compliant" SA4=4 Squares D=1200mA 16 735=70CRI, 3500K 3-240V T3R=Type III Roadway WM=Wall Mount DP=Dark Platinum TAA-GLEON=Galleon, SA5=5 Squares" 740=70CRI, 4000K 4-277V T4FT=Type IV Forward Throw QM=Quick Mount Arm (Standard Length)11 GM=Graphite Metallic Trade Agreements Act SA6=6 Squares 9 q 750=70CRI, 5000K B -480V .a 9=347V 7 T4W=Type IV Wide QML=Quick Mount Arm (Standard Length, Large) 31 WH=White Compliant" SA7=7 Squares' 760=70CRI, 6000K 5NQ=Type V Narrow QMEA=Quick Mount Arm (Extended Length)" RALXX=Custom SA8=8 Squares s 827=80CRI, 2700K 5MQ=Type V Square Medium Calor SA9=9 Squares 6 830=BOCRI, 3000K 5WQ=Type V Square Wide SAi 0 Squares 6 14 10 AMB=Amber, 590nm SL2=Type II w/Spill Control SL3=Type III w/Spill Control SL4=Type IV w/Spill Control SLL=90' Spill Light Eliminator Left SLR=90° Spill Light Eliminator Right RW=Rectangular Wide Type I AFL=Automotive Frontline DIM=External 0-10V Dimming Leads"d' BPC=Button Type Photocontrol OA/RA1016=NEMA Photocontrol Multi -Tap -105-285V F=Single Fuse (120, 277 or 347V Specify Voltage) PR=NEMA 3 -PIN Photocontrol Receptacle OA/RA1027=NEMA Photocontrol - 480V FF=Double Fuse (208, 240 or 480V Specify Voltage) PR7=NEMA 7 -PIN Photocontrol Receptacle" OA/RA1201=NEMA Photocontrol - 347V 20K=Series 20kV UL 1449 Surge Protective Device SPB2=Dimming Occupancy Sensor with Bluetooth Interface, 8'-20' Mounting" OA/RA1013=Photocontrol Shorting Cap 2L=Two Circuits 17.1a SPB4=Dimming Occupancy Sensor with Bluetooth Interface, 21'-40' Mounting 34 OA/RA1014=120V Photocontrol HA=50'C High Ambient MS-1_20=Motion Sensor for ON/OFF Operation, 9'- 20' Mounting Height" MA1252=1 OkV Surge Module Replacement HSS=Installed House Side Shield" MS-L40W=Motion Sensor for ON/OFF Operation, 21'- 40' Mounting Height" MA1036-XX=Single Tenon Adapter for 2-3/8" O.D. Tenon GRSBK=Glare Reducing Shield, Black" MS/X-L20=Bi-Level Motion Sensor, 9'- 20' Mounting Height",23 MA1037-XX=2@180° Tenon Adapter for 2-3/8" O.D. Tenon GRSWH=Glare Reducing Shield, White" MS/X-L40W=Bi-Level Motion Sensor, 21'- 40' Mounting Height14,23 MA1197-XX=3@120° Tenon Adapter for 2-3/8" O.D. Tenon LCF=Light Square Trim Painted to Match Housing 21 MS/DIM-L20=Motion Sensor for Dimming Operation, 9' - 20' Mounting Height 21 MAI 1884X=4@90° Tenon Adapter for 2-3/8" O.D. Tenon MT=Installed Mesh Top MS/DIM-L40W=Motion Sensor for Dimming Operation, 21' -40' Mounting Height 24 MA1189-XX=2@90° Tenon Adapter for 2-3/8" O.D. Tenon TH=Tool-less Door Hardware ZW=WaveLinx Module and 4 -PIN Receptacle MA1190-XX=3@90° Tenon Adapter for 2-3/8" O.D. Tenon CC=Coastal Construction finish ZD=WaveLinx Module with DALI driver and 4 -PIN Receptacle MA1191-XX=2@120° Tenon Adapter for 2-3/8" O.D. Tenon L90=Optics Rotated 90° Left SWPD4XX=WaveLinx Sensor Only, T-15' 1332.33 MA1038-XX=Single Tenon Adapter for 3-1/2" O.D. Tenon R90=Optics Rotated 90° Right SWPD5XX=WaveLinx Sensor Only, 15'-40'13,32,33 MAI D39-XX=2@180° Tenon Adapter for 3-1/2" O.D. Tenon CE=CE Marking 29 WOBXX=WaveLinx Sensor with Bluetooth, T-15' 13.32 MA1192-XX=3@120° Tenon Adapter for 3-1/2" O.D. Tenon AHD145=After Hours Dim, 5 Hours 22WOFXX=WaveLinx Sensor with Bluetooth, 15'-40' 13,32 MA1193-XX=4@90° Tenon Adapter for 3-1/2" O.D. Tenon AHD245=After Hours Dim, 6 Hours 22 LWR-LW=Enlighted Sensor, 8'-16' Mounting Height26 MA1194-XX=2@90° Tenon Adapter for 3-1/2" O.D. Tenon AHD255=After Hours Dim, 7 Hours 22 LWR-LN=Enlighted Sensor, 16`40' Mounting Height26 MA1195-XX=3@90° Tenon Adapter for 3-1/2" O.D. Tenon AHD355=After Hours Dim, 8 Hours 22 DIM10-MS/DIM-L08=Synapse Occupancy Sensor (4 Mounting)19 FSIR-100=Wireless Configuration Tool for Occupancy Sensor 24 DALI=DALI Drivers DIM10-MS/DIM-L20=Synapse Occupancy Sensor (9'-20' Mounting)19 GLEON-MTI=Field Installed Mesh Top for 1-4 Light Squares DIM10-MS/DIM-L40=Synapse Occupancy Sensor (21'-40' Mounting)19 GLEON-MT2=Field Installed Mesh Top for 5-6 Light Squares GLEON-MT3=Field Installed Mesh Top for 7-8 Light Squares GLEON-MT4=Field Installed Mesh Top for 9-10 Light Squares GLEON-QM=Quick Mount Arm Kit 11 GLEON-QMEA=Quick Mount Extended Arm Kit '2 LS/HSS=Field Installed House Side Shield 20,30 LS/GRSBK=Glare Reducing Shield, Black23,30 LS/GRSWH=Glare Reducing Shield, Whit0,30 LS/PFS=Perimeter Shield, Black 11 W0LC-7P-10A=WaveLinx Outdoor Control Module 11,31 SWPD4-XX=Wavelinx Wireless Sensor, 7-15' Mounting Height 1310.32,33 SWPD5-XX=Wavelinx Wireless Sensor, 15-40' Mounting Height 13,19,32•33 NOTES: 1. Customer is responsible for engineering analysis to confirm pole and fixture compatibility for all applications. Refer 18. Not available with Enlighted wireless sensors, to our white paper WP513001 EN for additional support information. 19. Cannot be used with other control options. 2. DesignLighls Consortium" Qualified. Refer to www.designlighls.org Qualified Products List under Family Models 20. Low voltage control lead brought out 18" outside fixture. for details. 21. Not available if any "MS" sensor is selected. Motion sensor has an integral photocell. 3. Coastal Construction finish salt spray tested to over 5,000 -hours per ASTM 8117, with a scribe rating of 9 per 22. Requires the use of BPC photocontrol or the PR7 or PR photocontrol receptacle with photocontrol accessory. See After Hours Dim supplemental ASTM D1654. Not available with TH option. guide for additional information. 4. Not compatible with MS/4,LXX or MS/1-LXX sensors. 23. Not for use with TA FT, T4W or Si optics. See IES files for details. 5. Not compatible with extended quick mount arm (QMEA). 24. The FSIR-100 configuration tool is required to adjust parameters including high and low modes, sensitivity, time delay, cutoff and more. Consult 6. Not compatible with standard quick mount arm (QM) or extended quick mount arm (QMEA). your lighting representative at Cooper Lighting Solutions for more information. 7. Requires the use of an internal step down transformer when combined with sensor options. Not available with 25. Replace X with number of Light Squares operating in low output mode. sensor at 120DmA. Not available in combination with the HA high ambient and sensor options at 1A. 26. Enlighted wireless sensors are factory installed only requiring network components LWP-EM-1, LWP-GW-1 and _WP-PoE8 in appropriate 8. 480V must utilize Wye system only. Per NEC, not for use with ungrounded systems, impedance grounded systems quantities. or corner grounded systems (commonly known as Three Phase Three Wire Delta, Three Phase High Leg Delta and 27. Not available with house side shield (HSS). Three Phase Corner Grounded Delta systems.) 28. Not for use with 5NQ, 5MQ, 5WQ or RW optics. A black trim plate is used when HSS is selected. 9. May be required when two or more luminaires are oriented on a 90° or 120° drilling pattern. Refer to arm mounting 29. CE is not available with the LWR, MS, MS/X, MS/DIM, BPC, PR or PR7 options. Available in 12D -277V only, requirement table. M. One required for each Light Square. 10. Factory installed. 31. Requires PR7. 11. Maximum 8light squares. 32. Replace XX with sensor calor (WH, BZ or BK.) 12. Maximum 6light squares. 33. WAC Gateway required to enable field -configurability: Order', NAC-PoE and VIPOE-120 (10Vto PoE injector) power supply if needed. 13. Requires ZW or ZD receptacle. 34. Smart device with mobile application required to change system defaults. See controls section for details. 14. Narrowband 590nm+/- 5nm for wildlife and observatory use. Choose drive current A; supplied at 5DOmA drive 35. Only product configurations with these designated prefixes are builtto be compliant with the Buy American Act of 1933 (BAA) or Trade Agree - current only. Available with 5WQ, 5MQ, Si SU and Si distributions. Can be used with HSS option. ments Act of 1979 (TAA), respectively. Please refer to p.9 )\!IFS: LI C_PRfFFRFNf FS. website for more information. Components shipped separately 1 . Set of 4 pes. One set required per Light Square. may be separately analyzed under domestic preference requirements. 16. Not available with HA option. 36. For BAA or TAA requirements, Accessories sold separately will be separately analyzed under domestic preference requirements. Consult factory 17. 2L is not available with MS, MS/X or MS/DIM at 347V or 48OV. 2L in SA2 through SA4 requires a larger housing, for further information. normally used for SA5 or SA6. Extended arm option may be required when mounting two or more fixtures per pole at 37. Available for 7-10 squares. 9D° or 120°. Refer to arm mounting requirement table. LumenSafe Integrated Network Security Camera Technology Options (Add as Suffix) L=LumenSafe Technology D -Standard Dome Camera C -Cellular, No SIM H=Hi-Res Dame Camera A=Cellular, AT&T Z=Remote PTZ Camera V=Cellular, Verizon r. „nnai„ny S=Cellular, Sprint „, COOPER Lighting Solutions R=Cellular, Rogers W=Wi-Fi Networking w/ Omni -Directional Antenna E=Ethernet Networking IS50 0201 114 page: 2 87 Octolr i 20, 202f rr 3116UVI Aouiriitiuin�gIII I)e°lu:u��iii1111u Standard Arm (Drilling Pattern) TYPE "N" � 3/4" [19mmI Diameter 2" Hole [51 mm] ;--4-7/8" [22mm] 1-3/4" [44mm] —(2) 9/16" [14mm] Diameter Holes Quick Mount Arm (Includes fixture adapter) QM Quick Mount Arm (Standard) T 3-15/16" [100 mm] „A„ Standard Wall Mount 10-5/32" [256mm] L 6-3/16" J [157mm] Arm Mounting Requirements QM and QMEA Pole Mount k 614'" f nwnk 99 g61.0 J'&'o- IXNo-[ [16,`'1dn"1M166,i 4 o- �MgNd" .. r,� p P2lrpw p•rNl pb�� �i11�66�p P "arum ss p .,. .,. . 1pxmrnu QML Pole Mount QMEA Quick Mount Arm (Extended) ,, .. �p e,.....°pg"rt�rrreu& ,., �&1wty�upvl& Grp ]v4 dw4o-dulB, °k � p p •„easwws p r 6kk w ,lug 1:1,�a�6a�6i Mast Arm Mount 3" O [76mm] 1-13/16" O 3-13/16" I47mm] [97mm] (2) 27/64" [11mm] 21-3/4" 7" 8-1/8" [206mm] L3 -13/64"J Dia. Hole [553mm] [178mm]d [82mm] Ii!liF! StaStandard QM ded Quick Mount 2 Standard Standard QM Extended Quick Mount 3 Standard Standard QM Extended Quick Mount 4 Standard Standard QM Extended Quick Mount 5 Extended Standard QM Extended Quick Mount 6 Extended Standard QM Extended Quick Mount 7 Extended Extended Quick Mount 8 Extended Extended Quick Mount 9 Extended Extended — 10 Extended Extended — Fixture Weights and EPAs 2-7/16" [61 mm] 2 @ 180° Triple' 4 @ 90° fel �i;IrJ;ll I;I„ISI 0. Tri pl e2 �I II;I� �I II;I� ...�✓ �. � �° NOTES: I Round poles are 3 @ 12U. Square poles are 3 & 900.2 Round poles are 3 @ 900. COOPER ss �I��I�u r„�binnr�ai=i�u ii��mq��w�•a Lighting Solutions Octolw i 20, 2021 cw 311 lUVI Asymmetric Area Distributions T2 SL2 T3 SU T4FT T4W SL4 (Type 11) (Type II with Spill Control) (Type III) (Type III with Spill Control) (Type IV Forward Throw) (Type IV Wide) (Type IV with Spill Control) C— FD Asymmetric Roadway Distributions Symmetric Distributions RW T2R T31R 5NQ 5MQ 5WQ (Rectangular Wide Type 1) (Type II Roadway) (Type III Roadway) (TypeV Square Narrow) (TypeV Square Medium) (TypeV Square Wide) L_J L_J ��J AFL (Automotive Frontline) —Specialized Distributions - SILL (90° Spill Light Eliminator Left) couristu°i1sclo111 Extruded aluminum driver enclosure Heavy -wall, die-cast aluminum end caps Die-cast aluminum heat sinks Patent pending interlocking housing and heat sink olfutiiac,s Patented, high -efficiency injection -molded Accu LED Optics technology 16 optical distributions 3 shielding options including HSS, GRS and PFS IDA Certified (3000K CCT and warmer only) 11111arctiii'a:all LED drivers are mounted to removable tray and III',I ijrk)iii°°iiiin iu,:!,Uj�ymc:e1 III)al air Lumen Maintenance (TM -21) SLR Street Side (90° Spill Light Eliminator Right) w � House Side Standard assembly for ease of maintenance Standard with 0-1 OV dimming Standard with Cooper Lighting Solutions proprietary circuit module designed to withstand 1 OkV of transient line surge Suitable for operation in -40°C to 40°C ambient environments. Optional 50°C high ambient (HA) configuration. 1e01i oro1lliing Standard extruded arm includes internal bolt guides and round pole adapter Extended arms (EA and QMEA) may be required in 90° or 120° pole mount configurations, see arm mounting requirements table * Supported by IES TM -21 standards ** Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS -18-18, explaining proper use of IES TM -21 and LM -80. COOPER Lighting Solutions Rotated Optics Street """^•, Street Side Side HouseHouse •�.*,.. Side -^� Side°^....r Optics Rotated Left @ 90° [L901 Optics Rotated Right @ 900 [R901 Mast arm (MA) factory installed Wall mount (WM) option available Quick mount arm (QM and QMEA) includes pole adapter and factory installed fixture mount for fast installation to square or round poles Super housing durable TGIC polyester powder coat paint, 2.5 mil nominal thickness Heat sink is powder coated black RAL and custom color matches available Coastal Construction (CC) option available Y4^°a ll" I'a ird 11':V • Five year warranty IS50 020rla l main ,f 89 Octol1 i 20,202f ct 311 PV1 Nominal Power Lumens (1.2A) ®'" 11 u .ti ""=�""'tlllllllllllllllllllllllllllllllllllllllllllll Nominal Power (Watts) 67 129 191 258 320 382 448 r. 511 575 u 640 Input Current @ 120V (A) 0.58 1.16 1.78 2.31 2.94 3.56 4.09 4.71 5.34 5.87 Input Current @ 208V (A) 0.33 0.63 0.93 1.27 1.57 1.87 2.22 2.52 2.8 3.14 Input Current @ 240V (A) 0.29 0.55 0.80 1.10 1.35 1.61 1.93 2.18 2.41 2.71 Input Current @ 277V (A) 0.25 0.48 0.70 0.96 1.18 1.39 1.69 1.90 2.09 2.36 Input Current @ 347V (A) 0.20 0.39 0.57 0.78 0.96 1.15 1.36 1.54 1.72 1.92 Input Current @ 480V (A) m.. 4000K Lumens 0.15 7,972 0.30 15,580 0.43 23,245 0.60 30,714 0.73 38,056 0.85 45,541 1.03 53,857 1.16 61,024 1.28 68,072 1.45 75,366 T2 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -GS B3 -UO -G5 B4 -UO -G5 B4 -UO -GS B4 -UO -G5 B4 -UO -G5 Lumens per Watt 119 121 122 119 119 119 120 119 118 118 400OK Lumens 8,462 16,539 24,680 32,609 40,401 48,348 57,176 64,783 72,266 80,010 T211 BUG Rating B1 -UO -G2 B2 -UO -G2 B3 -UO -G3 B3 -UG -G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4 -UG -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 126 128 129 126 126 127 128 127 126 125 4000K Lumens 8,125 15,879 23,693 31,307 38,787 46,417 54,893 62,197 69,381 76,818 T3 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 121 123 124 121 121 122 123 122 121 120 4000K Lumens 8,306 16,232 24,220 32,001 39,651 47,447 56,114 63,580 70,924 78,523 T311 BUG Rating BI -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 124 126 127 124 124 124 125 124 123 123 4000K Lumens 8,173 15,970 23,831 31,488 39,014 46,686 55,212 62,558 69,783 77,261 T4FT BUG Rating B1 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 122 124 125 122 122 122 123 122 121 121 4000K Lumens 8,067 15,764 23,522 31,080 38,510 46,082 54,499 61,751 68,881 76,263 T4W BUG Rating B2 -UO -G2 B3 -UO -G3 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UD -G5 B4 -UO -G5 B4 -UO -G5 B5 -UO -G5 Lumens per Watt 120 122 123 120 120 121 122 121 120 119 4000K Lumens 7,958 15,552 23,206 30,662 37,989 45,462 53,763 60,920 67,952 75,235 SI -2 BUG Rating B2 -UO -G3 B3 -UO -G3 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 119 121 121 119 119 119 120 119 118 118 4000K Lumens 8,124 15,877 23,690 31,302 38,784 46,410 54,885 62,189 69,372 76,805 SI -3 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UG -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UG -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 121 123 124 121 121 121 123 122 121 120 40OOK Lumens 7,719 15,085 22,510 29,741 36,850 44,097 52,148 59,089 65,913 72,977 SI -4 BUG Rating B1 -UO -G3 B2 -UO -G4 B2 -UO -G5 B3 -UG -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UG -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 115 117 118 115 115 115 116 116 115 114 4000K Lumens 8,380 16,375 24,436 32,287 40,003 47,870 56,610 64,144 71,552 79,221 5NQ BUG Rating B3 -UO -G1 B3 -UO -G2 B4 -UD -G2 B5 -UO -G2 B5 -UO -G3 B5 -UO -G3 BS -UO -G4 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 125 127 128 125 125 125 126 126 124 124 4000K Lumens 8,534 16,676 24,885 32,881 40,739 48,752 57,653 65,326 72,868 80,679 5MQ BUG Rating B3 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 BS -UO -GS B5 -UO -G5 BS -UO -GS B5 -UO -G5 Lumens per Watt 127 129 130 127 127 128 129 128 127 126 4000K Lumens 8,556 16,723 24,951 32,968 40,847 48,881 57,808 65,499 73,063 80,894 5WQ BUG Rating B3 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 BS -UO -GS BS -UD -GS BS -UO -GS BS -UO -GS B5 -UO -G5 Lumens per Watt 128 130 131 128 128 128 129 128 127 126 4000K Lumens 7,140 13,951 20,817 27,506 34,081 40,783 48,231 54,649 60,959 67,492 SLL/ SLR BUG Rating B1 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UD -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 107 108 109 107 107 107 108 107 106 105 4000K Lumens 8,304 16,228 24,215 31,994 39,641 47,437 56,100 63,566 70,907 78,504 RW BUG Rating B3 -UO -G1 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UG -G4 BS -UO -GS BS -UO -GS Lumens per Watt 124 126 127 124 124 124 125 124 123 123 4000K Lumens 8,335 16,287 24,302 32,110 39,784 47,610 56,303 63,796 71,163 78,790 AFL BUG Rating B1 -UO -G1 B2 -UO -G2 B3 -UO -G2 B3 -UG -G3 B3 -UO -G3 B3 -UO -G3 B4 -UO -G4 B4 -UG -G4 B4 -UO -G4 64 -UO -GS Lumens per Watt 124 126 127 124 124 125 126 125 124 123 Nominal data for 70 CRI. - For additional performance data, please reference the Galleon Supplemental Performance Guide. COOPER so Lighting Solutions Octolw i 20, 2021 ca 311 lUVI Nominal Power Lumens (1 A) . ' � � dw" W�'I ",�"',uy^ry a Nominal Power (Watts) '.. wr 59 hull ' 113 166 "I 225 "ME 279 li 333 ... 391 I" 445 II i B ° 501 558 Input Current @ 120V (A) 0.51 1.02 1.53 2.03 2.55 3.06 3.56 4.08 4.60 5.07 Input Current @a 208V (A) 0.29 0.56 0.82 1.11 1.37 1.64 1.93 2.19 2.46 2.75 Input Current @ 240V (A) 0.26 0.48 0.71 0.96 1.19 0.41 1.67 1.89 2.12 2.39 Input Current @ 277V (A) 0.23 0.42 0.61 0.83 1.03 1.23 1.45 1.65 1.84 2.09 Input Current @ 347V (A) 0.17 0.32 0.50 0.64 0.82 1.00 1.14 1.32 1.50 1.68 Input Current @c 480V (A) 4000K Lumens 0.14 7,267 0.24 14,201 0.37 21,190 0.48 28,000 0.61 34,692 0.75 41,515 0.91 49,096 0.99 55,627 1.12 62,053 1.28 68,703 T2 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G3 B3 -U0 -G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 123 126 128 124 124 125 126 125 124 123 4000K Lumens 7,715 15,077 22,497 29,725 36,829 44,073 52,122 59,056 65,876 72,937 T211 BUG Rating B1 -UO -G2 B2 -UO -G2 B3-1JO-G3 B3 -UG -G3 B3 -UO -G4 B3 -UO -G4 B3-1JO-G5 B4 -UG -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 131 133 136 132 132 132 133 133 131 131 4000K Lumens 7,408 14,475 21,598 28,539 35,358 42,313 50,039 56,698 63,246 70,024 T3 BUG Rating B1 -UO -G2 B2 -UO -G2 B3-1JO-G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B4-1JO-G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 126 128 130 127 127 127 128 127 126 125 4000K Lumens 7,571 14,798 22,078 29,172 36,145 43,253 51,153 57,959 64,653 71,581 T311 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 128 131 133 130 130 130 131 130 129 128 4000K Lumens 7,451 14,559 21,725 28,703 35,564 42,558 50,330 57,027 63,613 70,430 T4FT BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4-1JO-G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 126 129 131 128 127 128 129 128 127 126 4000K Lumens 7,354 14,371 21,442 28,333 35,105 42,007 49,681 56,291 62,792 69,521 T4W BUG Rating B1 -UO -G2 B2 -UO -G3 B3-1JO-G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4-1JO-G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 125 127 129 126 126 126 127 126 125 125 4000K Lumens 7,254 14,178 21,155 27,951 34,631 41,443 49,011 55,533 61,944 68,584 SI -2 BUG Rating B1 -UO -G2 B2 -UO -G3 B3-1JO-G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4-1JO-G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 123 125 127 124 124 124 125 125 124 123 4000K Lumens 7,406 14,474 21,596 28,534 35,355 42,307 50,033 56,690 63,237 70,014 SI -3 BUG Rating B1 -UO -G2 B2 -UO -G3 B3-1JO-G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3-1JO-G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 126 128 130 127 127 127 128 127 126 125 4000K Lumens 7,037 13,751 20,519 27,112 33,592 40,198 47,538 53,864 60,087 66,524 SI -4 BUG Rating B1 -UO -G3 B2 -UO -G4 B2-1JO-G5 B3 -UG -G5 B3 -UO -G5 B3 -UO -G5 B3-1JO-G5 B3 -UG -G5 B3 -UO -G5 B4 -UO -G5 Lumens per Watt 119 122 124 120 120 121 122 121 120 119 4000K Lumens 7,640 14,928 22,275 29,431 36,465 43,637 51,606 58,472 65,226 72,218 5NQ BUG Rating B3 -UO -G1 B3 -UO -G2 B4-1JO-G2 B5 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5-1JO-G4 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 129 132 134 131 131 131 132 131 130 129 4000K Lumens 7,779 15,203 22,684 29,973 37,137 44,441 52,555 59,549 66,427 73,545 5MQ BUG Rating B3 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 BS -UO -GS B5 -UO -G5 B5 -UO -G5 B5 -UO -G5 Lumens per Watt 132 135 137 133 133 133 134 134 133 132 4000K Lumens 7,800 15,243 22,744 30,052 37,236 44,560 52,697 59,708 66,603 73,742 5WQ BUG Rating B3 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G5 B5-1JO-G5 B5 -UO -G5 B5 -UO -G5 B5 -UO -G5 Lumens per Watt 132 135 137 134 133 134 135 134 133 132 4000K Lumens 6,510 12,719 18,977 25,075 31,067 37,176 43,967 49,817 55,569 61,525 SLL/ SLR BUG Rating B1 -UO -G2 B2 -UO -G3 B2-1JO-G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3-1JO-G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 110 113 114 111 111 112 112 112 111 110 4000K Lumens 7,570 14,793 22,073 29,165 36,137 43,243 51,140 57,945 64,637 71,564 RW BUG Rating B3 -UO -G1 B4 -UO -G2 B4-1JO-G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5-1JO-G4 B5 -UO -G4 B5 -UO -G4 B5 -UO -G5 Lumens per Watt 128 131 133 130 130 130 131 130 129 128 4000K Lumens 7,598 14,847 22,154 29,272 36,267 43,400 51,326 58,156 64,872 71,824 AFL BUG Rating B1 -UO -G1 B2 -UO -G2 B3-1JO-G2 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 B4-1JO-G4 B4 -UO -G4 B4 -UO -G4 B4 -UO -G4 Lumens per Watt 129 131 133 130 130 130 131 131 129 129 Nominal data for 70 CRI. - For additional performance data, please reference the Galleon Supplemental Performance Guide. COOPER 91 u birlrlr2aimq�a�, �� Lighting Solutions Octolw i 20, 2021 ca 311 AIS Nominal Power Lumens (800mA) Nominal Power (Watts) .................................................................................................................................................................................................................. Input Current @ 120V (A) .................................................................................................................................................................................................................. Input Current @ 208V (A) .................................................................................................................................................................................................................. Input Current @ 240V (A) .................................................................................................................................................................................................................. Input Current @ 277V (A) .................................................................................................................................................................................................................. Input Current @ 347V (A) ........................................................................................................................................................ Input Current @ 480V (A) lltlMEMEMMEMEMEMEMEEM 4000K Lumens 44 0.39 0.22 0.19 0.17 0.15 0.11 5,871 85 0.77 0.44 0.38 0.36 0.24 0.18 11,474 III 124 .......................................................... 1.13 .......................................................... 0.62 .......................................................... 0.54 .......................................................... 0.47 .......................................................... 0.38 .......................................................... 0.29 17,121 171 1.54 0.88 0.76 0.72 0.49 0.37 22,622 210 .......................................................... 1.90 .................................................................................................................... 1.06 .......................................................... 0.92 .................................................................................................................... 0.83 .......................................................... 0.63 .................................................................................................................... 0.48 28,029 249 2.26 1.24 1.08 0.95 0.77 0.59 NONE= 33,542 295 .......................................................... 2.67 1.50 .......................................................... 1.30 1.19 .......................................................... 0.87 0.66 39,667 334 3.03 .......................................................... 1.68 1.46 .......................................................... 1.31 1.01 .................................................................................................................... 0.77 44,944 374 ............................................................... 3.39 1.87 ............................................................... 1.62 1.42 ............................................................... 1.15 0.88 NONE= 50,134 u 419 3.80 2.12 1.84 1.67 1.52 0.96 55,508 T2 BUG Rating B1 -UO -G2 B2 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -GS B4 -UO -G5 B4 -UO -G5 Lumens per Watt 133 135 138 132 133 135 134 135 134 132 4000K Lumens 6,233 12,181 18,176 24,016 29,756 35,608 42,111 47,714 53,224 58,929 T211 BUG Rating B1 -UO -G1 B2 -UO -G2 B2 -UO -G2 B3 -UO -G3 B3 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 Lumens per Watt 142 143 147 140 142 143 143 143 142 141 4000K Lumens 5,986 11,695 17,450 23,057 28,568 34,186 40,430 45,809 51,099 56,576 T3 BUG Rating B1 -UO -G2 B2 -UO -G2 B3 -UO -G3 B3 -UG -G4 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B4 -UG -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 136 138 141 135 136 137 137 137 137 135 4000K Lumens 6,117 11,955 17,838 23,569 29,203 34,946 41,328 46,827 52,235 57,832 T311 BUG Rating B1 -UO -G2 B2 -UO -G2 B2 -UO -G3 133 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 139 141 144 138 139 140 140 140 140 138 4000K Lumens 6,019 11,763 17,551 23,190 28,734 34,384 40,663 46,074 51,396 56,904 T4FT BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 137 138 142 136 137 138 138 138 137 136 4000K Lumens 5,942 11,610 17,324 22,891 28,363 33,940 40,138 45,480 50,732 56,169 T4W BUG Rating B1 -UO -G2 B2 -UO -G2 B3 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 135 137 140 134 135 136 136 136 136 134 4000K Lumens 5,862 11,454 17,091 22,583 27,980 33,484 39,598 44,867 50,048 55,411 SI -2 BUG Rating B1 -UO -G2 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 133 135 138 132 133 134 134 134 134 132 4000K Lumens 5,985 11,694 17,447 23,053 28,565 34,182 40,424 45,804 51,092 56,568 SI -3 BUG Rating B1 -UO -G2 B2 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 Lumens per Watt 136 138 141 135 136 137 137 137 137 135 4000K Lumens 5,685 11,111 16,577 21,905 27,140 32,478 38,409 43,520 48,546 53,748 SI -4 BUG Rating B1 -UO -G2 B1 -UO -G3 B2 -UO -G4 B2 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 129 131 134 128 129 130 130 130 130 128 4000K Lumens 6,172 12,061 17,997 23,778 29,462 35,256 41,694 47,242 52,699 58,347 5NQ BUG Rating B2 -UO -G1 B3 -UO -G1 B4 -UO -G2 B4 -UG -G2 B5 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UG -G3 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 140 142 145 139 140 142 141 141 141 139 4000K Lumens 6,285 12,283 18,328 24,217 30,004 35,907 42,462 48,112 53,669 59,421 5MQ BUG Rating B3 -UO -G1 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UG -G4 B5 -UO -G5 B5 -UO -G5 Lumens per Watt 143 145 148 142 143 144 144 144 144 142 4000K Lumens 6,303 12,317 18,377 24,281 30,085 36,001 42,575 48,241 53,812 59,579 5WQ BUG Rating B3 -UO -G1 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G5 B5 -UO -G5 B5 -UO -G5 BS -UO -GS Lumens per Watt 143 145 148 142 143 145 144 144 144 142 4000K Lumens 5,260 10,276 15,332 20,259 25,101 30,037 35,522 40,249 44,898 49,708 SLL/ SLR BUG Rating B1 -UO -G2 B2 -UO -G3 B2 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 120 121 124 118 120 121 120 121 120 119 4000K Lumens 6,116 11,952 17,834 23,563 29,196 34,938 41,317 46,817 52,224 57,819 RW BUG Rating B3 -UO -G1 B3 -UO -G2 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 139 141 144 138 139 140 140 140 140 138 4000K Lumens 6,139 11,996 17,899 23,650 29,302 35,064 41,468 46,987 52,412 58,030 AFL BUG Rating B1 -UO -G1 B2 -UO -G2 B2 -UO -G2 B3 -UO -G2 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 B4 -UO -G4 B4 -UO -G4 Lumens per Watt 140 141 144 138 140 141 141 141 140 138 Nominal data for 70 CRI. - For additional performance data, please reference the Galleon Supplemental Performance Guide. COOPER s2 u birlriraimq�a�,� Lighting Solutions Octolw i 20, 2021 ca 311 AIS Nominal Power Lumens (600mA) " III ".'.J Billii i Nominal Power (Watts) ............................................................................................................................................................................................. Input Current @ 120V (A) ............................................................................................................................................................................................. Input Current @ 208V (A) ............................................................................................................................................................................................. Input Current @ 240V (A) .................................................................................................................................................................................................................. Input Current @ 277V (A) .................................................................................................................................................................................................................. Input Current @ 347V (A) ........................................................................................................................................................ Input Current @ 480V (A) lltl 4000K Lumens Illlllliii' 4 0.30 0.17 70.1570.30 0.15 0.14 0.11 0.08 4,787 66 0.58 0.34 0.30 0.28 0.19 0.15 9,357 III 96 .......................................................... 0.86 .......................................................... 0.49 .......................................................... 0.43 .......................................................... 0.41 .......................................................... 0.30 .......................................................... 0.24 13,961 129 1.16 0.65 0.56 0.52 0.39 0.30 18,448 162 .......................................................... 1.44 .................................................................................................................... 0.84 .......................................................... 0.74 .................................................................................................................... 0.69 .......................................................... 0.49 .................................................................................................................... 0.38 22,856 193 1.73 0.99 0.87 0.81 0.60 0.48 27,353 226 .......................................................... 2.03 1.14 .......................................................... 1.00 0.93 .......................................................... 0.69 0.53 32,347 257 2.33 .......................................................... 1.30 1.13 .......................................................... 1.04 0.77 .................................................................................................................... 0.59 36,651 290 ............................................................. 2.59 1.48 ............................................................. 1.30 1.22 ............................................................. 0.90 0.71 40,884 u 323 2.89 1.63 1.43 1.33 0.99 0.77 45,265 T2 BUG Rating B1 -UO -G1 B2 -UO -G2 B2 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G4 B3 -UO -GS B3 -UO -G5 B3 -UO -G5 Lumens per Watt 141 142 145 143 141 142 143 143 141 140 4000K Lumens 5,083 9,934 14,822 19,585 24,266 29,038 34,341 38,911 43,404 48,055 T211 BUG Rating B1 -UO -G1 B1 -UO -G2 B2 -UO -G2 B2 -UO -G2 B3 -UO -G3 B3 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 Lumens per Watt 150 151 154 152 150 150 152 151 150 149 4000K Lumens 4,880 9,537 14,231 18,803 23,296 27,878 32,970 37,358 41,671 46,137 T3 BUG Rating B1 -UO -G1 B2 -UO -G2 B2 -UO -G2 B3 -UG -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G4 B3 -UG -G5 B3 -UO -G5 B4 -UO -G5 Lumens per Watt 144 145 148 146 144 144 146 145 144 143 4000K Lumens 4,988 9,749 14,547 19,220 23,814 28,497 33,703 38,188 42,598 47,162 T311 BUG Rating B1 -UO -G2 B1 -UO -G2 B2 -UO -G3 132 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 147 148 152 149 147 148 149 149 147 146 4000K Lumens 4,909 9,591 14,312 18,911 23,432 28,040 33,161 37,574 41,913 46,404 T4FT BUG Rating B1 -UO -G2 B2 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 Lumens per Watt 144 145 149 147 145 145 147 146 145 144 4000K Lumens 4,845 9,468 14,128 18,668 23,130 27,678 32,732 37,088 41,371 45,805 T4W BUG Rating B1 -UO -G2 B2 -UO -G2 B2 -UO -G3 B3 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 143 143 147 145 143 143 145 144 143 142 4000K Lumens 4,779 9,341 13,937 18,416 22,818 27,305 32,292 36,589 40,813 45,188 SI -2 BUG Rating B1 -UO -G2 B2 -UO -G3 B2 -UO -G3 B3 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B4 -UO -G5 B4 -UO -G5 Lumens per Watt 141 142 145 143 141 141 143 142 141 140 4000K Lumens 4,879 9,536 14,229 18,800 23,294 27,874 32,965 37,351 41,666 46,130 SI -3 BUG Rating B1 -UO -G2 B1 -UO -G3 B2 -UO -G3 B2 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 144 144 148 146 144 144 146 145 144 143 4000K Lumens 4,637 9,059 13,519 17,863 22,132 26,486 31,322 35,490 39,589 43,831 SI -4 BUG Rating B1 -UO -G2 B1 -UO -G3 B2 -UO -G4 B2 -UO -G4 B2 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 136 137 141 138 137 137 139 138 137 136 4000K Lumens 5,033 9,835 14,676 19,392 24,026 28,751 34,002 38,526 42,975 47,581 5NQ BUG Rating B2 -UO -G1 B3 -UO -G1 B3 -UO -G2 B4 -UG -G2 B4 -UO -G2 B4 -UO -G2 B5 -UO -G2 B5 -UG -G3 B5 -UO -G3 B5 -UO -G3 Lumens per Watt 148 149 153 150 148 149 150 150 148 147 4000K Lumens 5,126 10,015 14,946 19,747 24,468 29,281 34,628 39,236 43,766 48,457 SNIQ BUG Rating B3 -UO -G1 B3 -UO -G2 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 151 152 156 153 151 152 153 153 151 150 4000K Lumens 5,139 10,043 14,985 19,801 24,533 29,359 34,721 39,339 43,883 48,586 5WQ BUG Rating B3 -UO -G1 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 B5 -UO -G4 B5 -UO -G5 B5 -UO -G5 Lumens per Watt 151 152 156 153 151 152 154 153 151 150 4000K Lumens 4,289 8,380 12,502 16,520 20,469 24,494 28,967 32,823 36,613 40,537 SLL/ SLR BUG Rating B1 -UO -G2 B1 -UO -G3 B2 -UO -G3 B2 -UO -G4 B3 -UO -G4 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 B3 -UO -G5 Lumens per Watt 126 127 130 128 126 127 128 128 126 126 4000K Lumens 4,987 9,746 14,543 19,215 23,808 28,491 33,695 38,178 42,587 47,151 RW BUG Rating B2 -UO -G1 B3 -UO -G1 B4 -UO -G2 B4 -UO -G2 B4 -UO -G2 B5 -UO -G3 B5 -UO -G3 B5 -UO -G3 B5 -UO -G4 B5 -UO -G4 Lumens per Watt 147 148 151 149 147 148 149 149 147 146 4000K Lumens 5,007 9,782 14,597 19,285 23,896 28,594 33,817 38,317 42,742 47,322 AFL BUG Rating B1 -UO -G1 B1 -UO -G1 B2 -UO -G2 B2 -UO -G2 B3 -UO -G2 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 B3 -UO -G3 Lumens per Watt 147 148 152 149 148 148 150 149 147 147 Nominal data for 70 CRI. ** For additional performance data, please reference the Galleon Supplemental Performance Guide. COOPER s3 �IIVVVIW�"" L.,�watYfYIYJ(YI':I'9 p»mgpa�"rD Lighting Solutions Octolw i 20, 2021 ca 311 AIS c c� 11111114111%) l Q"3'iakxurli ANN 0-10V (DIM) This fixture is offered standard with 0-1 OV dimming driver(s). The DIM option provides 0-10V dimming wire leads for use with a lighting control panel or other control method Photocontrol (BPC, PR and PR7) Optional button -type photocontrol (BPC) and photocontrol receptacles (PR and PR7) provide a flexible solution to enable "dusk-to-dawn"lighting by sensing light levels. Advanced control systems compatible with NEMA 7 -pin standards can be utilized with the PR7 receptacle. After Hours Dim (AHD) This feature allows photocontrol-enabled luminaires to achieve additional energy savings by dimming during scheduled portions of the night. The dimming profile will automatically take effect after a "dusk -to -dawn" period has been calculated from the photocontrol input. Specify the desired dimming profile for a simple, factory -shipped dimming solution requiring no external control wiring. Reference the After Hours Dim supplemental guide for additional information. Dimming Occupancy Sensor (SPB, MS/DIM-LXX, MS/X-LXX and MS -LXX) These sensors are factory installed in the luminaire housing. When the SPB or MS/DIM sensor options are selected, the occupancy sensor is connected to a dimming driver and the entire lumi- naire dims when there is no activity detected. When activity is detected, the luminaire returns to full light output. The MS/DIM sensor is factory preset to dim down to approximately 50 percent power with a time delay of five minutes. The MS -LXX sensor is factory preset to turn the luminaire off after five minutes of no activity. The MS/X-LXX is also preset for five minutes and only con- trols the specified number of light engines to maintain steady output from the remaining light engines. SPB motion sensors require the Sensor Configuration mobile application by Wattstopper to change factory default dimming level, time delay, sensitivity and other parameters. Available for iOS and Android devices. The SPB sensor is factory preset to dim down to approximately 10% power with a time delay of five minutes. The MS/DIM occupancy sensors require the FSIR-100 programming tool to adjust factory defaults. For mounting heights up to 8' (-L08) 0 r wr e„w nm m �mnaj 8 mamju 12 lVp0ii�yyNl0 �� FN1V11Nh81\VVNO 36 24 18 7 5 0 5 7 18 24 36 Coverage Side Area (Feet) For mounting heights up to 40' (-L40W) 0 n dp �� 0A tliw�. For mounting heights up to 20' (-L20) 20 18 15 12 9 6 3 0 3 6 9 12 15 18 20 Enlighted Wireless Control and Monitoring System (LWR-LW and LWR-LN) Enlighted is a connected lighting solution that combines a broad selection of energy-efficient LED luminaires with a powerful integrated wireless sensor system. The sensor controls the lighting system in compliance with the latest energy codes and collects valuable data about building performance and use. Software applications turn the granular data into information through energy dashboards and specialized apps that make it simple and help optimize the use of building resources, beyond lighting. For mounting heights from 8' to 16' (LWR-LW) For mounting heights from 16' to 40' (LWR-LN) 20- 30- 40 30 20 10 0 10 20 30 40 Coverage Side Area ( Feet) Coverage Side Area ( Feet) WaveLinx Wireless Outdoor Lighting Control Module (WOLC-7P-10A) The 7 -pin wireless outdoor lighting control module enables Wave Linx to control outdoor area, site and flood lighting. Wave Linx controls outdoor lighting using schedules to provide ON, OFF and dimming controls based on astronomic or time schedules based on a 7 day week. LumenSafe Integrated Network Security Camera (LD) Cooper Lighting Solutions brings ease of camera deployment to a whole new level. No additional wiring is needed beyond providing line power to the luminaire. A variety of networking options allows security integrators to design the optimal solution for active surveillance. As the ideal solution to meet the needs for active surveillance, the LumenSafe integrated network camera is a streamlined, outdoor -ready fixed dome that provides HDTV 1080p video. This IF camera is optimally designed for deployment in the video management system or security software platform of choice. Synapse (DIM10) SimplySNAP integrated wireless controls system by Synapse. Includes factory installed DIM10 Synapse control module and MS/DC motion sensor, requires additional Synapse system components for operation. Contact Synapse at wv w.s.. apsewireless com for product support, warranty and terms and conditions. Cooper Lighting Solutions � 2021 Cooper Lighting Solutions COOPER 1121Hfighway748ouAll Rights PeeiveL 94 III�II�O Peachtree City GA 3026e P. 771486-4800 Specifications and dimensions I""swtatYf YIYJ(YI I'g page 1p Lighting Solutions wwwcoopedighting.com subject tochangewithoutnotice . Ch,Pol) i 20, 202t CJ 311AlVI 56 U O O D awO } N O' :. ¢ i LI l i U W U N S of Q z J� O aw O J a ��< W S Z d �v ¢ o m 1 o '() D � O� w p w � Q Of p 00 TLJ x z ¢ J N < +\ Ln O !n OoN W O J ^� a OZQ 0a 0 Q N Z� J O U ZWw m r� O Of .. 'O J ( p U) W �dx 9. x ryvM�, W O� !n �� W J 3 O a' W 0 —Z 0 p f! ZO ~p O 07 o cn ; O Q L_______ ________ ____ 00 O 'w O w Z J x J U0 oZ ,Q \ Qoa Z w JOu7 f U W O Z a < Ka -) W Oa wmU Se O a vdo ¢ cO o I W W I I p I J 0zQ x3� �o16-0 m \ m J p pccCD x Z Y Q NO CE W a O W K a W - J O W = O oZ Z U U p Ix N) m Z - ONrc I [O W � In m z z w N LLJ ~ aFiwamo Or - ka�zmm�NQ J Q Z r) o p O O z a - < Q mi - =3Of wU� �im��amzw�;z Z_O v_viz3 �roo W W j W(n co Cip(n Y N �+� �_ YzO `?'�a'a iHE _W (if�a O W �3mr to �cmio H p U Z a � w3of=Yrcw��F Z aZ = O� rco�Torcc�ao o ax ow z��o p - J W Ci0 V) w Z ¢ Z U W O J H p O w } _ co O Z cn Ww O HU U W Q g Ld (") a s a � ozQ I w 00 � x cr ¢ J J a Z ¢ O W0 p m g } �p �p � _ aLJJ (n (D p Z 00 I (-p'0 Q H m O, 3Q 3¢D a J J p LLJQ NV) vw)g ¢� Q�g Y 'L' p a O W W J D + m ..... - (o p z z a (�O � � L L J W Z ° ¢ Q Q Q w o - co :2:2 � 0 H _______ _______ ____. O Z a Q x K H 0 x o r O Z W - Z Y Z Z-0 Y Li Z O N av)0 �Cn0 N W O H (gip V1 HLA \ Q O QLLJ m KD JU(n J U K LLJM N J Q ma(n Z x J cn m p U Z zw a Cif J Z a O W OOQ OOQ V Z � w L J j OZ Q �a W 0 U) W Z 0 V o U Z Z 7 W a w Q a L` q-Lu0 �H �w -t _ J ---------------------- Cep (~!) N =M � CV Z V N Z Z [O (n O z m V Q m ?� X p W J p O I+) Z J 3 � o � J O X a X O} 7 O O N Z � W � OO W x Z W O d O Z � � �� x � o_ � � H I � Q (n (O x z g m W N Z w m O r\jo w � a g � w W Y N x w ~ LL w m � w � a O D Z O > m Z !n � � p H F J O J � Y (7 [ifO W Z ow UO - H Z N �� {.:: // \\I\ O Z x O � W J U J x LL, J �� W W B U J U w tnx ¢ �O O 3 �}o a p Q C) H Z m p p i �� N\ a � x In �� � 3z a a a �dN �_ OJQ � m \( Q � Q Z U (n Z �\m O OYD YZ ZOH l() U x (n CQ.� aa Z a x O- w I O Z Y ll -l -l -1-l- -1-T j l-T-�I Z Z Q Z p Z S Z�� � � � Z(n ZO ¢ U a 00¢ I� ~ W a �n p p W aJ %F JI_J_J_1_J _J_1!�_1_�1 p H= / w Z � S ¢ U � O e H Z H WO � � � � � cn d'p a(n W M W a' �x H W J So a. o - p p a ULLJ N � J w � � zw ZH � I I �zw � 4 a U w � oaIz O 3 z3 ?oom�o�o_m (n W' U W H � WJ d CO Z U p w =LLJ U)C14 I) O J K Lj W J Z~ � Z Op m U� � I� U) U m w= v>m��Q zoQ 0 w Q N p o 0 o wa O �� (O a O -_ XU\�O Z Ln 0 � m Z Q W W j W � O v OJ * `-' `-' x o J N O Ori O W Y z H I Z Z d waniW N Ow �U�m� ¢ W�� = z a� � w Z U U ¢ Z z � H m z o�ZZo � ¢ Z w g 96 d •'y o \ a ¢ F Fp a J U � Z Z w Z ¢ z ¢J 0m -0 p z �¢ ¢ p � IMM o c� w S ¢ J v� Q w Z W W m w _mss. w —t- Z D O m S, U Uxl x ¢ N U O x O'00 O o an Lo o 30 _� �d = F J 7 - O tiirry OV z J Q O a C \_ �J s9 ¢ �H bs wG� z O O W H z f U O W W a In V I U d O 7� n � � c�H BMW w J� ¢w N N x2 KU F W W K j O' lwiU N I v¢ to I 0 m p F 2 N x JQ@ V _ N i..JX xN' H(n ZZD ZO MQ� 1' Z a- a w p ¢w rw, I I J N J s n I I - N a m� v Z � GLuI a < W J z CaJ Y Z Y 5 CD Z Z In a � w z w a 0 w z w m � W p �wz m m 9 z=~ m m I X w 0 z\a V W 0 v2 N V �N¢ o ¢ m m WSJ = 0 m Q2 N¢Zrj J_ W Lic � z N p ¢w� 131' ¢ U w m z z m O z U ¢ N O Q~ K H (n � a PERFORMANCE DATAPM84481 March 30, 2018 POWER HATH FAN LOAD POWER TO JACKET WATER TO ATMOSPHERE TO EXH RECOVERY TO35OF COOLER STAGE ENERGY AFTERCOOLER VALUE ENERGY VALUE ENERGY EKW % BHP BTU/MIN BTU/MIN BTU/MIN BTU/MIN BTU/MIN BTU/MIN BTU/MIN BTU/MIN BTU/MIN 3,000.0 100 4,423 78,436 8,336 179,063 101,475 24,486 28,224 187,548 459,719 489,716 2,700.0 90 3,999 70,525 7,773 161,695 89,988 22,085 23,040 169,590 414,639 441,694 2,400.0 80 3,576 63,777 7,308 147,071 80,799 19,915 18,972 151,631 373,899 398,296 2,250.0 75 3,364 60,840 7,112 140,788 77,146 18,917 17,358 142,651 355,157 378,331 2,100.0 70 3,152 58,599 6,984 136,398 74,726 18,070 16,328 133,672 339,264 361,402 1,800.0 60 2,729 54,754 6,750 128,972 70,419 16,496 14,928 115,714 309,709 329,917 1,500.0 50 2,305 50,870 6,524 120,720 65,533 14,875 13,738 97,755 279,270 297,493 1,200.0 40 1,882 45,639 6,304 106,679 55,828 12,823 11,188 79,796 240,744 256,453 900.0 30 1,458 38,952 6,092 88,655 45,754 10,475 8,227 61,838 196,664 209,497 750.0 25 1,246 35,102 5,988 78,431 40,805 9,211 6,848 52,858 172,945 184,229 600.0 20 1,035 30,773 5,789 67,509 34,336 7,896 5,681 43,879 148,253 157,927 300.0 10 611 20,277 4,828 43,873 17,588 5,132 4,028 25,920 96,361 102,649 Sound Data SOUND DATA REPRESENTATIVE OF NOISE PRODUCED BY THE "ENGINE ONLY" EXHAUST: Sound Power (1/3 Octave Frequencies) GENSET POWER WITH FAN PERCENT LOAD ENGINE POWER OVERALL SOUND 100 HZ 125 HZ 160 HZ 200 HZ 250 HZ 315 HZ 400 HZ 500 HZ 630 HZ EKW % BHP dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) 3,000.0 100 4,423 134.5 109.7 115.8 113.7 115.5 116.0 119.0 119.9 121.5 120.4 2,700.0 90 3,999 133.2 110.2 116.1 112.6 114.3 114.5 117.3 118.4 120.1 118.3 2,400.0 80 3,576 132.0 111.6 116.6 111.0 112.7 113.0 115.6 116.9 118.4 116.5 2,250.0 75 3,364 131.4 112.4 116.8 110.2 111.9 112.3 114.8 116.2 117.6 115.6 2,100.0 70 3,152 130.7 113.2 117.1 109.3 111.1 111.6 114.0 115.5 116.8 114.7 1,800.0 60 2,729 129.5 114.8 117.6 107.5 109.4 110.2 112.3 114.1 115.1 113.0 1,500.0 50 2,305 128.2 116.3 118.1 105.8 107.8 108.7 110.6 112.6 113.4 111.2 1,200.0 40 1,882 127.0 117.9 118.6 104.1 106.1 107.3 108.9 111.2 111.8 109.5 900.0 30 1,458 125.7 119.5 119.1 102.3 104.4 105.9 107.3 109.8 110.1 107.7 750.0 25 1,246 125.1 120.2 119.3 101.4 103.6 105.2 106.4 109.1 109.3 106.8 600.0 20 1,035 124.4 121.0 119.6 100.6 102.8 104.5 105.6 108.4 108.4 105.9 300.0 10 611 123.2 122.6 120.0 98.8 101.1 103.0 103.9 106.9 106.8 104.2 EXHAUST: Sound Power (1/3 Octave Frequencies) GENSET POWER WITH FAN PERCENT LOAD ENGINE POWER 1000 HZ 1250 HZ 1600 HZ 2000 HZ 2500 HZ 3150 HZ 4000 HZ 5000 HZ 6300 HZ 8000 HZ EKW % BHP dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) 3,000.0 100 4,423 122.2 122.6 123.5 124.9 124.7 123.1 122.4 121.6 120.1 119.0 2,700.0 90 3,999 120.7 121.0 122.2 123.5 123.2 121.5 120.8 120.0 118.7 117.8 2,400.0 80 3,576 119.4 119.7 120.8 122.5 121.9 120.4 119.8 119.0 117.7 117.1 2,250.0 75 3,364 118.8 119.1 120.1 122.0 121.3 119.9 119.4 118.6 117.2 116.8 2,100.0 70 3,152 118.1 118.5 119.4 121.5 120.6 119.3 119.0 118.2 116.7 116.5 1,800.0 60 2,729 116.9 117.3 118.0 120.4 119.4 118.3 118.1 117.3 115.6 115.9 1,500.0 50 2,305 115.6 116.2 116.6 119.4 118.1 117.3 117.2 116.4 114.6 115.3 1,200.0 40 1,882 114.3 115.0 115.1 118.4 116.8 116.3 116.4 115.6 113.6 114.7 900.0 30 1,458 113.1 113.8 113.7 117.4 115.6 115.3 115.5 114.7 112.6 114.1 750.0 25 1,246 112.4 113.2 113.0 116.9 114.9 114.8 115.1 114.3 112.1 113.8 600.0 20 1,035 111.8 112.6 112.3 116.4 114.3 114.2 114.7 113.9 111.6 113.5 300.0 10 611 110.5 111.4 110.9 115.4 113.0 113.2 113.8 113.0 110.6 112.9 Sound Data (Continued) MECHANICAL: Sound Power (1/3 Octave Frequencies) GENSET POWER WITH FAN PERCENT LOAD ENGINE POWER OVERALL SOUND 100 HZ 125 HZ 160 HZ 200 HZ 250 HZ 315 HZ 400 HZ 500 HZ 630 HZ EKW % BHP dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) 3,000.0 100 4,423 125.9 89.8 105.6 98.4 100.6 104.5 108.3 111.6 113.3 112.5 2,700.0 90 3,999 125.8 89.4 105.5 97.9 100.9 103.3 108.7 111.1 112.7 112.2 2,400.0 80 3,576 126.0 89.0 105.0 97.8 99.8 102.4 108.0 111.0 111.8 111.9 2,250.0 75 3,364 126.1 88.8 104.7 97.8 99.1 102.1 107.5 111.0 111.3 111.7 Page 2 of 6 Page 38 of 158 97 PERFORMANCE DATAPM84481 March 30, 2018 2,100.0 70 3,152 126.2 88.5 104.3 97.8 98.4 101.7 107.0 111.0 110.8 111.6 1,800.0 60 2,729 126.5 88.1 103.7 97.8 96.9 100.9 106.0 111.0 109.8 111.2 1,500.0 50 2,305 126.7 87.7 103.0 97.8 95.4 100.2 105.1 111.0 108.8 110.9 1,200.0 40 1,882 127.0 87.3 102.4 97.7 94.0 99.4 104.1 110.9 107.8 110.6 900.0 30 1,458 127.2 86.9 101.7 97.7 92.5 98.6 103.1 110.9 106.8 110.2 750.0 25 1,246 127.3 86.7 101.4 97.7 91.8 98.2 102.6 110.9 106.3 110.1 600.0 20 1,035 127.4 86.4 101.0 97.7 91.0 97.9 102.1 110.9 105.8 109.9 300.0 10 611 127.7 86.0 100.4 97.7 89.6 97.1 101.2 110.9 104.8 109.6 MECHANICAL: Sound Power (1/3 Octave Frequencies) GENSET POWER WITH FAN PERCENT LOAD ENGINE POWER 1000 HZ 1250 HZ 1600 HZ 2000 HZ 2500 HZ 3150 HZ 4000 HZ 5000 HZ 6300 HZ 8000 HZ EKW % BHP dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) 3,000.0 100 4,423 112.7 113.9 114.6 115.3 115.0 112.7 110.9 111.9 114.3 113.4 2,700.0 90 3,999 112.5 113.7 114.5 115.0 114.5 112.3 110.4 111.1 113.6 112.9 2,400.0 80 3,576 112.2 113.2 113.8 114.4 114.2 111.9 110.0 110.7 113.2 112.6 2,250.0 75 3,364 112.0 112.9 113.4 114.0 114.2 111.7 109.8 110.5 112.9 112.6 2,100.0 70 3,152 111.8 112.6 113.0 113.7 114.1 111.4 109.6 110.3 112.7 112.5 1,800.0 60 2,729 111.3 112.1 112.2 113.1 113.9 111.0 109.3 110.0 112.3 112.3 1,500.0 50 2,305 110.9 111.5 111.4 112.4 113.7 110.6 109.0 109.6 111.9 112.1 1,200.0 40 1,882 110.5 110.9 110.5 111.7 113.5 110.2 108.6 109.3 111.5 111.9 900.0 30 1,458 110.1 110.3 109.7 111.1 113.4 109.8 108.3 109.0 111.0 111.8 750.0 25 1,246 109.9 110.0 109.3 110.7 113.3 109.6 108.1 108.8 110.8 111.7 600.0 20 1,035 109.7 109.7 108.9 110.4 113.2 109.3 107.9 108.6 110.6 111.6 300.0 10 611 109.3 109.2 108.1 109.7 113.0 108.9 107.6 108.3 110.2 111.4 Emissions Data RATED SPEED POTENTIAL SITE VARIATION: 1800 RPM GENSET POWER WITH FAN EKW 3,000.0 2,250.0 1,500.0 750.0 300.0 PERCENT LOAD % 100 75 50 25 10 ENGINE POWER BHP 4,423 3,364 2,305 1,246 611 TOTAL NOX (AS NO2) G/HR 32,004 21,429 9,376 3,795 3,518 TOTAL CO G/HR 5,743 6,479 3,534 5,489 3,566 TOTAL HC G/HR 647 597 1,048 1,031 1,300 PART MATTER G/HR 210.2 221.1 203.5 409.7 343.1 TOTAL NOX (AS NO2) (CORR 5% 02) MG/NM3 3,736.7 3,329.4 1,866.7 1,263.6 2,259.3 TOTAL CO (CORR 5% 02) MG/NM3 586.2 854.4 602.3 1,594.3 1,701.1 TOTAL HC (CORR 5% 02) MG/NM3 54.2 69.1 157.2 265.0 625.2 PART MATTER (CORR 5% 02) MG/NM3 18.2 25.6 31.4 103.5 158.0 TOTAL NOX (AS NO2) (CORR 5% 02) PPM 1,820 1,621 909 616 1,101 TOTAL CO (CORR 5% 02) PPM 469 684 482 1,275 1,361 TOTAL HC (CORR 5% 02) PPM 101 129 294 495 1,167 TOTAL NOX (AS NO2) G/HP-HR 7.28 6.40 4.08 3.05 5.76 TOTAL CO G/HP-HR 1.31 1.93 1.54 4.41 5.84 TOTAL HC G/HP-HR 0.15 0.18 0.46 0.83 2.13 PART MATTER G/HP-HR 0.05 0.07 0.09 0.33 0.56 TOTAL NOX (AS NO2) LB/HR 70.56 47.24 20.67 8.37 7.75 TOTAL CO LB/HR 12.66 14.28 7.79 12.10 7.86 TOTAL HC LB/HR 1.43 1.32 2.31 2.27 2.87 PART MATTER LB/HR 0.46 0.49 0.45 0.90 0.76 RATED SPEED NOMINAL DATA: 1800 RPM GENSET POWER WITH FAN EKW 3,000.0 2,250.0 1,500.0 750.0 300.0 PERCENT LOAD % 100 75 50 25 10 ENGINE POWER BHP 4,423 3,364 2,305 1,246 611 TOTAL NOX (AS NO2) G/HR 26,670 17,858 7,813 3,162 2,931 TOTAL CO G/HR 3,190 3,599 1,963 3,050 1,981 TOTAL HC G/HR 486 449 788 776 977 TOTAL CO2 KG/HR 2,143 1,609 1,236 751 416 PART MATTER G/HR 150.1 157.9 145.3 292.7 245.1 TOTAL NOX (AS NO2) (CORR 5% 02) MG/NM3 3,113.9 2,774.5 1,555.6 1,053.0 1,882.8 TOTAL CO (CORR 5% 02) MG/NM3 325.6 474.7 334.6 885.7 945.0 TOTAL HC (CORR 5% 02) MG/NM3 40.7 51.9 118.2 199.3 470.1 PART MATTER (CORR 5% 02) MG/NM3 13.0 18.3 22.5 73.9 112.8 TOTAL NOX (AS NO2) (CORR 5% 02) PPM 1,517 1,351 758 513 917 Page 3 of 6 Page 39 of 158 98 99 O Ln Lo -1 m Lri o 00 00 00 a)00 r, w O Lr) Lo -1 m O O ri tj 4 .4 �t O 00 00 n -, O L(1 w -1 M O O Ol N O Ol Q 000 � O O U C C O Ln LO rl O M OM 00 LD } LD 00 rl m m 00 rl Q Ln N aJ 4' a-+ i aJ f0 OLn O w `0 rl m Ln -1 0 o rn ra 00 - -q E 0 �- � � Ln v aJ `� c > 4J v aJ Ll J O Ln E l.{J N -1" m Ln N ci Ln E m0 OJ .� m 3 v -1 -4 o > J SD > aJ L O a) Ln Ln N = J v N v a v � a v o O Ln a� Ln w ri v m m 00 ,o E L,o Ln N O O rn O N .� n LU LII C Ln t.0 m N 76 m (.D r -I O r -I O rt m U .41 N O LL N aJ O_ Ln LO rI M 0o m ri ri Q rI O O LT co r� rl rl O Z 99 (winur;Rt-60-1 Molommim= DKH . DIISK HOSPITAL WMIDE SILENCER TYPICAL ATTENUA71ON 34. 43 M(AM This disk silencer is desi cried fo,r equipment olire rat in gin very quiet envinowent a that require. an exceptional level of attenuation IN bw p f,e I ."de itself I—, ds prqcr , , 'Ith "Psi. III itati-S Af.Tcli-flDli -ILde stationary, i naitne, r -bile, etc G V1 , u Sa I Dra m I � 9 1, -- ------- ------ 10 Typca Aft—iat,n [Ai-, M mig—g), --------- --------- --- -------- -------- ffoffflffl 1111 . ................. I ..... . ......... . 100 44, M U Vw WaA, 3Yr 'Is vj rp"Ir , X?0�2 ....... ...... 'JI iii, 4i'll M) r, H Ph NO 1? 7K? r"Ji �A FF -fancrC-Q Rif M2 ii"aAlr 2 wl ..... ... ..... .. .. ..... . "4 'rn . 1ld 40 Typca Aft—iat,n [Ai-, M mig—g), --------- --------- --- -------- -------- ffoffflffl 1111 . ................. I ..... . ......... . 100 MIPRtECH Pay eIae or ..........;FiZ ........................................................................................................... 2 �-�-2 ......................................................................................... 12 " "EojWi" 101 P,.p-1 N-,bx, SMA 18-1239 Rev(2) (1-17 315 125 2.%m SP1W tk 2k 4 A (dBA Sol-- Al --m, R—g, 35-4C dBA Fl.. Fll.. R— W—hy F,.—D,.p I 1 29-1, C,ICFF22PF .... .... lea..C, :, bof C "k E,,d 11, Vl, 22'P 1 2 wj,— Lugo N!, P. ,, 29620 n, 1172f-/, 2. nH,u of fii Pay eIae or ..........;FiZ ........................................................................................................... 2 �-�-2 ......................................................................................... 12 " "EojWi" 101 This disk silencer is designed for equipment operating in very quiet environments that require an exceptional level of attenuation. Its low profile lends itself towards projects with space limitations. Applications include stationary, marine, mobile, etc. ji.�^. .... 61es....11;;Ir..y ii.inl.g S. D F Cl B 001 E� G (4 HOLES) DKHBA2f-04PF-1-000007K0 4 �5 38 12 � 15 22.0 42.5 0.875 242 DKHBA21-05PF-m-0000C/1K0 X44 14 17 25 0 48.5 0.875 334 DKH13A2i-06PF-1:(,-000007K0 6 � 50 15 _ 18 _ 28.0 54.5 0.875 414 DKH13A21-08PF-i7)-000007K0 8 60 17 20 `33 0 64.5 0.875 614 DKH13A2i-10PF-1Y,-000007K0 10 70 20 23 38.0 74.5 M 0.875 m 856 DKH13A21-12PF-in-000007K0 12 8 76 23 26 41.0 80.5 0.875 1161 DKH13A21`-14PF-1-::-000007K@ 14 80 27 30 43.0 84.5 0.875 1355 DKH13A2t-16PF-m-0002C7K2 16 8 86 8 30 33 46.0 X90.5 0,875 1689 DKHBA2`-18PF-::000007K0 yym20 18 92 33 36 49.0 96.5 d 0.875 1952 DKHBA2 f-20PF-m-000007K0 -----98 35 _d 38 52.0 _d 102µ5 _d 0:$75.2784 DKHBA2`-22PF- 000007K0 22 104 37 40 55.0 108.5 0.875 3163 DKHBA2f-24PF-m-0000071<0 24 110 40 8 43 58.0 114,5 0,875 3587 Connections sizes are nominal. Dimensions are in inches. Weights are in pounds and are approximate. s'rAIII P1i OIDtuc'r .i.ypicall Attelrluatinn r� carve Shell packed with 2" of fiberglass insulation to absorb high frequency sound waves and reduce outer surface temperature. • Bottom, top, and no mounting lug options (1). • Carbon steel or 304 stainless steel construction (rri). • Carbon steel housings coated with satin black paint rated to 1200°F • Connections: 125/150# ANSI bolt pattern flanges. COIIWIFIIOt.UICRAIBII IE oII • Side outlet (d) orientation. • Bottom inlet "E" dimensions (n). • Inlet size and connection type (i/) and outlet connection type (:+). • Dual inlet (1 /r ). • Flush mount inlet (j). • See II:::I Siilleinceirs II=Aairt III II...egeind (Ip. 6) dual inlet and "E" dimensions options require a part number from MIRATECH. CUSTOM 01P"i"110INS • Custom configurations, materials, connections, overall dimensions, etc. • Part numbers will be confirmed upon receipt of project design requirements, specifications, or order. 60 50 M ..a 40 ..7. Qp�} pQ 30 Cts ..x 20 10 63 125 250 500 1000 2000 4000 8000 Octave (Band Ceinlier IFrequency (II 14111R 41J1 1;111 1agP,. 2 ; � o. 1 16 "I' H1f�l " r>�atli '1 1;,� I @sL AvciILIC I' a!11 I)i'?:x1.> A, I Mals r, 010 14 1OE3 1 ?(' 3 1 &)C1�H�i��41) 3 14'1 i ��)rrriiar r c,h cc p.c,tainii I irili,'ali,x:elrt.cai La.t:erPaige 104 of 15i 102 1111 1 em Aw l Proposal Number: SDM-18-1239 Rev(2) Engine Allowable Back Pressure 14 inH2O Number of Engines 44 Exhaust Flow 25620 acfm (cfm) Number of Exhaust Outlets 2 Exhaust Temperature 892 F ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. Frequency Overall III II II I II n (Hz) 31.5 63 125 250 500 1 k 2k 4k 8k (dBA) Silencer Attenuation Range: 35-46 dBA Outlet Flow Component Description Flow Flow Rate Velocity Pressure Drop DKHBA2TX- DK -Series, Hospital Grade, Dual Full Flow 25620.0 acfm 167.2 ft/s 8.8 inH2O D16PF22PF-2-005WGWSQ Inlet, Carbon Steel Disk Silencer, 16" Pipe Flange End Inlet, 22" Pipe Flange Side (12:00) Outlet, Top Lugs Exit To Atmosphere Total Pressure Drop Full Flow 25620.0 acfm 167.2 ft/s 2.5 inH2O 11.2 inH2O Page 105 of 15;103 CONFIDENTIAL Page 2 of 2 Proposal Date: 2018-..- -- Q—LADDER NOT L 0• L K SHOWN THIS 337.5' 22'5 114591-4 DRAWING SEE — —' 30' 114591-6 1 14591 —6 & 7 114591-7 FALL PROTECTION DETAILS. J 45° 300° K / L F 292.5' 66.5' L ./D T__ _ 270° 1 — 90` A,B G 247.5' 112.5' L L 120° K J 225'135' ^ 210' — C H(16) 2" POUR FOAM K 202.5' 157.5' INSULATION W/ L 180' L STEEL OUTER WRAP E PLAN VIEW DESIGN DATA TOTAL CAPACITY — 33,000 GALLONS WORKING CAPACITY — 28,600 GALLONS TYPE — VERTICAL ASME PRESSURE VESSEL NO. REQ. — TWO MAX. ALLOW. WORKING PRES.— 80 PSIG @ 140 °F MAX ALLOW. EXTERNAL W.P. — — PSIG ® — 'F MIN. DESIGN METAL TEMP — —20°F @ 80 PSIG HYDROSTATIC TEST PRESSURE — 104 PSIG CORROSION ALLOWANCE— NONE POSTWELD HEAT TREATED — NONE RADIOGRAPHY — LONGITUDINAL SEAMS: FULL PER UW -11(b). CIRCUMFERENTIAL SEAMS: SPOT PER UW-11(a)(5)(b) HEADS — 0.3611" MIN., A" NOM. SA516 GR 70 ASME 2:1 ELLIPTICAL SHELL — J" NOM. SA516 GR 70 SKIRT — 3/8" BASE RING — J" THK. SEE DRAWING 114591-2 FOR DETAILS INT. FINISH — HIGHDROO LINER PLUS — INTERIOR COATING PER AWWA D-102 ICS 4 — 25 MILS CONSTRUCTION — BUTT WELD INSIDE & OUTSIDE ALL TANK FABRICATIONS TO BE IN ACCORDANCE WITH ASME SECTION VIII, DIVISION 1, 2019 EDITION, ALL SHELL, HEAD, FITTINGS AND MANWAYS TO BE WELDED TO BIGBEE STEEL WELD PROCEDURE PER DRAWING F11151 HIGHLAND TANK SERIAL # -- INSULATION WRAP DESIGN DATA PURPOSE — TO CONTAIN THE INSULATION ONLY; NOT A TRUE DOUBLE WALL TANK MATERIAL — ASTM A36 THICKNESS — 1/4 MIN. CONSTRUCTION — LAP WELD OUTSIDE ONLY INSULATION — 2" THICK POURFOAM TEST — NONE REQUIRED APPLY Y SPRAY FOAM NSL LA7M M THE 90T= HEAD EXT. FINISH — SP6 BLAST, THREE PART SYSTEM PER AWWA D-102 OCS 5. PRIMER: CHEMPRIME: 3001 (4-8 MILS DFT). INTERMEDIATE: CHEMPRIME 3001 (4-8 MILS DFT). TOP COAT: WHITE CHEMTANE 3300 (2-3 MILS D FT) NOTE: ALL RIGHTS RESERVED. THIS DRAWING MUST NOT BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF HIGHLAND TANK®. HIGHLAND TANK® SHALL BE RESPONSIBLE ONLY FOR ITEMS INDICATED ON THIS FABRICATION DRAWING UNLESS OTHERWISE NOTED. CUSTOMER IS RESPONSIBLE FOR VERIFYING CORRECTNESS OF SIZE AND LOCATION OF FFTNGS, ACCESSORIES, AND COATNGS SHOWN ON THIS DRAWING. TOUCH UP OF FINISHED PAINT IS REQUIRED BY INSTALLATION CONTRACTOR. TOUCH UP PAINT SHIPPED SHIPPING LUGS AS DRAWING 1 OF 7 114591-1 TANK LAYOUT 114591-2 LEGEND & BASE RING DETAIL. 114591-3 UPPER INLET DIFFUSER DETAIL. 114591-4 LOWER SUPPLY DIFFUSER DETAIL. 114591-5 SKIRT ACCESS & HOLD DOWN. 114591-6 HANDRAIL & LADDER DETAIL. 114591-7 FALL PROTECTION DETAILS. — ­­ 8/7Z201003 4-ummaliTalk— UNLESS NOTED, TOLERANCES ARE +/— 1' 33,000 GAL 150"0 ASN1E VESSEL CUSTOMER; VITAL_ FUELS PROJECT1CLOUD HQ MCC6 MANASSAS, VA QUOTE ND; 480509 CHK'D BY, 1/4° = 12° 7/zs/zo 003 1 1 4 5 9 1— 1 104 270° o- \ SAFETY SWING Q GATE c Aj/ 1p�I1IIµ N� 1 11 i II �i Ic r � I CUSTOMER TO SUPPLY \ _ _ 7::—: / LADDER LOCATIONS PLAN VIEW 90° coN �� 1» SQ, TUBING TYP. —IN W 0 F- C, TANK TDP SECTION VIEW A—A = SCALE: 21311=11-01, DRAWING 5 OF 7 114591-1 TANK LAYOUT 114591-2 LEGEND & BASE RING DETAIL. 114591-3 UPPER INLET DIFFUSER DETAIL. 11459 1 —4 LOWER SUPPLY DIFFUSER DETAIL. 114591-5 SKIRT ACCESS & HOLD DOWN. 114591-6 HANDRAIL & LADDER DETAIL. 114591-7 FALL PROTECTION DETAILS. —t 105 DESIGN DATA C4'. - TANK MATERIAL -MILD CARBON STEEL (2) }" ANCHOR FINISH - SAFETY YELLOW BYLTS OTHERSPLIED LEGEND C D C 11 A ANGLE 2" x 2" x q" (SIDE RAILS) i B 1"0 ROUND BAR (LADDER RUNGS) � � A SAFETYANGLE 3 x 3 x x 1 ANCHOR BOLT SWING C CLIPS) SEE DETAIL C GATE z4° D F.B.-2" x ON APPROX. 8' SPACING (TANK 15" MIN. TO LADDER 20" MAX. 17" 27" PLAN VIEW ANODIZED ALUMINUM CLIMBING RAIL - FRENCHCREEK PRODUCTION ITEM# 1 -1100 -AR LARGE SAFETY HARNESS (240-28D POUNDS) FALL PROTECTION DETACHABLE SLEEVE BY OTHERS ONTHE AWING }' ANCHOR "S SUPPLIED )THERS CLIMBING TROLLEY FRENCHCREEK PRODUCTION ITEM#2-120OA-AT 7_» 8 MIS 100 SIN 9» 116 "�_u J 1�» L 13 DETAIL C SCALE: 1"=l' -O" DRAWING MUST NOT BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF HIGHLAND TANK®. HIGHLAND TANK® SHALL BE RESPONSIBLE ONLY FOR ITEMS INDICATED ON THIS FABRICATION DRAWING UNLESS OTHERWISE NOTED. CUSTOMER 15 RESPONSIBLE FOR VERIFYING CORRECTNESS OF SIZE AND LOCATION OF FDTINGS, ACCESSORIES, AND COATINGS SHOWN ON THIS DRAWING. TOUCH UP OF FINISHED PAINT IS REQUIRED BY INSTALLATION CONTRACTOR. TOUCH UP PAINT SHIPPED SHIPPING LUGS AS DRAWING 7 OF 7 114591-1 TANK LAYOUT 114591-2 LEGEND & BASE RING DETAIL. 114591-3 UPPER INLET DIFFUSER DETAIL. 114591-4 LOWER SUPPLY DIFFUSER DETAIL. 114591-5 SKIRT ACCESS & HOLD DOWN. 114591-6 HANDRAIL & LADDER DETAIL. 1 14591-7 FALL PROTECTION DETAILS. uMEMO- UNLESS NOTED, TOLERANCES ARE +/- 1" FALL PROTECTION CUSTOMER: VITAL FUELS PROJECT1CLOUD HQ MCC6 MANASSAS, VA QUOTE NO; 480509 CHI -D HY' 3/s° = 12° 7/29/20 003 1 1 45 9 1 — 7 106 Cloud HQ LC2 April 8, 2019 Performance Data - Ascend(TM) Air -Cooled Chiller Model ACR Tags All Units All Units Mechanical Mode Free -Cooling Mode Refrigeration capacity tons 362.00 362.0 @ 35.0T Total power kW 332.1 Compressor power kW 301.6 Cooling efficient EER Btu/W-h 13.081 IPLV.IP (EER (Btu/W-h)) 21.978 NPLV.IP EER Btu/W-h 26.442 Leaving fluid evap (F) 65.00 65.00 Entering fluid evap (F) 81.00 81.00 Flow evap (gpm) 571.59 571.59 Fluid pressure drop evap (ft H2O) 29.93 29.93 FREE -COOLING Coil pressure drop ft H2O 0.00 14.50 PP Components/Piping Pressure drop ft H2O 8.00 14.57 Chiller/FREE-COOLING pressure drop 37.93 (ft H2O) 59.00 System pressure drop ft H2O 77.0 77.0 Total pressure drop (ft H2O) 115.00 136.00 Evap fouling factor(hr-sq ft -de F/ Btu 0.000100 Evap Fluid (type) Propylene Glycol Propylene Glycol Evap fluid concentration % 30.00 30.00 Evap fluid freeze point F 9.19 9.19 Min flow evap pm 366.20 Fluid pressure drop min flow evap ft H2O 11.40 Max flow evap m 866.00 Fluid pressure drop max flow evap ft H2O 69.42 Saturated evap tem - ckt 1 F 62.37 Saturated evap temp - ckt 2 (F) 63.34 Ambient air tem F 103.80 35.0 Saturated cond tem - ckt 1 F 142.76 Saturated cond temp - ckt 2 F 143.30 Elevation (ft) 295.00 RLA - comp A - AFD input A 200.00 RLA - comp B - AFD input A 200.00 Number of condenser fans (Each) 16.00 RLA - condenser fan each A 3.10 Fan power kW 30.1 Single point power MCA (A) 559.61 559.61 Single point power MOP (A) 700.00 700.00 Short circuit current rating A 65000.00 65000.00 Refri HFC -134a - ckt 1 Ib 325.0 Refri HFC -134a - ckt 2 Ib 325.0 Oil charge - ckt 1 al 4.00 Oil charge - ckt 2 al 4.00 Drive cooling charge - ckt 1 al 1.41 Drive cooling charge - ckt 2 al 1.95 Shipping weight (lb) Im Operating weight(lb) NRINA Length (in) 495.900 495.900 Width (in) 99.400 99.400 Height (in) 102.400 102.400 Run part load sound Yes A-wei hted sound ower dBA A-wei hted 75% sound ower dBA A -weighted 50% sound power (dBA) 102 98 95 Euvue to olper alin0 standards., allll dhilllleirs meirate at 75% or Mess. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 of 93 Others 107 Xerxes Underground Urea Storage Tank — Brochure & Drawing 108 a zciiiiii. company IINiies6l Exhaust IIF I t iiii t IIS IIS The best choice for an emerging need - DEF Changing regulations and new diesel engine technology are creating demand for a new product, Diesel Exhaust Fluid (DEF) which is a formulation of 32.5 percent urea and demineralized water. The urea DEF is stored in the on -board containers of newer diesel engine vehicles and injected into the exhaust stream. It is designed to be used with the Selective Catalytic Re- duction (SCR) emission systems that are found on most new diesel -powered vehicles, as a step toward reducing the nitrogen oxide (NOx) exhaust from these vehicles. IDernaind andUse The current demand for DEF in the United States is relatively small, but is growing significantly as more new vehicles equipped with SCR emission systems enter the market. As overall demand continues to grow, fuel retailers and fleet vehicle operators have increasingly been looking to bulk storage options for their facilities. Large truck stop retailers have actively been adding fiberglass underground bulk storage tanks, enabling them to dispense the product at their fuel islands. Addi- tionally, private, commercial and government fleets, many of whom maintain fueling operations, may find bulk storage of DEF a necessity in the future. Future demand will also be driven by regulations that are not yet fully implemented which will impact sectors of the diesel market other than passenger vehicles, such as rail, farm, marine and construction. Consider the f llllll thin featuires and Ibeurnefiiits of un 'eir it uind IlbLAllllk st ura e: Facility IC Desigin — Underground storage provides greater site design flexibility and doesn't require setting aside valuable property, as with the use of large aboveground storage containers located on or near diesel fueling islands. Potential accidents with vehicle collisions can be avoided and site aesthetics are greatly improved by placing bulk storage below grade. ll"bimpeir tuire Cointiroll — No need for special equipment and the annual costs involved in maintaining product temperature inside the tank, which are necessary with aboveground storage containers. Urea DEF will freeze when stored below 12°F. As storage temperatures rise, its shelf life is reduced and its quality deteriorates when exposed to temperatures exceeding 777 for extended durations. An underground tank provides a simple and effective way to maintain proper DEF storage temperatures. Future Use Flexibility — Installing a UL -listed underground tank gives facility owners the option to convert their bulk DEF storage to some other use in the future, such as diesel fuel or a different grade of gasoline. An aboveground unit with a polyethylene tank doesn't provide this valuable option. making a 11asting difference" 109 1Ihne Xeirxes Solution Recognizing a growing demand for underground storage of DEF, Xerxes began developing a product in early 2010, based in part on some of the unique requirements that must be considered in designing DEF storage and handling equipment. Many of these unique requirements have been addressed in the Petroleum Equipment Institute's new recommended practice PEI/ RP1100-10. Xerxes was the only underground tank manufacturer actively involved in the development of this important equipment standard. With well over 500 DEF tanks in service throughout North America today, it's clear that customers have confidence in the Xerxes solution. on iii ' it the follllllo iiiing Xeirxes featuires and I iia - iiit : IFxternsiive "Testiirng —The ISO standard 22241-1 is widely accepted as establishing industry requirements for DEF purity and material compatibility. Based on this standard, carbon steels are not recommended for contact with DEF, while stainless steel 304 and 316 are examples of recommended materials. Fiberglass reinforced plastics (FRP) and certain other materials are not identified as either "recommended" or "not recommended," although the standard allows for manufacturers of equipment to test other materials beyond those identified in the document. As part of product development, Xerxes initiated extensive testing involving independent third -party testing laboratories as well as key material suppliers, together with technical consultations with the leading DEF product suppliers. The results on multiple levels confirmed that Xerxes tanks are suitable for storage of urea DEF when specifically designed and manufactured for that intended use. uulpeiriioir IC esii in — Unlike carbon steel tanks, a Xerxes fiberglass tank does not require special coatings or linings to protect the purity of the DEF product. Xerxes uses stainless steel fittings, manway covers and striker plates. A UL -label is attached to all tanks that meet listing criteria. Each tank interior is thoroughly cleaned and then sealed to prevent contamination during shipping and installation. Finally, the product is backed by a 30 -year warranty. Xerxes 1DIE F Tanks: • Fabricated with materials specifically tested for DEF storage • Available in single-, double-wall, and multicompartment models • Available in UL -listed models • Offer a 30 -year limited warranty • Use only stainless steel fittings, manway covers and striker plates • Available throughout North America uuu uuu 0 I ' a iiiil company 7901 Xerxes Avenue52-887-1890 www.xerxes.com 55431 usa making a Ilastingl difference" © 2012 Xerxes Corporation xdefp10/12ih 110 o- �p b Z a o o L{7 � CO o V, O o CL oz d o aw .z E "'l t O o a Cp z z Wow II z . a d� U a a inO � x - w w a z 0 w oW 0 S 3 c n o n -1/)wo C o O � s am sm am e g a a o aiw W p n� o�x - >o� Y w U Q w 0 o 3 m a� Q CL Z Q W N ae ¢ Q w W Z I V1S� W QOVI U K z } a MZ I w ¢ x z W 0 00 ¢ I z <M W w m w 0 w MAY Oz Q m w U w QQ VO—Q0 V1� mw I I I — x w N N M w o 0 O O O z a o 00 a } N O ¢ m N a\ w a„ M O z \ V1 N w w m N � K N ¢ a o fn U K Y O ti w m m c� \ a M u7 in V1 6 V O 6 N Z M x a N Z x a w � o 3 > to ¢ � � o z (n w w Q � V1 Z w Z U � O o aQ V z z w z ¢ o ¢ O w U U x U O X O x ¢ Z w } ± ¢U O U > Z M m m d m Q Z d N V w O ¢ ¢ z a U a Y) a o 0 0 z w O D] N O d +a M 7 N x } d w 00�0�111 a zcIIIIII. company �Taink AiinchoiiHhing tII An engineered solution Xerxes recognizes that the components of a tank anchoring system can be critical to a reliable, long-term tank installation. A large percentage of today's underground tank installations are anchored, whether site conditions mandate it or not. Use of inferior components, such as improperly designed or undersized concrete deadmen, can lead to disastrous results. As a solution, we designed and began supplying each of the components essential to proper tank anchoring, prefabricated deadmen, galvanized turnbuckles and extruded fiberglass hold-down straps. Providing a safe, dependable anchoring solution is not our only objective. The Xerxes anchoring package is also designed to provide installers with a quick, easy to install package of components that expedites the overall installation. The Xerxes tank anchoring system is yet another example of product innovations that Xerxes has been offering customers for more than three decades. Considerthe follllllo iiirmg f atur s aind in - iiits IFllexiilblle If;)siire — Xerxes prefabricated deadmen were engineered with ease of shipping and installation in mind. With their unique and patented design, which incorporates adjustable galvanized steel anchor points, installers can properly align each anchor point and hold-down strap after the tank and deadmen have been set in place. Ain IFirn iiirne irLid Il11iroduct—Tank installers and owners can have the confidence that prefabricated deadmen, an often overlooked yet critical component of an anchored tank installation, have been properly engineered and sized for each tank. Xerxes precast deadmen are fabricated to meet American Concrete Institute (ACI) design standards, which establishes such things as proper steel reinforcement, concrete psi specifications and adequate cure time. I1lrarns1p irtatiioirn — An additional feature of Xerxes deadmen is that their geometry and dimensions allow them, in most cases, to be placed on the same shipping trailer as the tank. For installers, this means that the components of the anchoring system arrive with the tank, avoiding the potential for jobsite delays. A C irn Ipll t syst irren — Combined, Xerxes supplied fiberglass hold-down straps, galvanized turnbuckles and prefabricated deadmen provide a complete anchoring package. With each component specifically designed and supplied by Xerxes, facility owners have the added peace -of -mind that in addition to having installed the industries' finest storage tank, they have also installed a reliable anchoring system. making a 11asting difference" 112 .................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. Ii. eadlrnein fo1r '...-, '...- & W.-Diairneteir Taink Installations Norninal vvidth x depth galvanized anchor point 12' 12" x 12" 11800 16' 12" x 12" 2,400 18' 12" x 12" 4,000 prig 30' 18" x 8 3/4" 5,000 concrete #5 rebar galvanized anchor points ` (Qty. 4) alignment slot alignment slot ®.® 4. 4 . 15" 4. d 4nn. IC ea d I e In "for 10'...- a In d II fi rn ii ted 12'...- IGS fi a Iran ete Ir ""Iia In Ik II Inst, 11 11 a t ii o iris galvanized anchor points alignment slot /—L alignment slot 11 u n i galvanized anchor point 4,000 prig concrete /#7 rebar ` (Qty. 2) \y #6 rebar ..o (Qty. 2) . .6. Product Specifications �D e a d irn e in 'f o it 4".... M6 ".... a in d 8 "....11...) II a IIS d "'rL e it T"a in Ik s Nominal length Norninal vvidth x depth ApproximatE' weight (Ibs.) 12' 12" x 12" 11800 16' 12" x 12" 2,400 18' 12" x 12" 2,700 Il. eadimen for 10..... airnd 1 .....Il. iiaimer.eir...I...ainks Nominal length Nominal vvidth x depth Approximate weight (lbs.) 14' 18" x 8 3/4" 1,900 22' 18" x 8 3/4" 3,000 30' 18" x 8 3/4" 5,000 R.Arrlbu ckIIes Jaw -to -Jaw Style 6' Diameter ranks 3/4" x 9" (17" closed, expanding to 26") 8' Diameter ranks 3/4" x 12" (20" closed, expanding to 32") 10' and 12' Diameter ranks 3/4" x 18" (26" closed, expanding to 44") Geineirall Notes 1. Deadmen requirements may vary with tanks 25,000 gallons or larger, and/or based on the number of containment sumps, access risers and burial depth. 2. Consult the Xerxes Installation Manual and Operating Guidelines or your Xerxes sales representative for more information. : S iiia a IIIA company 7901 Xerxes Avenue52-887-1890 www.xerxMinneapolis, 55431 USA making a lasting l difference"rencdifference" © 2012 Xerxes Corporation xas10/12ir 113 Attached Collar/Riser — Cut Sheets 114 m Q z O 0 w Of LLI F - z Ld U U) a 0 z Lal a- 0 w U U a G go qdW O z 115 0 Y Hz00 zza 00W a I o Z� O O W } Q O UM C3 O F ¢ g 0 m V) N U W0a Of L, J o cr LLI w xW u' U O Z F � — a m L LI � o fr F- oc W- ------------------- -------- = V) r Lr Ln O V) , — W ' U ' _ U to u! Q Ln of ` aw m ----------- ----------------- = W t9 r-- Q ' ir0 -j Q LaJ 0 LLc czI >- of _ — m LaJ J i LL m a. , C3— — J U) ` C3 a LLi o W M x w= Z) x — p i LLI LL Q Wv x 115 Hz00 z 00W a I o O O VI W UM V) ¢ ¢ g a z OU U W0a ❑ xW 00 F � � � o 115 Deadmen — Cut Sheet 116 r N a ni ro O 3 G} 3,000 r y ro --q � n cn 4, 000 �- +- N � o � m `n rn 5, ©no a a ro r� fl 6,000 ro � k} a, 000 CO. CO sw 10,000 ro ro i- -1 1P, 000 co m -t- j 15,000 y or, { c � x x � 1 y [� C7 L5 k7 k7 O b D D N m m m m --i r- 7. 2� A vi F A H L b b N Z Z 'C4 s-- � r/1 3 Q x � ra ru ry z 70 r S U N X X X P T D O 0J 4+ rU l ❑ ❑ i ?Ll zm 117 Hold Down Straps — Cut Sheet 118 c, m a a H D � � a tj u � m fl p Cl m Vl frl "" N 0 4F m C:, -u-< o w m I— D, m m r4 m M P- m n F s -a IU C] w O, q g 3 1 1 1 1 1 r z n a n 31 z z z;�zzzc rti }i 7� h R T 7u zz W -P � P W CI G7 Ll Gi G7 .-4 H spa H D m m m L M mmmmmc, "Ll Vi Vi Lh Vl {h C C � Llr m m C d m cy M r- M r u 2 �° z r C M T m G L D S7 n m d e I N d2 o z0 x D � y� o � vi VOD 119 NQ {q4�� � h! m fU C7 U] N bi 'meq I I I I~ 1 � � m --1 r 119 -0 I I I I OHM, P h. M'6ammIlly 1NpGM1 Village of Mount Prospect Community Development Department 50 S. Emerson Street Mount Prospect, Illinois 60056 ,a/ Phone: (847) 818-5328 Zoning Request Application I: Subject Property Address(es): 1200 E. Algonquin Road & 1200 Dempster Street, Mount Prospect, IL Zoning District(s): I-1 Property Area (Sq.Ft. and/or Acreage): 49.72 acres Parcel Index Number(s) (PIN(s): 08-23-100-018-0000 and 08-23-200-052-0000 ❑X Conditional Use: For Planned Unit Development for Data Center Campus ❑ Variation(s): To ❑ Zoning Map Amendment: Rezone From To ❑X Zoning Text Amendment: Section(s) See Proposed Zoning Text Amendment Attached ❑ Other: III. Summary of Proposal (use separate sheet if necessary) See Attached Project Narrative IV. Applicant all correspondence will be sent to theapplicant) Name: CloudHQ LLC Corporation: Address: 1212 New York Avenue, NW, Suite 1000 City, State, ZIP Code: Washington, DC 20005 Phone: 571-643-6718 (Pete Hohm. VP: Development) Email: _pllq_clloudhq„conn Interest in Property: Contract Purchaser (e.g. owner, buyer, developer, lessee, architect, etc...) 4849-5573-0424.v7 122 Pro perty Owner Check if Same as Applicant Name: Nathan Lopp, Vice President Corporate Real Estate Corporation: United Airlines, Inc.____.__-_--___. _a,____ Address: nc----------------- Address: .---233 South Wacker Drive, HDQOU -------- - ------- City, State, ZIP Code: - Chicago, Illinois 60606 Phone: Email: In consideration of the information contained in this petition as well as all supporting documentation, it is requested that approval be given to this request. The applicant is the contract purchaser of the property. The applicant and the owner of the property grant employees of the Village of Mount Prospect and their agents permission to enter on the property during reasonable hours for visual inspection of the subject property. I hereby affirm that all information provided herein and in all materials submitted in association with this application are true and accurate tote best of mZ knowledge. Applicant: -0000 - - Z Date: (Signature) ceo (Print or Type Name) If applicant is not property owner: I hereby designate the applicant to apply for the zoning request(s) described in this application and the associated supporting material. Property Owner: (Signature) (Print or Type Name) 4849-5573-0424.v7 2 -Property Owner0 Check if Same as Applicant Name : United Airlines, Inc. -----_' Address: 233 South Wacker Drive, HDQOU CUx, State, ZIP Code: Chicago, Illinois 60606 Phone: Email: Nathan. LopPOWnited.com are true and accurate to the best of my knowledge. (Print or Type Name) Ifapplicant ionot property owner: | hereby designate the applicant to apply for the zoning request(s) described in this application and the associated supporting material. Property Owner: Date: September 1, 2021 Nathan Lopp (Print or Type Name) 2 �µ ,'" t,H c y"ii DU PAGE COUNTY OF 866* STATE OF ILLINOIS 1, Nathan Lopp under oath, state that i am (print name) ❑ the sole owner of the property Q an owner of the property ® an authorized officer for the owner of the property commonly described as 1200 E. AI , IL (property address and PIN) 08-23-100-018-0000 and 08-23-200-052-0000 and that such property is owned by United Airlines, Inc. as of this date. (print name) Signature Subscribed and sworn to before me this 1 st day of September 12021 ZZ '2a&7Z"'i Notary Public OFFICIAL SEAL LAURAA. ASIVIUSSEN NOTARY PUBLIC, STATE OF ILLINOIS My Commission Expires 08-08-2023 125 Ali-c# x:1114 029_ Fwe� �� �,ms , 00 RHSP FEE:$9,00 RPRF FEE: 61.00 This Instrument Prepared by KAREN A. YAR}3ROLIGH and After Recording Return to: Douglas E. Wanrbach COOK COUNTY CLERK Burke, Warren, MacKay & Serritella, P.C. DATE; 0612312021 01:36 PM PG: 1 OF 6 330 N. Wabash Ave., 21" Floor Chicago, IL 60611 MEMORANDUM OF PURCHASE AND SALE AGREEMENT THIS MEMORANDUM OF PURCHASE AND SALE AGREEMENT (this "Memorandum") is made and entered into as of the 17"' day of June, 2021 by and between UNITED AIRLINES, INC., a Delaware corporation ("Seller") and CLOUDHQ LLC, a Delaware limited liability company ("Purchaser"). RECITALS A. Seller is the owner of certain real property located in the Village of Mt. Prospect, County of Cook, Illinois, described on Exhibit A attached hereto and made a part hereof the "Property"). B. Seller and Purchaser have entered into that certain Purchase and Sale Agreement dated as of June 17, 2021, (tile "Purchase Agreement") pursuant to which Seller has agreed to sell the Property to Purchaser upon the terms and conditions set forth in the Purchase Agreement. C. Seller and Purchaser desire to set forth certain terms and provisions contained in the Agreement in this Memorandum for recording purposes. NOW, THEREFORE, for and in consideration of the mutual covenants, agreements and conditions set forth in the Purchase Agreement, Seller and Purchaser do hereby covenant, promise and agree as follows: 1. Definitions. Capitalized terms used herein which are not otherwise defined herein shall have the respective meanings ascribed to them in the Purchase Agreement. 2. Purchase. Pursuant to the Purchase Agreement, Seller has agreed to sell the Property to Purchaser upon the terms and conditions set forth in the Purchase Agreement. 3. Term. This Memorandum shall expire and be of no further force and effect on the earlier of (i) the date a release and termination of this Memorandum is recorded in the Cook County Recorder of Deeds and (ii) January 4, 2022. 4. Counterparts. "Phis Memorandum may be signed in counterparts. [Signature Page Follows] ACTIVE 269413997v.2 IN WITNESS WHEREOF, Seller and Purchaser have executed this Memorandum as of the date first above written. SELLER: UNITED AIRLINES, INC., a Delaware corporation By: Name: Nathan Lopp Its: Vice President Corporate Real Estate PURCHASER: CLOUDHQ LLC, a Delaware limited liability company By:_ Name: Its: ti IN WITNESS WHEREOF, Seller and Purchaser have executed this Memorandum as of the date first above written. UNITED AIRLINES, INC. a Delaware corporation By: Name: Nathan Lopp Its: Vice President Corporate Real Estate PURCHASER: CLOUDHQ LLC, a DZa e,imi e liability company By: Name: Keith P. Harney Its: Chief Operating Officer/Authorized Signatory 00 04 T- STATEOF ILLN01-5) )SS COtTNTY Given tinder my hand and official seat, this Alidayof 2021. Commission expiresA"201,3- OFFICIAL SEAL LAURA A. ASMUSSEN KI 6*L N4oLtary Public�� 0 M T ACKNOWLEDGMENT DISTRICT ) OF COLUMBIA ) SS I, the undersigned, a Notary public in and for the District of Columbia, DO HEREBY CERTIFY that Keith P. Harney personally known to me to be the Chief Operating Officer of C1oudHQ LLC, a Delaware limited liability company, and personally known to me to be the same person whose name is subscribed to the foregoing instrument, appeared before me this day in person and acknowledged that as such Chief Operating Officer he signed and delivered the said instrument as his free and voluntary act, and as the free and voluntary act and deed of said company, for the uses and purposes therein set forth. Given under my hand and official seal, this CC day of June, 2021. Commission expires , 20 Notary Public �tY 1'() � :o 1 `'Y [End of Signatures.] Uo' SSI' N ;? 2025 rn 4 T M T FXI-IIRIT Parcel 1: Lot 1 in Friedrich Busse, Jr. Division of Land in Section 23, Township 41 North, Range 11 East of the Third Principal Meridian, according to the plat thereof recorded February 20, 1911 as Document No. 4709799, except (A) that part of said Lot 1 taken for highways, and (B) that part falling in Blue Sky Subdivision according to the plat thereof recorded June 5, 2014 as Document No. 1415616048, in Cook County, Illinois. Parcel 2: The West 363.00 feet of Lot 2 in Linneman's Division of part of the Northeast 1/4 of Section 23, Township 41 North, Range 11 East of the Third Principal Meridian, and part of the Southeast 1/4 of Section 14, Township 41 North, Range 11 East of the Third Principal Meridian, according to the plat thereof recorded September 10, 1953 as Document No. 15716544, in Cook County, Illinois. Parcel 3: The North 120.00 feet of the West 363.00 feet of Lot 3 in Linneman's Division of part of the Northeast 1/4 of Section 23, Township 41 North, Range 11 East of the Third Principal Meridian, and part of the Southeast 1/4 of Section 14, Township 41 North, Range 11 East of the Third Principal Meridian, according to the plat thereof recorded September 10, 1953 as Document No. 15716544, in Cook County, Illinois. 1200 E Algonquin Rd, Mt. Prospect, IL PIN: 08-23-100-018 Affects Parcel 1 1200 Dempster St, Mt. Prospect, IL 08-23-200-052 Affects Parcels 2 and 3 /_10r_«97►ailMI10MI=1Ll19;101 iI104=1ILlRIIII X1ZM Commitment Number: Issued By: 0 Flidefity National Title' FCH12000834LI Tw,"urance coatataasty' NOTICE IMPORTANT - READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY'S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I -Requirements; Schedule B, Part II -Exceptions; and the Commitment Conditions, Fidelity National Title Insurance Company, a Florida corporation (the "Company"), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I -Requirements have not been met within one hundred eighty (180) days after the Commitment Date, this Commitment terminates and the Company's liability and obligation end. Countersigned By: Peter R. Petersen Authorized Officer or Agent Fidelity National Title Insurance Company By: A. Hi" I,— Attest: Randy Quirk, President Marjorie Nemzura, Secretary This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN IAI The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. M ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 1 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 132 FIDELITY NATIONAL TITLE INSURANCE COMPANY Transaction Identification Data for reference only.- ORIGINATING nly. COMMITMENT NO. FCH12000834LI ORIGINATING OFFICE: FOR SETTLEMENT INQUIRIES, CONTACT: Fidelity National Title Insurance Company BridgeTrust Title 20 N Clark, Ste 220 1320 Old Chain Bridge Road, Suite 210 Chicago, IL 60602 Mc Lean, VA 22101 Main Phone: (312)621-5050 Email: ilcommercial@fnf.com Order Number: FCH12000834LI Property Ref.: 1200 Dempster St, Mt. Prospect, IL 1200 E Algonquin Rd, Mt. Prospect, IL SCHEDULE A 1. Commitment Date: July 16, 2021 2. Policy to be issued: (a) ALTA Owner's Policy 2006 Proposed Insured: CloudHQ, LLC, a Delaware limited liability company Proposed Policy Amount: $54,000,000.00 (b) ALTA Loan Policy 2006 Proposed Insured: Lender with a contractual obligation under a loan agreement with the Proposed Insured for an Owner's Policy, its successors and/or assigns as their respective interests may appear. Proposed Policy Amount: $10,000.00 3. The estate or interest in the Land described or referred to in this Commitment is: Fee Simple 4. The Title is, at the Commitment Date, vested in: United Airlines, Inc., a Delaware corporation, successor by merger and change of name to United Air Lines, Inc., a Delaware corporation 5. The Land is described as follows: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF END OF SCHEDULE A This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. AM F RICAN Copyright American Land Title Association. All rights reserved. FAN„ TITLE The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 2 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI EXHIBIT "A" Legal Description Parcel 1: Lot 1 in Friedrich Busse, Jr. Division of Land in Section 23, Township 41 North, Range 11, East of the Third Principal Meridian, according to the plat thereof recorded February 20, 1911 as Document No. 4709799, except (A) that part of said Lot 1 taken for highways, and (B) that part falling in Blue Sky Subdivision according to the plat thereof recorded June 5, 2014 as Document No. 1415616048, in Cook County, Illinois. Parcel 2: The West 363.00 feet of Lot 2 in Linneman's Division of part of the Northeast 1/4 of Section 23, Township 41 North, Range 11 East of the Third Principal Meridian, and part of the Southeast 1/4 of Section 14, Township 41 North, Range 11 East of the Third Principal Meridian, according to the plat thereof recorded September 10, 1953 as Document No. 15716544, in Cook County, Illinois. Parcel 3: The North 120.00 feet of the West 363.00 feet of Lot 3 in Linneman's Division of part of the Northeast 1/4 of Section 23, Township 41 North, Range 11 East of the Third Principal Meridian, and part of the Southeast 1/4 of Section 14, Township 41 North, Range 11 East of the Third Principal Meridian, according to the plat thereof recorded September 10, 1953 as Document No. 15716544, in Cook County, Illinois. This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy, the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. AM F RICAN Copyright American Land Title Association. All rights reserved. FAN„ TITLE -11' , — The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. M ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 3 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 134 FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. FCH12000834LI SCHEDULE B, PART I REQUIREMENTS All of the following Requirements must be met: 1. The Proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. 2. Pay the agreed amount for the estate or interest to be insured. 3. Pay the premiums, fees, and charges for the Policy to the Company. 4. Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. 5. Notice: Please be aware that due to the conflict between federal and state laws concerning the cultivation, distribution, manufacture or sale of marijuana, the Company is not able to close or insure any transaction involving Land that is associated with these activities. 6. Be advised that the "good funds" of the title insurance act (215 ILCS 155/26) became effective 1-1-2010. This act places limitations upon the settlement agent's ability to accept certain types of deposits into escrow. Please contact your local Fidelity Title office regarding the application of this new law to your transaction. 7. For each policy to be issued as identified in Schedule A, Item 2; the Company shall not be liable under this commitment until it receives a designation for a Proposed Insured, acceptable to the Company. As provided in Commitment Condition 4, the Company may amend this commitment to add, among other things, additional exceptions or requirements after the designation of the Proposed Insured. 8. Payment of real estate taxes affecting the land that may be due or payable prior to closing (or as may be required by a lender to be insured). Schedule B tax exception will be amended accordingly based on a later date search and payment as noted herein. For all mortgages and liens referenced below, we should be furnished with proper payoff figures, authorizations, funds and documents sufficient to pay off and release said liens at or prior to closing. 10. INTENTIONALLY DELETED. 11. INTENTIONALLY DELETED. 12. Effective June 1, 2009, pursuant to Public Act 95-988, satisfactory evidence of identification must be presented for the notarization of any and all documents notarized by an Illinois notary public. Satisfactory identification documents are documents that are valid at the time of the notarial act; are issued by a state or federal government agency; bear the photographic image of the individual's face; and bear the individual's signature. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 4 IL -FT -FILL -03000.233208 -SPS -1 -21 -FCH12000834LI 135 FIDELITY NATIONAL TITLE INSURANCE COMPANY SCHEDULE B, PART I REQUIREMENTS (continued) COMMITMENT NO. FCH12000834LI 13. The Proposed Policy Amount(s) must be increased to the full value of the estate or interest being insured, and any additional premium must be paid at that time. An Owner's Policy should reflect the purchase price or full value of the Land. A Loan Policy should reflect the loan amount or value of the property as collateral. Proposed Policy Amount(s) will be revised and premiums charged consistent therewith when the final amounts are approved. 14. We should be furnished a properly executed ALTA statement and, unless the land insured is a condominium unit, a survey if available. Matters disclosed by the above documentation will be shown specifically 15. The Company should be furnished a statement that there is no property manager employed to manage the Land, or, in the alternative, a final lien waiver from any such property manager. 16. If work has been performed on the Land within the last six months which may subject the Land to liens under the mechanics lien laws, the Company should be furnished satisfactory evidence that those who have performed such work have been fully paid and have waived their rights to a lien. If evidence is not provided or is unsatisfactory, this commitment/policy will be subject to the following exception: Any lien, or right to a lien, for services, labor or material, heretofore or hereafter furnished, imposed by law, and not shown by the Public Records. The Company reserves the right to add additional items or make further requirements after review of the requested documentation. NOTE: "Work" refers to all lienable work contracted for or performed, to include, without limitation, improvements by or for tenants; architectural, structural engineering, civil engineering, soil testing, environmental evaluation and abatement services and interior design services; repairs, renovations, remodeling and demolition. 17. Note: The land lies within a county which is subject to the Predatory Lending Database Act (765 ILCS 77/70 et seq. as amended). A Certificate of Compliance with the act or a Certificate of Exemption therefrom must be obtained at time of closing in order for the Company to record any insured mortgage. If the closing is not conducted by the company, a certificate of compliance or a certificate of exemption must be attached to any mortgage to be recorded. Note: for Cook, Kane, Will and Peoria counties, the act applies to mortgages recorded on or after July 1, 2010. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 5 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 136 FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. FCH12000834LI SCHEDULE B, PART I REQUIREMENTS (continued) 18. Note for additional information: the County Recorder requires that any documents presented for recording contain the following information: A. The name and address of the party who prepared the document; B. The name and address of the party to whom the document should be mailed after recording; C. All permanent real estate tax index numbers of any property legally described in the document; D. The address of any property legally described in the document; E. All deeds should contain the address of the grantee and should also note the name and address of the party to whom the tax bills should be sent. F. Any deeds conveying unsubdivided land, or, portions of subdivided and, may need to be accompanied by a properly executed "plat act affidavit." In addition, please note that the certain municipalities located in the County have enacted transfer tax ordinances. To record a conveyance of land located in these municipalities, the requirements of the transfer tax ordinances must be met. A conveyance of property in these cities may need to have the appropriate transfer tax stamps affixed before it can be recorded. This exception will not appear on the policy when issued. 19. Municipal Real Estate Transfer Tax Stamps (or proof of exemption) must accompany any conveyance and certain other transfers or property located in Mount Prospect. Please contact said municipality prior to closing for its specific requirements, which may include the payment of fees, an inspection or other approvals. 20. The Company will require the following documents for review prior to the issuance of any title insurance predicated upon a conveyance or encumbrance by the corporation named below: Name of Corporation: United Airlines, Inc., a corporation of Delaware (a) A Copy of the corporation By-laws and Articles of Incorporation (b) An original or certified copy of a resolution authorizing the transaction contemplated herein (c) If the Articles and/or By-laws require approval by a `parent' organization, a copy of the Articles and By-laws of the parent (d) A current dated certificate of good standing from the proper governmental authority of the state in which the entity was created and from the Illinois Secretary of State The Company reserves the right to add additional items or make further requirements after review of the requested documentation. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 6 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 137 FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. FCH12000834LI SCHEDULE B, PART I REQUIREMENTS (continued) 21. The Company must be provided the following documentation regarding the limited liability company named herein, and this commitment remains subject to amendment for the addition of Requirements and/or Exceptions as may be deemed necessary upon its review of same: Limited Liability Company: CloudHQ, LLC, a Delaware limited liability company a) A copy of its operating agreement, if any, and any and all amendments, supplements and/or modifications thereto, certified by the appropriate manager(s) or member(s); b) A copy of its Articles of Organization and all amendments thereto with the appropriate filing stamps; c) A full and complete list of current members certified by the appropriate manager(s) or member(s); d) A current dated certificate of good standing from the proper governmental authority of the state in which the entity was created and from the Illinois Secretary of State; e) If fewer than all members or managers will be executing the closing documents, a resolution approving the contemplated transaction and granting authority to those managers or members who are signing. Note: In the event of a sale of all or substantially all of the assets of the limited liability company, or of a sale of company assets to a member or manager, we should be furnished a copy of a resolution authorizing the transaction adopted by all of the members of said limited liability company. NOTE: As of 8/2/21 said entity is not authorized to do business in Illinois. This must be accomplished prior to closing the anticipated transaction. 22. Note for Information regarding endorsement requests: All endorsements requests should be made prior to closing to allow ample time for the Company to examine required documentation. 23. Lien in favor of the Village of Mount Prospect to which the Land will become subject in the event that a deed of conveyance thereof or an assignment of the beneficial interest therein is recorded without having affixed thereto the revenue stamps required by Ordinance recorded September 28, 1987, as Document No. 87527187. 24. The recording of any deed, other instrument of conveyance of the Land, or assignment of the beneficial interest under a land trust may be subject to real estate transfer taxes levied by the Village of Mount Prospect and is subject to prior approval by the Director of Finance, whose office will check if there are any unresolved violations of the property maintenance code. Water and sewer bills must be paid; violations of property maintenance code must be resolved; has local form, copy of Illinois declaration required. In the absence of such approval, the Recorder of Deeds is required by state law to refuse to record or register the instrument of conveyance or assignment. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 7 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 138 FIDELITY NATIONAL TITLE INSURANCE COMPANY SCHEDULE B, PART I REQUIREMENTS (continued) COMMITMENT NO. FCH12000834LI 25. If it is desired that the General Exceptions be deleted for the policy to be issued, we should be furnished with a current plat of survey certified to the Company and made in accordance with the requirements jointly developed and adopted by the American Land Title Association (ALTA) and the National Society of Professional Surveyors (NSPS). END OF SCHEDULE B, PART I This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. ANM FD„i E The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 8 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 139 FIDELITY NATIONAL TITLE INSURANCE COMPANY SCHEDULE B, PART II EXCEPTIONS COMMITMENT NO. FCH12000834LI THIS COMMITMENT DOES NOT REPUBLISH ANY COVENANT, CONDITION, RESTRICTION, OR LIMITATION CONTAINED IN ANY DOCUMENT REFERRED TO IN THIS COMMITMENT TO THE EXTENT THAT THE SPECIFIC COVENANT, CONDITION, RESTRICTION, OR LIMITATION VIOLATES STATE OR FEDERAL LAW BASED ON RACE, COLOR, RELIGION, SEX, SEXUAL ORIENTATION, GENDER IDENTITY, HANDICAP, FAMILIAL STATUS, OR NATIONAL ORIGIN. The Policy will not insure against loss or damage resulting from the terms and provisions of any lease or easement identified in Schedule A, and will include the following Exceptions unless cleared to the satisfaction of the Company: General Exceptions Rights or claims of parties in possession not shown by Public Records. 2. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the title that would be disclosed by an accurate and complete land survey of the Land. 3. Easements, or claims of easements, not shown by the Public Records. 4. Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5. Taxes or special assessments which are not shown as existing liens by the Public Records. 6. Any defect, lien, encumbrance, adverse claim, or other matter that appears for the first time in the Public Records or is created, attaches, or is disclosed between the Commitment Date and the date on which all of the Schedule B, Part I—Requirements are met. A 7. Taxes for the year(s) 2020 and 2021. 2021 taxes are not yet due or payable. Note: 2020 first installment was due March 2, 2021. Note: 2020 final installment not yet billed, due or payable. Perm tax# Pcl Year 1st Inst Stat 08-23-100-018-0000 1 of 3 2020 $862,939.62 Paid 08-23-200-052-0000 2 & 3 of 3 2020 $76,105.99 Paid B 8. Memorandum of Lease of Space Agreement made by and between United Air Lines, Inc. (Landlord) to Chicago SMSA Limited Partnership (Tenant) dated January 12, 1996 and recorded January 30, 1996 as Document No. 96079013, demising a portion of the Land described therein for a term of years beginning This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. ANM FD„i E The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 9 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 140 FIDELITY NATIONAL TITLE INSURANCE COMPANY SCHEDULE B, PART II EXCEPTIONS (continued) COMMITMENT NO. FCH12000834LI December 18, 1995 and ending December 17, 2000, and all rights thereunder, as tenant only. Note: Provides that the original lease term will be automatically extended for four (4) successive five (5) year terms unless affirmatively cancelled. Also provides that after said extensions the lease automatically extends for successive one year terms if neither party terminates. Note: We should be furnished with a statement in writing as to the status of this lease. (Affects the Land and and other property not now in question.) C 9. INTENTIONALLY DELETED. D 10. Notice of Requirements for Storm Water Detention dated November 25, 1986 and recorded December 18, 1986 as Document No. 86607473, whereby United Airlines agrees to provide for proper storm water detention in accordance with the rules and regulations of the Metropolitan Water Reclamation District of Greater Chicago, f/k/a Metropolitan Sanitary District of Greater Chicago. Said Notice is not to be withdrawn, rescinded, or removed except after the MSDGC Requirements have been satisfied and a written release from the obligations obtained form the MSDGC. (Affects land and other property.) E 11. INTENTIONALLY DELETED. G 12. Terms and provisions of Ordinance No. 6297 Annexing certain property to the Village of Mount Prospect, recorded January 27, 2017 as Document No. 1702729006. Also zones said property to L-1 Limited Industrial District and acknowledges that United Airlines, Inc. may use part of the property for temporary overnight accomodations for employees, etc. as a legal non -conforming use. (Affects Parcel 1) 13. INTENTIONALLY DELETED. K 14. INTENTIONALLY DELETED. L 15. INTENTIONALLY DELETED. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. ANM FD„i E The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 10 IL -FT -FILL -03000.233208 -SPS -1 -21 -FCH12000834LI 141 FIDELITY NATIONAL TITLE INSURANCE COMPANY SCHEDULE B, PART II EXCEPTIONS (continued) COMMITMENT NO. FCH12000834LI M 16. INTENTIONALLY DELETED. N 17. Existing unrecorded leases and all rights thereunder of the lessees and of any person or party claiming by, through or under the lessees. F 18. Ordinance Approving a Plat of Annexation to the Village of Mount Prospect for a Portion of Linneman Road Located South of and Adjoining Dempster Street recorded May 24 2007 as Document No. 0714422107. H 19. Ordinance Approving a Plat of Annexation to the Village of Mount Prospect for a Portion of Dempster Street and Algonquin Road recorded August 8, 2016 as Document No. 1622129105. J 20. Village of Mount Prospect Ordinance No. 6296 annexing certain property to the Village of Mount Prospect recorded January 27, 2017 as Document No. 1702729005 and zoning said property as 1-1 Limited Industrial District. (Affects Parcels 2 and 3) O 21. Terms and provisions of Memorandum of Purchase and Sale Agreement between United Airlines,lnc. (Seller) and CloudHQ, LLC (Purchaser) recorded June 23, 2021 as Document No. 2117422029. See document for expiration provision. END OF SCHEDULE B, PART II This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. ANM FD„i E The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 11 IL -FT -FILL -03000.233208 -SPS -1 -21 -FCH12000834LI 142 FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. FCH12000834LI COMMITMENT CONDITIONS 1. DEFINITIONS (a) "Knowledge" or "Known": Actual or imputed knowledge, but not constructive notice imparted by the Public Records. (b) "Land": The land described in Schedule A and affixed improvements that by law constitute real property. The term "Land" does not include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (c) "Mortgage": A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law. (d) "Policy": Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (e) "Proposed Insured": Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment. (f) "Proposed Policy Amount": Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (g) "Public Records": Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (h) "Title": The estate or interest described in Schedule A. 2. If all of the Schedule B, Part I -Requirements have not been met within the time period specified in the Commitment to Issue Policy, this Commitment terminates and the Company's liability and obligation end. 3. The Company's liability and obligation is limited by and this Commitment is not valid without: (a) the Notice; (b) the Commitment to Issue Policy; (c) the Commitment Conditions; (d) Schedule A; (e) Schedule B, Part I -Requirements; (f) Schedule B, Part II -Exceptions; and (g) a counter -signature by the Company or its issuing agent that may be in electronic form. 4. COMPANY'S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY (a) The Company's liability under Commitment Condition 4 is limited to the Proposed Insured's actual expense incurred in the interval between the Company's delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured's good faith reliance to: (i) comply with the Schedule B, Part I -Requirements; (ii) eliminate, with the Company's written consent, any Schedule B, Part II -Exceptions; or (iii) acquire the Title or create the Mortgage covered by this Commitment. (b) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (c) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (d) The Company's liability shall not exceed the lesser of the Proposed Insured's actual expense incurred in good faith and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. (e) The Company shall not be liable for the content of the Transaction Identification Data, if any. (f) In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I -Requirements have been met to the satisfaction of the Company. (g) In any event, the Company's liability is limited by the terms and provisions of the Policy. 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT (a) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment. (b) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 12 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 143 FIDELITY NATIONAL TITLE INSURANCE COMPANY COMMITMENT NO. FCH12000834LI (continued) (c) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (d) The deletion or modification of any Schedule B, Part II -Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (e) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company. (f) When the Policy is issued, all liability and obligation under this Commitment will end and the Company's only liability will be under the Policy. 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company's agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company's agent for the purpose of providing closing or settlement services. 8. PRO -FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro -forma policy illustrating the coverage that the Company may provide. A pro -forma policy neither reflects the status of Title at the time that the pro -forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is Two Million And No/100 Dollars ($2,000,000.00) or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at htto://www.alta.org/arbitration. END OF CONDITIONS 1031 EXCHANGE SERVICES If your transaction involves a tax deferred exchange, we offer this service through our 1031 division, IPX1031. As the nation's largest 1031 company, IPX1031 offers guidance and expertise. Security for Exchange funds includes segregated bank accounts and a 100 million dollar Fidelity Bond. Fidelity National Title Group also provides a 50 million dollar Performance Guaranty for each Exchange. For additional information, or to set-up an Exchange, please call Scott Nathanson at (312)223-2178 or Anna Barsky at (312)223-2169. This page is only apart of a 2016 ALTA® Commitment for Title Insurance issued by Fidelity National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I -Requirements; Schedule B, Part 11 -Exceptions; and a counter -signature by the Company or its issuing agent that may be in electronic form. Copyright American Land Title Association. All rights reserved. AND CAN The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. ALTA Commitment for Title Insurance (08/01/2016) Printed: 08.06.21 @ 03:44 PM Page 13 IL-FT-FILL-03000.233208-SPS-1-21-FCH12000834LI 144 I.... Inquire before you wire! WIRE FRAUD ALERT This Notice is not intended to provide legal or professional advice. If you have any questions, please consult with a lawyer. All parties to a real estate transaction are targets for wire fraud and many have lost hundreds of thousands of dollars because they simply relied on the wire instructions received via email, without further verification. If funds are to be wired in conjunction with this real estate transaction, we strongly recommend verbal verification of wire instructions through a known, trusted phone number prior to sending funds. In addition, the following non-exclusive self-protection strategies are recommended to minimize exposure to possible wire fraud. • NEVER RELY on emails purporting to change wire instructions. Parties to a transaction rarely change wire instructions in the course of a transaction. • ALWAYS VERIFY wire instructions, specifically the ABA routing number and account number, by calling the party who sent the instructions to you. DO NOT use the phone number provided in the email containing the instructions, use phone numbers you have called before or can otherwise verify. Obtain the number of relevant parties to the transaction as soon as an escrow account is opened. DO NOT send an email to verify as the email address may be incorrect or the email may be intercepted by the fraudster. • USE COMPLEX EMAIL PASSWORDS that employ a combination of mixed case, numbers, and symbols. Make your passwords greater than eight (8) characters. Also, change your password often and do NOT reuse the same password for other online accounts. • USE MULTI -FACTOR AUTHENTICATION for email accounts. Your email provider or IT staff may have specific instructions on how to implement this feature. For more information on wire -fraud scams or to report an incident, please refer to the following links: Federal Bureau of Investigation: http://www.fbi..qov Wire Fraud Alert Original Effective Date: 5/11/2017 Current Version Date: 5/11/2017 Internet Crime Complaint Center: http://www. ic3.gov Page 14 FCH12000834LI - WIRE0016 (DSI Rev. 12/07/17) TM and © Fidelity National Financial, Inc. and/or an affiliate. All rights reserved 145 FIDELITY NATIONAL FINANCIAL PRIVACY NOTICE Effective January 1, 2021 Fidelity National Financial, Inc. and its majority-owned subsidiary companies (collectively, "FNF," "our," or "we") respect and are committed to protecting your privacy. This Privacy Notice explains how we collect, use, and protect personal information, when and to whom we disclose such information, and the choices you have about the use and disclosure of that information. A limited number of FNF subsidiaries have their own privacy notices. If a subsidiary has its own privacy notice, the privacy notice will be available on the subsidiary's website and this Privacy Notice does not apply. Collection of Personal Information FNF may collect the following categories of Personal Information: • contact information (e.g., name, address, phone number, email address); • demographic information (e.g., date of birth, gender, marital status); • identity information (e.g. Social Security Number, driver's license, passport, or other government ID number); • financial account information (e.g. loan or bank account information); and • other personal information necessary to provide products or services to you. We may collect Personal Information about you from: • information we receive from you or your agent; • information about your transactions with FNF, our affiliates, or others; and • information we receive from consumer reporting agencies and/or governmental entities, either directly from these entities or through others. Collection of Browsing Information FNF automatically collects the following types of Browsing Information when you access an FNF website, online service, or application (each an "FNF Website") from your Internet browser, computer, and/or device: • Internet Protocol (IP) address and operating system; • browser version, language, and type; • domain name system requests; and • browsing history on the FNF Website, such as date and time of your visit to the FNF Website and visits to the pages within the FNF Website. Like most websites, our servers automatically log each visitor to the FNF Website and may collect the Browsing Information described above. We use Browsing Information for system administration, troubleshooting, fraud investigation, and to improve our websites. Browsing Information generally does not reveal anything personal about you, though if you have created a user account for an FNF Website and are logged into that account, the FNF Website may be able to link certain browsing activity to your user account. Other Online Specifics Cookies. When you visit an FNF Website, a "cookie" may be sent to your computer. A cookie is a small piece of data that is sent to your Internet browser from a web server and stored on your computer's hard drive. Information gathered using cookies helps us improve your user experience. For example, a cookie can help the website load properly or can customize the display page based on your browser type and user preferences. You can choose whether or not to accept cookies by changing your Internet browser settings. Be aware that doing so may impair or limit some functionality of the FNF Website. Web Beacons. We use web beacons to determine when and how many times a page has been viewed. This information is used to improve our websites. Do Not Track. Currently our FNF Websites do not respond to "Do Not Track" features enabled through your browser. Privacy Statement Printed: 08.06.21 @ 03:44 PM by SSCORPDO911.doc Page 15 IL-FT-FILL-03000.233208-FCH12000834LI `El N Links to Other Sites. FNF Websites may contain links to unaffiliated third -party websites. FNF is not responsible for the privacy practices or content of those websites. We recommend that you read the privacy policy of every website you visit. Use of Personal Information FNF uses Personal Information for three main purposes: • To provide products and services to you or in connection with a transaction involving you. • To improve our products and services. • To communicate with you about our, our affiliates', and others' products and services, jointly or independently. When Information Is Disclosed We may disclose your Personal Information and Browsing Information in the following circumstances: • to enable us to detect or prevent criminal activity, fraud, material misrepresentation, or nondisclosure; • to nonaffiliated service providers who provide or perform services or functions on our behalf and who agree to use the information only to provide such services or functions; • to nonaffiliated third party service providers with whom we perform joint marketing, pursuant to an agreement with them to jointly market financial products or services to you; • to law enforcement or authorities in connection with an investigation, or in response to a subpoena or court order; or • in the good -faith belief that such disclosure is necessary to comply with legal process or applicable laws, or to protect the rights, property, or safety of FNF, its customers, or the public. The law does not require your prior authorization and does not allow you to restrict the disclosures described above. Additionally, we may disclose your information to third parties for whom you have given us authorization or consent to make such disclosure. We do not otherwise share your Personal Information or Browsing Information with nonaffiliated third parties, except as required or permitted by law. We may share your Personal Information with affiliates (other companies owned by FNF) to directly market to you. Please see "Choices with Your Information" to learn how to restrict that sharing. We reserve the right to transfer your Personal Information, Browsing Information, and any other information, in connection with the sale or other disposition of all or part of the FNF business and/or assets, or in the event of bankruptcy, reorganization, insolvency, receivership, or an assignment for the benefit of creditors. By submitting Personal Information and/or Browsing Information to FNF, you expressly agree and consent to the use and/or transfer of the foregoing information in connection with any of the above described proceedings. Security of Your Information We maintain physical, electronic, and procedural safeguards to protect your Personal Information. Choices With Your Information If you do not want FNF to share your information among our affiliates to directly market to you, you may send an "opt out" request as directed at the end of this Privacy Notice. We do not share your Personal Information with nonaffiliates for their use to direct market to you without your consent. Whether you submit Personal Information or Browsing Information to FNF is entirely up to you. If you decide not to submit Personal Information or Browsing Information, FNF may not be able to provide certain services or products to you. For California Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties, except as permitted by California law. For additional information about your California privacy rights, please visit the "California Privacy" link on our website (htti)s://fnf.com/pages/californiai)rivacy.asl)x) or call (888) 413-1748. For Nevada Residents: You may be placed on our internal Do Not Call List by calling (888) 934-3354 or by contacting us via the information set forth at the end of this Privacy Notice. Nevada law requires that we also provide you with the following contact information: Bureau of Consumer Protection, Office of the Nevada Attorney General, 555 E. Washington St., Suite 3900, Las Vegas, NV 89101; Phone number: (702) 486-3132; email: BCPINFO@ag.state.nv.us. Privacy Statement Printed: 08.06.21 @ 03:44 PM by SSCORPDO911.doc Page 16 IL-FT-FILL-03000.233208-FCH12000834LI 147 For Oregon Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties for marketing purposes, except after you have been informed by us of such sharing and had an opportunity to indicate that you do not want a disclosure made for marketing purposes. For Vermont Residents: We will not disclose information about your creditworthiness to our affiliates and will not disclose your personal information, financial information, credit report, or health information to nonaffiliated third parties to market to you, other than as permitted by Vermont law, unless you authorize us to make those disclosures. Information From Children The FNF Websites are not intended or designed to attract persons under the age of eighteen (18). We do not collect Personal Information from any person that we know to be under the age of thirteen (13) without permission from a parent or guardian. International Users FNF's headquarters is located within the United States. If you reside outside the United States and choose to provide Personal Information or Browsing Information to us, please note that we may transfer that information outside of your country of residence. By providing FNF with your Personal Information and/or Browsing Information, you consent to our collection, transfer, and use of such information in accordance with this Privacy Notice. FNF Website Services for Mortgage Loans Certain FNF companies provide services to mortgage loan servicers, including hosting websites that collect customer information on behalf of mortgage loan servicers (the "Service Websites"). The Service Websites may contain links to both this Privacy Notice and the mortgage loan servicer or lender's privacy notice. The sections of this Privacy Notice titled When Information is Disclosed, Choices with Your Information, and Accessing and Correcting Information do not apply to the Service Websites. The mortgage loan servicer or lender's privacy notice governs use, disclosure, and access to your Personal Information. FNF does not share Personal Information collected through the Service Websites, except as required or authorized by contract with the mortgage loan servicer or lender, or as required by law or in the good -faith belief that such disclosure is necessary: to comply with a legal process or applicable law, to enforce this Privacy Notice, or to protect the rights, property, or safety of FNF or the public. Your Consent To This Privacy Notice; Notice Changes; Use of Comments or Feedback By submitting Personal Information and/or Browsing Information to FNF, you consent to the collection and use of the information in accordance with this Privacy Notice. We may change this Privacy Notice at any time. The Privacy Notice's effective date will show the last date changes were made. If you provide information to us following any change of the Privacy Notice, that signifies your assent to and acceptance of the changes to the Privacy Notice. Accessinq and Correctinq Information; Contact Us If you have questions, would like to correct your Personal Information, or want to opt -out of information sharing for affiliate marketing, visit FNF's Opt Out Page or contact us by phone at (888) 934-3354 or by mail to: Fidelity National Financial, Inc. 601 Riverside Avenue, Jacksonville, Florida 32204 Attn: Chief Privacy Officer Privacy Statement Printed: 08.06.21 @ 03:44 PM by SSCORPDO911.doc Page 17 IL-FT-FILL-03000.233208-FCH12000834LI 148 ` The First Installment amount is 55% of last year's total taxes. All exemptions, such as homeowner and senior exemptions, will be reflected oil your Second Installment tax bill. 1200EALGQNQUINRD UNITED AIRLINES INC MOUNT PRD5PECT|L60O5G 333 SVYACKERDRHDQCT CHICAGO IL 60606-7147 DETACH &/wcmopwnxpw�swn — ---------- -- --- --- - Property -index Number (PIN) — 149 08-23-100-018-0000 050 380984 I f' 11RIMMIZ312333M 2020 First Installment Property Tax $ 862t939.62 Property Index Number (PIN) Volurne Code Tax Year (Payable In) Township Classification 08-23-100-018-0000 050 16081 2020 2021 ELK GROVE 5-91 By 03/02121 (on time) 03/02/21, PLEA$E PAY $862,939.62 $862,939.62 $875,883.71 Pension and Amount of % of Pansion and Money Owed by Healthcare Amounts Pension and Healthcare Costs Your Taxing Promised by Your Healthcare Taxing Districts Your Taxing Districts Districts Taxing Districts Shortage Can Pay Northwest Mosquito Abatement Wheeling $213,887 $7,369,108 $526,648 92.85% Metro Water Reclamation Dist of Chicago $3,404,722,000 $2,909,890,000 $1,377,581,000 52.66% - Harper Coll Comm College 512 (Palatine) $236,394,131 $72,977,857 $72,977,857 0.00% Township HS District 214 (Arlington Hts) $183,832,610 $266,729,952 $19,482,369 92.70% Comm Consolidated SD 59 (Arlington Hts) $7,151,769 $149,740,035 $16,206,881 89.18% Village of Mount Prospect $179,253,333 $353,228,504 $111,666,629 68.39% Town of Elk Grove $746,354 $6,277,689 -$297,245 104.73% Cook County Forest Preserve District $193,646,842 $457,040,680 $246,669,734 46.03% County of Cook $6,898,027,070 $23,257,290,307 $13,395,266,525 42.40% Total $11,124,772,270 $27,511,441,337 $15,246,193,556 ` The First Installment amount is 55% of last year's total taxes. All exemptions, such as homeowner and senior exemptions, will be reflected oil your Second Installment tax bill. 1200EALGQNQUINRD UNITED AIRLINES INC MOUNT PRD5PECT|L60O5G 333 SVYACKERDRHDQCT CHICAGO IL 60606-7147 DETACH &/wcmopwnxpw�swn — ---------- -- --- --- - Property -index Number (PIN) — 149 08-23-100-018-0000 050 380985 1 of' 2020 ZVIV I V I AL I AA a I 't . Z)Zo 2020 ESTIMATE X 55% 2020 TOTAL TAX 76,105.99 The First Installment amount is 554 of last year's total taxes. All exemptions, such as homeowner and senior exemptions, will be reflected on your Second Installment tax bill. DETACH & INCLUDE WITH PAYMENT Property Index Number (PIN) VolTI 150 NIMEMSE23M EZEEMEMEMECME=08-23-200-052-0000 050 Use of this coupon authorizes the Treasurer's Office to Amount Paid it Installment Property Tax Bill $76,105.99 Property Index Number (PIN) Volume Code Tax Year (Payable In) Township Classification 08-23-200-052-0000 050 16081 2020 2021 ELK GROVE 5-80 By 03/02/21 (on time) IF PAYING AFTER 03/03/21- 04/01/21 04/02/21- 05/03/21 05/04/21- OR 06/01/21 03/02/21, PLEASE PAY $76,105.99 OR $76,10$.99 $77,247.58 Pension and Amount of % of Pension and Money Owed by Healthcare Amounts Pension and Healthcare Costs Your Taxing Promised by Your Healthcare Taxing Districts Your Taxing Districts Districts Taxing Districts Shortage Can Pay Northwest Mosquito Abatement Wheeling $213,887 $7,369,108 $526,648 92.85% Metro Water Reclamation Dist of Chicago $3,404,722,000 $2,909,890,000 $1,377,581,000 52.66% -,Mt - Prospect 11 Park I I District $20,784,274 $30,897,206 $6,113,158 80.21% Harper Coll Comm College 512 (Palatine) $236,394,131 $72,977,857 $72,977,857 0.001yo Township HS District 214 (Arlington His) $183,832,610 $266,729,952 $19,482,369 92,70% Comm Consolidated SD 59 (Arlington Hts) $7,151,769 $149,740,035 $16,206,881 89.18% Village of Mount Prospect $179,253,333 $353,228,504 $111,666,629 68.3911/0 Town of Elk Grove $746,3$4 $6,277,689 -$297,245 104.73% Cook County Forest Preserve District $193,646,842 $457,040,680 $246,669,734 46.03% County of Cook $6,898,027,070 $23,257,290,307 $13,395,266,525 42.40% Total $11,124,772,270 $27,511,441,337 $15,246,193,556 ZVIV I V I AL I AA a I 't . Z)Zo 2020 ESTIMATE X 55% 2020 TOTAL TAX 76,105.99 The First Installment amount is 554 of last year's total taxes. All exemptions, such as homeowner and senior exemptions, will be reflected on your Second Installment tax bill. DETACH & INCLUDE WITH PAYMENT Property Index Number (PIN) VolTI 150 NIMEMSE23M EZEEMEMEMECME=08-23-200-052-0000 050 Use of this coupon authorizes the Treasurer's Office to Amount Paid Cook County Treasurer - Property Tax Payment https://www.payconnexion.com/pconWeb/public/payment/confirmPaym... Payment Confirmation - Cook County Property Tax Payment may be withdrawn from your account as soon as tomorrow or the next banking business day. It is important that you have money in your bank account to cover this payment. Thank you for using the Cook County Treasurer Property Tax electronic payment system. Please keep a record of your Confirmation Number, or print this page for your records. Confirmation Number: cc'rP'rXO04!532704 Confirmation Date (CT): May 0:3 •2023. 06A.5:11.0 AM Your Payment Detail Payment Amount: $76,105 99 Bill Year: 2020 Property Index Number (PIN): 08 23 200-052 0000 Volume: 050 Property Location: 1.200 111) 111.: M IIISIIIIII..! R ST Ili 31U1W"III" 1ICT, 11 60056 0000 Mailing Address: 233 S WACKER DR IIIlDQCT CHICAGO, V 60606 71.47 Balance Due: $76,105.99 Tax Type: 0 Tax Year: 2020 Bank Routing Number: 07100001.3 Bank Account Number: XXXXXXX9tXXXXX7218 Bank Account Type: Checkiing Bank Account Category: Busilness E-mail Address*: propertyltax@unfted com Please keep a record of your Confirmation Number, or anrLt this page for your records. 151 1 of 1 5/3/2021, 6:15 AM Cook County Treasurer - Property Tax Payment https://www.payconnexion.com/pconWeb/public/payment/confirmPaym... Payment Confirmation - Cook County Property Tax Payment may be withdrawn from your account as soon as tomorrow or the next banking business day. It is important that you have money in your bank account to cover this payment. Thank you for using the Cook County Treasurer Property Tax electronic payment system. Please keep a record of your Confirmation Number, or print this page for your records. Confirmation Number: cc'rP'rXO04!532686 Confirmation Date (CT): May 0:3 •2023. 06:011.:38 AM Your Payment Detail Payment Amount: $862,939 62 Bill Year: 2020 Property Index Number (PIN): 08 23 1.00-01.8 0000 Volume: 050 Property Location: 1.200 111.: All GONQUIN IRD MOUN'r PRosil,,iil..�vl', lIt 60056 0000 Mailing Address: 233 S WACKER DR IIIlDQCT CHICAGO, V 60606 71.47 Balance Due: $862,9:39.62 Tax Type: 0 Tax Year: 2020 Bank Routing Number: 07100001.3 Bank Account Number: XXXXXXX9tXXXXX7218 Bank Account Type: Checkiing Bank Account Category: Busilness E-mail Address*: propertyltax@unfted com Please keep a record of your Confirmation Number, or anrLt this page for your records. 152 1 of 1 5/3/2021, 6:01 AM $76,167.38 By 10/01/2021 IF PAYING LATE, PLEASE PAY Taxing Districts 2020 Second Installment Property Tax Bill - Cook County Electronic Bill Property Index Number (PIN) Volume Code Tax Year (Payable In) Township Classification 08-23-200-052-0000 050 16081 2020 (2021) ELK GROVE 5-80 10/02/2021 - 11/01/2021 11/02/2021-12/01/2021 12/02/2021-01/01/2022 LATE INTEREST IS 1.5% PER $77,309.89 $78,452.40 $79,594.91 MONTH, BY STATE LAW ®IF®® 2020 Tax 2020 Rate 2020% Pension 2019 Tax MISCELLANEOUS TAXES 2020 Total Tax Before Exemptions 152,273.37 Homeowner's Exemption .00 Northwest Mosq Abatement Dist Wheeling 176.51 0.010 0.12% 2020 State Equalizer X 3.2234 159.68 Metro Water Reclamation Dist of Chicago 6,672.00 0.378 4.38% 741.33 6,211.37 Mt Prospect Park District 9,778.54 0.554 6.42% 917.84 8,734.23 Miscellaneous Taxes Total 16,627.05 0.942 10.92% 15,105.28 SCHOOL TAXES Harper College Comm College 512 Palatine 7,219.17 0.409 4.74% 6,434.91 Township HS District 214 (Arlington Hts) 42,044.18 2.382 27.61% 1,500.31 37,619.48 Community Consolid. SD 59 Arlington Hts 48,274.91 2.735 31.70% 1,482.66 43,926.65 School Taxes Total 97,538.26 5.526 64.05% 87,981.04 MUNICIPALITY/TOWNSHIP TAXES Mount Prospect Library Fund 10,466.92 0.593 6.87% 9,564.54 Village of Mount Prospect 17,262.47 0.978 11.34% 6,442.53 15,775.91 Road & Bridge Elk Grove 229.46 0.013 0.15% 223.55 General Assistance Elk Grove 194.16 0.011 0.13% 175.64 Town of Elk Grove 935.49 0.053 0.61% 878.21 Municipality/Township Taxes Total 29,088.50 1.648 19.10% 26,617.85 COOK COUNTY TAXES Cook County Forest Preserve District 1,023.75 0.058 0.67% 35.30 942.08 Consolidated Elections 0.00 0.000 0.00% 479.03 County of Cook 4,801.02 0.272 3.16% 1,535.61 4,391.06 Cook County Public Safety 2,329.90 0.132 1.53% 2,139.65 Cook County Health Facilities 864.89 0.049 0.57% 718.54 Cook County Taxes Total 9,019.56 0.511 5.93% 8,670.36 (Do not pay these totals) 152,273.37 8.627 100.00% 138,374.53 2019 Assessed Value 547,583 2020 Total Tax Before Exemptions 152,273.37 Homeowner's Exemption .00 Senior Citizen Exemption .00 2020 Assessed Value 547,583 Senior Freeze Exemption .00 2020 State Equalizer X 3.2234 2020 Equalized Assessed Value (EAV) 2020 Total Tax After Exemptions 1,765,079 152,273.37 2020 Local Tax Rate X 8.627% First Installment 76,105.99 2020 Total Tax Before Exemptions Second Installment + 76,167.38 152,273.37 Total 2020 Tax (Payable in 2021) 152,273.37 UNITED AIRLINES INC 1200 DEMPSTER ST 233 S WACKER DR HDQCT MOUNT PROSPECT IL 60056 0000 CHICAGO IL 606067147 *** Please see 2020 Second Installment Payment Coupon next page *** 153 I 2020 Second Installment Property Tax Bill - Cook County Electronic Bill 2020 Total Tax Before Exemptions $863,635.64 Property Index Number (PIN) Volume Code Tax Year (Payable In) Township Classification By 10101/2021 2020 Assessed Value 6,208,855 Senior Freeze Exemption .00 2020 State Equalizer X 3.2234 2020 Equalized Assessed Value (EAV) 08-23-100-018-0000 050 16081 2020 (2021) ELK GROVE 5-91 IF PAYING LATE, 10/02/2021 - 11/01/2021 11/02/2021-12/01/2021 First Installment 862,939.62 12/02/2021-01/01/2022 Second Installment + 863,635.64 LATE INTEREST IS 1.5% PER PLEASE PAY $876,590.17 $889,544.70 1,726,575.26 $902,499.23 MONTH, BY STATE LAW Taxing Districts 2020 Tax 2020 Rate 2020% Pension 2019 Tax MISCELLANEOUS TAXES Northwest Mosq Abatement Dist Wheeling 2,001.36 0.010 0.12% 1,810.50 Metro Water Reclamation Dist of Chicago 75,651.49 0.378 4.38% 8,405.72 70,428.53 Mt Prospect Park District 110,875.47 0.554 6.42% 10,407.08 99,034.46 Miscellaneous Taxes Total 188,528.32 0.942 10.92% 171,273.49 SCHOOL TAXES Harper College Comm College 512 Palatine 81,855.72 0.409 4.74% 72,963.23 Township HS District 214 (Arlington Hts) 476,724.50 2.382 27.61% 17,011.57 426,554.29 Community Consolid. SD 59 Arlington Hts 547,372.59 2.735 31.70% 16,811.44 498,069.13 School Taxes Total 1,105,952.81 5.526 64.05% 997,586.65 MUNICIPALITY/TOWNSHIP TAXES Mount Prospect Library Fund 118,680.78 0.593 6.87% 108,449.08 Village of Mount Prospect 195,733.23 0.978 11.34% 73,049.72 178,877.61 Road & Bridge Elk Grove 2,601.77 0.013 0.15% 2,534.70 General Assistance Elk Grove 2,201.50 0.011 0.13% 1,991.55 Town of Elk Grove 10,607.22 0.053 0.61% 9,957.76 Municipality/Township Taxes Total 329,824.50 1.648 19.10% 301,810.70 COOK COUNTY TAXES Cook County Forest Preserve District 11,607.90 0.058 0.67% 400.27 10,681.96 Consolidated Elections 0.00 0.000 0.00% 5,431.51 County of Cook 54,437.07 0.272 3.16% 17,411.85 49,788.82 Cook County Public Safety 26,417.98 0.132 1.53% 24,260.73 Cook County Health Facilities 9,806.68 0.049 0.57% 8,147.26 Cook County Taxes Total 102,269.63 0.511 5.93% 98,310.28 (Do not pay these totals) 1,726,575.26 8.627 100.00% 1,568,981.12 2019 Assessed Value 6,208,855 2020 Total Tax Before Exemptions 1,726,575.26 Homeowner's Exemption .00 Senior Citizen Exemption .00 2020 Assessed Value 6,208,855 Senior Freeze Exemption .00 2020 State Equalizer X 3.2234 2020 Equalized Assessed Value (EAV) 2020 Total Tax After Exemptions 20,013,623 1,726,575.26 2020 Local Tax Rate X 8.627% First Installment 862,939.62 2020 Total Tax Before Exemptions Second Installment + 863,635.64 1,726,575.26 Total 2020 Tax (Payable in 2021) 1,726,575.26 UNITED AIRLINES INC 1200 E ALGONQUIN RD 233 S WACKER DR HDQCT MOUNT PROSPECT IL 60056 0000 CHICAGO IL 606067147 *** Please see 2020 Second Installment Payment Coupon next page *** 154 Payment Confirmation - Cook County Property Tax Payment may be withdrawn from your account as soon as tomorrow or the next banking business day. It is important that you have money in your bank account to cover this payment. Thank you for using the Cook County Treasurer Property Tax electronic payment system. ............................................................................................................................................................................................................................................................................................................................................................ Please keep a record of your Confirmation Number, or print this page for your records. ITEO confirmation INu.unnilbein CC"'riip: rxo04837723 Confirmation II)ate (C'i); Selp,,,,,282021. 'I. 0 :38::36 AII14 Your Payment Detail Payment amouint$76,:167.38 Bill Year 02,0 Property Index Number (Ii'III 08 ,,,, 3,,, 00,,,,0'5'2,,,,0000 Volume 050 Property I....ocatioin, 1,200 IIM!!!III IIS "'rillElllt s"'I" III IIsi III"' III iiRosiII:,II;.:.c ", IIIb,,, 60056 0000 MaMng address 1233CIII III!!!'�IIGI III)IIR IIIMIII: C"'I" CIII, 1111 60606 7 14. Ballance I[aue° $76,167,I .Fax ..Type 0 .lax Year 2020 Your Account Detail II Routing INumber 07:10000:13 Bank account Number:: 'I. Bank Account Type Clhecllkliin Bank account Category IlIss IF irmmaiillAddress*:: Ilpiii-ollpeiirtytax@uiiriliited coirn Please keep a record of your Confirmation Number, or print this page for your records. ITEO 155